CLIMATE CONTROL
Fault finding - Interpretation of faults
                            
Vdiag No.: 44
62B
DF021
PRESENT
OR
STORED RECIRCULATION MOTOR CIRCUIT
CO : Open circuit
CC.0 : Short circuit to earth
CC.1 : Short circuit to +  12 V
NOTESConditions for running fault finding on a present or stored fault:
The fault is declared present with the air conditioning panel on and the recirculation 
control activated (recirculation selected for flap closed or exterior air selected for flap 
open).
Special notes:
After repairing the fault (when the fault switches from present to stored), wait for 
1 minute before the climate control computer is able to control the distribution motor. 
To avoid having to wait for 1 minute, switch the ignition off and then back on again.
In extreme temperatures (above 35 ˚C) and when the climate control is switched on, 
the recirculation flap sets itself to the recirculation position in order to correct the 
passenger compartment temperature more quickly.
Use the Wiring Diagram Technical Note for the New Twingo.
Check the condition and connection of the connector of component 475.
If the connector is faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for the 
repair), repair the connector, otherwise replace the wiring.
With connector B of component 419 disconnected, check the insulation and continuity of the following 
connections between components 419 and 475:
●connection 38JA 
●connection 38JB 
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: 
Precautions for repair), repair the wiring, otherwise replace it.
Check the resistance of component 475 between connections 38JA and 38JB.
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: 
Precautions for repair), repair the wiring, otherwise replace it.
Replace the motor if the resistance is not: 35 ΩΩ Ω Ω
 ± 5 ΩΩ Ω Ω
 at 20 ˚C.
If the fault is still present, contact the Techline.
AFTER REPAIRClear the stored faults.
Follow the instructions to confirm repair.
If the motor has been replaced (see Configuration and programming).
Deal with any other faults.
CLIM_V44_DF021 
Page 32 of 99
62B-32
MR-413-X44-62B000$460_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - Conformity check
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine stopped with ignition on (12 V APC), AIR 
CONDITIONING OFF (air conditioning compressor not activated).
Note:
–Read the parameters when the vehicle is cold (in the morning) to check the 
conformity of the temperature parameters (without thermometer). The two 
temperatures should be practically the same (as should the coolant temperature 
given by the injection system).
–The invalid values given in this check correspond to the value sent by the diagnostic 
tool (substitute value) when the sensor in question is faulty. A sensor fault can be 
detected when these invalid values are displayed (this is an important point for 
sensors on which fault finding cannot be performed, e.g. exterior temperature 
sensor).
Delayed illumination of the exterior temperature sensor LCD indicates that an invalid 
value has been received concerning the exterior temperature sensor.
FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
Passenger 
compartment 
blowerET141:Passenger 
compartment 
blowerRUNNING 
or 
 STOPPED 
After a user requestIn the event of a fault, refer to the 
interpretation of this status.
PR019:Passenger 
compartment 
fan PWM settingSpeed 0 = 0 %
Speed 8 = 100 %
Note:
The PWM signal is a 
modulated control 
voltage used to control 
the air conditioning 
blower power module.If there is a fault or for more 
information (to find the 
intermediate speed 
percentages), refer to the 
interpretation of this 
parameter.
Note:
If the parameter varies correctly, 
but the passenger compartment 
blower unit does not operate: 
consult ALP 5 "Air flow fault"
Air flapsPR012:Mixing flap 
positionFrom 0 % (“Maximum 
cold” position: 15 ˚C)
to 100 % (“Maximum 
hot” position: 27 ˚C).In the event of a fault, see the 
interpretation of this 
parameter.
ET062:Recirculation 
flap positionOPEN if the flap is in the 
external air position.
CLOSED if the flap is in 
the recirculation 
position.In the event of a fault, refer to the 
interpretation of this status.
PR011:Distribution flap 
positionFrom 0 % (Air vent 
position)
to 100 % (De-icing 
position)In the event of a fault, see the 
interpretation of this 
parameter.
CLIM_V44_CCONF
                  
Vdiag No.: 44
MR-413-X44-62B000$460_eng.mif 
Page 33 of 99
62B-33
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION (CONTINUED)
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine stopped with ignition on (12 V APC), CLIMATE 
CONTROL  OFF (air conditioning compressor not engaged).
FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
TemperaturesPR001: Interior 
temperatureX = interior 
temperature ± 5 ˚C 
(invalid value: 87.5 ˚C)In the event of a fault, see the 
interpretation of this parameter.
PR002: External 
temperatureX = exterior 
temperature ± 5 ˚C 
(invalid value: 215 ˚C)In the event of a fault, see the 
interpretation of this parameter
Note: 
This parameter is displayed via the 
climate control computer but is 
generated by the UCH.
Motor activationAC001:Passenger 
compartment 
blowerWhen this command is 
run the passenger 
compartment blower 
comes on.In the event of a fault, refer to the 
interpretation of this command.
AC002:Recirculation 
motor: exterior airThis command is used to 
actuate the air 
recirculation motor to 
check that it is working.In the event of a fault, refer to the 
interpretation of this command.
AC003:Recirculation 
motor: 
recirculationThis command is used to 
actuate the air 
recirculation motor to 
check that it is working.In the event of a fault, refer to the 
interpretation of this command.
AC007:Distribution 
motor: de-icingThis command is used to 
activate the ventilation/
de-icing distribution flap 
to check that it is working.In the event of a fault, refer to the 
interpretation of this command.
AC006:Distribution 
motor: air ventThis command is used to 
activate the ventilation/
de-icing distribution flap 
to check that it is working.In the event of a fault, refer to the 
interpretation of this command.
AC004:Mixer motor: 
maximum coldThis command is used to 
activate the mixing flap to 
check that it is working.In the event of a fault, refer to the 
interpretation of this command.
AC005:Mixer motor: 
maximum hotIn the event of a fault, refer to the 
interpretation of this command. 
Page 34 of 99
62B-34
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
COLD LOOP SUB-FUNCTION
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine stopped with ignition on (12 V APC), CLIMATE 
CONTROL  OFF (air conditioning compressor not engaged).
FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
Request to engage 
the compressorET140:Air conditioning 
requestINACTIVEIn the event of a fault, refer to the 
interpretation of this status.
Passenger 
compartment 
blowerET141:Passenger 
compartment 
blowerRUNNING 
or 
STOPPED 
After a user requestIn the event of a fault, refer to the 
interpretation of this status.
CompressorET020:Compressor 
controlINACTIVEIn the event of a fault, refer to the 
interpretation of this status.
TemperaturesPR001:Interior 
temperatureX = interior 
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)In the event of a fault, see the 
interpretation of this 
parameter.
PR002:External 
temperatureX = exterior 
temperature ± 5 ˚C
(invalid value: 215 ˚C)In the event of a fault, see the 
interpretation of this 
parameter
Note: 
This parameter is displayed via 
the climate control computer but 
is generated by the UCH.
Air flapsPR012:Mixing flap 
positionFrom 0 % (“Maximum 
cold” position: 15 ˚C)
to 100 % (“Maximum 
hot” position: 27 ˚C).In the event of a fault, see the 
interpretation of this 
parameter. 
Page 35 of 99
62B-35
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
HEATING SUB-FUNCTION
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine stopped with ignition on (12 V APC), CLIMATE 
CONTROL  OFF (air conditioning compressor not engaged).
FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
Heated rear screenET086:Heated rear 
screen: manual 
modeINACTIVE In the event of a fault, refer to the 
interpretation of this status.
ET085:Heated rear 
screen: 
automatic modeINACTIVE In the event of a fault, refer to the 
interpretation of this status.
Passenger 
compartment 
ventilatorET141:Passenger 
compartment 
ventilatorRUNNING 
or 
STOPPED 
After a user requestIn the event of a fault, refer to the 
interpretation of this status.
Air mixing motorPR012:Mixing flap 
positionFrom 0 % (“Maximum 
cold” position: 15 ˚C)
to 100 % (“Maximum 
hot” position: 27 ˚C).In the event of a fault, see the 
interpretation of this 
parameter.
HeatingPR045:Current heating 
resistor power0 WIn the event of a fault, see the 
interpretation of this 
parameter.
TemperaturePR001:Interior 
temperatureX = interior 
temperature ± 5 ˚C 
(invalid value: 87.5 ˚C)In the event of a fault, see the 
interpretation of this 
parameter.
PR002:External 
temperatureX = exterior 
temperature ± 5 ˚C
(invalid value: 215 ˚C)In the event of a fault, consult the 
interpretation of this 
parameter.
Note: 
This parameter is displayed via 
the climate control computer but 
is generated by the UCH.
PR004:Coolant 
temperatureX = engine coolant 
temperature in ˚CIn the event of a fault, see the 
interpretation of this 
parameter. 
Page 36 of 99
62B-36
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
MAIN SCREEN
NOTESOnly carry out this conformity check after a full check using the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine stopped with ignition on (12 V APC), AIR 
CONDITIONING OFF (air conditioning compressor not activated).
Note:
This page lists the statuses and parameters provided by the climate control computer 
but which are not associated with the three sub-functions given in the conformity 
check (PASSENGER COMPARTMENT VENTILATION, COLD LOOP and HEATING 
sub-functions).
FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
Electrical suppliesPR092:Battery voltage10.5 V < X <14.4 VIn the event of a fault, see the 
interpretation of this 
parameter.
ET083:+ 12 V after 
ignition present ABSENT: Ignition off. 
PRESENT: Ignition on.In the event of a fault, refer to the 
interpretation of this status.
ET002:+ 12 V side 
lightsABSENT: Side lights off. 
PRESENT: Side lights 
on.In the event of a fault, refer to the 
interpretation of this status.
PR122:Night lighting 
level15 % = minimum 
lighting level
99 % = maximum 
lighting level
(side lights 
off: 102 %)In the event of a fault, refer to the 
interpretation of this status.
Note: 
This parameter is displayed via 
the climate control computer but 
is generated by the instrument 
panel. 
Page 37 of 99
62B-37
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning 
compressor activated).
Note:
–Read the parameters when the vehicle is cold (in the morning) to check the 
conformity of the temperature parameters (without thermometer). The two 
temperatures should be practically the same (as should the coolant temperature 
given by the injection system).
–The invalid values given in this check correspond to the value sent by the diagnostic 
tool (substitute value) when the sensor in question is faulty. A sensor fault can be 
detected when these invalid values are displayed (this is an important point for 
sensors on which fault finding cannot be performed, e.g. exterior temperature 
sensor).
FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
Passenger 
compartment 
blowerPR019: Passenger 
compartment 
fan PWM settingSpeed 0 = 0 %
Speed 8 = 100 %
Note:
The PWM signal is a 
modulated control 
voltage used to control 
the air conditioning 
blower power module.If there is a fault or for more 
information (to find the 
intermediate speed 
percentages), refer to the 
interpretation of this 
parameter.
Note:
If the parameter varies correctly, 
but the passenger compartment 
blower unit is not working: refer to 
fault finding chart no. 5.
ET141: Passenger 
compartment 
blowerRUNNING 
or 
STOPPED 
After a user request.In the event of a fault, refer to the 
interpretation of this status.
Air flapsPR012: Mixing flap 
positionFrom 0 % (“Maximum 
cold” position: 15 ˚C)
to 100 % (“Maximum 
hot” position: 27 ˚C).In the event of a fault, see the 
interpretation of this 
parameter.
ET062: Recirculation 
flap positionOPEN if the flap is in the 
external air position. 
CLOSED if the flap is in 
the recirculation 
position.In the event of a fault, refer to the 
interpretation of this status.
PR011: Distribution flap 
positionFrom 0 % (Air vent 
position)
to 100 % (De-icing 
position).In the event of a fault, refer to the 
interpretation of this status. 
Page 38 of 99
62B-38
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION (CONTINUED)
NOTESOnly carry out this conformity check after a full check using the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine running, (12 V APC) AIR CONDITIONING ON 
(air conditioning compressor activated).
FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
TemperaturesPR001:Interior 
temperatureX = interior 
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)In the event of a fault, see the 
interpretation of this 
parameter.
PR002:External 
temperatureX = exterior 
temperature ± 5 ˚C
(invalid value: 215 ˚C)In the event of a fault, see the 
interpretation of this 
parameter. 
Note: 
This parameter is displayed via 
the climate control computer but 
is generated by the UCH. 
Page 39 of 99
62B-39
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
COLD LOOP SUB-FUNCTION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning 
compressor activated).
FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
Request to activate 
the compressorET140:Air conditioning 
requestACTIVE In the event of a fault, refer to the 
interpretation of this status.
Passenger 
compartment 
blowerET141:Passenger 
compartment 
blowerRUNNINGIn the event of a fault, refer to the 
interpretation of this status.
CompressorET020:Compressor 
controlACTIVEIn the event of a fault, refer to the 
interpretation of this status.
TemperaturePR001:Interior 
temperatureX = interior 
temperature ± 5 ˚C 
(invalid value: 87.5 ˚C)In the event of a fault, see the 
interpretation of this 
parameter.
PR002:External 
temperatureX = exterior 
temperature ± 5 ˚C
 (invalid value: 215 ˚C)In the event of a fault, see the 
interpretation of this 
parameter
Note: 
This parameter is displayed via 
the climate control computer but 
is generated by the UCH.
Air flapsPR012:Mixing flap 
positionFrom 0 % (“Maximum 
cold” position: 15 ˚C)
to 100 % (“Maximum 
hot” position: 27 ˚C).In the event of a fault, see the 
interpretation of this 
parameter. 
Page 40 of 99
62B-40
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
HEATING SUB-FUNCTION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning 
compressor activated).
Order FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
1Heated rear 
screenET086: Heated rear 
screen: manual 
modeACTIVE: De-icing 
request using the control 
button.
INACTIVE otherwise.In the event of a fault, refer 
to the interpretation of this 
status.
ET085:Heated rear 
screen: 
automatic modeACTIVE: De-icing 
request using the control 
button. (“see clear” 
function)
INACTIVE otherwise.In the event of a fault, refer 
to the interpretation of this 
status.
2Passenger 
compartment 
blowerET141:Passenger 
compartment 
blowerRUNNINGIn the event of a fault, refer 
to the interpretation of this 
status.
3Air mixing 
motorPR012:Mixing flap 
positionFrom 0 % (“Maximum 
cold” position: 15 ˚C
to 100 % = “Maximum 
hot” position: 27 ˚C).In the event of a fault, see 
the interpretation of this 
parameter.
4HeatingPR045:Current heating 
resistor power0 < X < 900  WIn the event of a fault, see 
the interpretation of this 
parameter.
5TemperaturePR001:Interior 
temperatureX = interior 
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)In the event of a fault, see 
the interpretation of this 
parameter.
PR002: External 
temperatureX = exterior 
temperature ± 5 ˚C 
(invalid value: 215 ˚C)In the event of a fault, see 
the interpretation of this 
parameter
Note: 
This parameter is displayed 
via the climate control 
computer but is generated 
by the UCH.
PR004:Coolant 
temperatureX = engine coolant 
temperature in ˚C.In the event of a fault, see 
the interpretation of this 
parameter.