alternator RENAULT TWINGO 2009 2.G Electrical Equipment - Petrol Injection Workshop Manual

Page 26 of 348

17B-26V7 MR-413-X44-17B000$060.mif
PETROL INJECTION
Fault finding – Features17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
Air conditioning function
The SIM32 computer manages a "Cold Loop" type air conditioning system:
–request for air conditioning by logical link,
–acquisition of pressure in the air conditioning circuit,
–vehicle speed
–air conditioning compressor control,
–fan unit control for the requirements of this function.
The injection computer reconstitutes the power absorbed by the air conditioning compressor and fast idle speed
requests by using the pressure acquired in the air conditioning circuit.
These signals are necessary for adapting the engine management (idling speed regulation, air flow correction, etc.),
for several reasons:
–air conditioning compressor efficiency,
–more engine ruggedness due to torque hesitation caused by the compressor clutching and declutching,
–helping the alternator.
Fan unit 1 and/or 2 requests are reconstituted according to the pressure in the air conditioning circuit and the vehicle
speed. In summary, there are more fan unit requests when the speed is low and the pressure is high.
OCS - Customised Oil Change Interval (does not concern Vdiag 44 and 4C).
This program takes into account the driving style of the user to warn him of the need for an oil service. It counts the
number of revs per minute since the last oil service, corrected by a factor dependent on the oil temperature. When
this number of revs per minute exceeds a certain threshold, the customer is alerted by a message on the instrument
panel informing him that an oil service is required.
After the oil service, the user must reset the oil service interval on the instrument panel.
To find out if the engine concerned uses this programming, consult ET840 Customised Oil Change Interval.
OBD
The OBD programs are as follows:
–catalytic converter fault finding,
–upstream sensor operational fault finding,
–misfire fault finding,
–fuel supply system fault finding.
The misfiring and fuel supply system fault finding is performed continuously. The operational fault finding for the
upstream sensor and the catalytic converter can be only be carried out once per journey, and can never take place
at the same time.

Page 29 of 348

17B-29V7 MR-413-X44-17B000$070.mif
PETROL INJECTION
Fault finding – Role of components17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
3. INTERSYSTEM ENGINE FUNCTIONS
The intersystem connections relating to the particular requirements of the injection are as follows:
–The instrument panel computer requests illumination of the OBD warning light to warn of an emissions control fault.
–Requests illumination of the Severity level 1 warning light to warn of an operational safety fault related to the
injection system.
–Requests illumination of the Severity level 2 warning light to warn of an operational safety fault or engine
overheating.
–Requests activation of the fan assemblies (GMV) for engine cooling, but also for the air conditioning system and
sequential gearbox (BVR) functions.
–Request for air conditioning compressor switch-off for engine programming requirements such as starting,
performance, anti-stall, overspeed, etc.
–Passenger Compartment Heating Resistor cut-off or setting request for engine programming requirements such as
starting, performance, anti-stall, overspeed, etc.
–Request for gradual engagement of electrical consumers and to limit power: This last function is made possible by
the alternator being operated. This is used to improve the engine handling in critical operating phases, mainly when
idling and when starting. These requests are sent by the UCH via the CAN network where they are converted before
being sent to the alternator.

Page 114 of 348

17B-114V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF102
PRESENT
OR
STOREDALTERNATOR POWER SIGNAL AVAILABLE
1.DEF: Multiplex line connection fault
NOTESConditions for applying the fault finding procedure to stored faults
The fault is declared present when the ignition is switched on or with the engine running.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, check the insulation and continuity of the following connections:
For NEW TWINGO or E33:
●AP29 between components 120 and 1016,
●2N between components 645 and 103,
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
For Clio III and MODUS:
●AP between components 120 and 1337,
●2N between components 1337 and 103.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
SIM32_V44_DF102/SIM32_V4C_DF102/SIM32_V50_DF102/SIM32_V54_DF102
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.