ABS Seat Ibiza 2020 Directive 2014/53/EU Bluetooth

Page 61 of 406



Page 56 of 90 Report No. : 60404487 001

IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict


TR F No. IEC62368_1 C

Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS)
N/A
Output
Circuit Condition U
oc (V) Time (s) I
sc (A) S (VA)
Meas. Limit Meas. Limit








Supplementary Information:
SC=Short circuit, OC=Open circuit


T.2, T.3,
T.4, T.5 TABLE: Steady force test
N/A
Part/Location Material Thickness
(mm) Probe Force
(N) Test
D uration
(s) Observation

Supplementary information:


T.6, T.9 TABLE: Impact test
P
Location/part Material Thickness
(mm) Height
(mm) Observation
Front, Top / Monitor PC /ABS Min. 1.5 1 300 No damaged, no hazard
Front / Keyboard PC/ABS Min. 1.5 1 300 No damaged, no hazard
Supplementary information:


T.7 TABLE: Drop test
N/A
Location/part Material Thickness
(mm) Height
(mm) Observation

Supplementary information:

Page 62 of 406



Page 57 of 90 Report No. : 60404487 001

IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict


TR F No. IEC62368_1 C

T.8 TABLE: Stress relief test
P
Location /Part Material Thickness
(mm ) Oven Temperature
(  C) Duration
(h) Observation
Monitor , Keyboard PC /ABS Min. 1.5 102.6 7 No shrinkage or
distortion.
No defeat its
safeguard function.
Supplementary information:


X TABLE: Alternative method for determining minimum clearances distance s
N/A
Clearance distanced
between: Peak of working voltage
(V) Required cl
(mm) Measured cl
(mm)

Supplementary information:


Page 165 of 406



Page 55 of 89 Report No. : 60404488 001

IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict


TR F No. IEC62368_1 C

Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS)
N/A
Output
Circuit Condition U
oc (V) Time (s) I
sc (A) S (VA)
Meas. Limit Meas. Limit








Supplementary Information:
SC=Short circuit, OC=Open circuit


T.2, T.3,
T.4, T.5 TABLE: Steady force test
N/A
Part/Location Material Thickness
(mm) Probe Force
(N) Test
Duration
(s) Observation

Supplementary informat ion:


T.6, T.9 TABLE: Impact test
P
Location/part Material Thickness
(mm) Height
(mm) Observation
Front, Top / Monitor PC /ABS Min. 1.5 1 300 No damaged, no hazard
Front / Keyboard PC/ABS Min. 1.5 1 300 No damaged, no hazard
Supplementary information:


T.7 TABLE: Drop test
N/A
Location/part Material Thickness
(mm) Height
(mm) Observation

Supplementary information:

Page 166 of 406



Page 56 of 89 Report No. : 60404488 001

IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict


TR F No. IEC62368_1 C

T.8 TABLE: Stress relief test
P
Location /Part Material Thickness
(mm) Oven Temperature
(  C) Duration
(h) Observation
Monit or , Keyboard PC /ABS Min. 1.5 102. 3 7 No shrinkage or
distortion.
No defeat its
safeguard function.
Supplementary information:


X TABLE: Alternative method for determining minimum clearances distances
N/A
Clearance distanced
between: Peak of working vol tage
(V) Required cl
(mm) Measured cl
(mm)

Supplementary information:


Page 267 of 406



Page 54 of 88 Report No. : 60404489 001

IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict


TR F No. IEC62368_1 C

Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS)
N/A
Output
Circuit Condition U
oc (V) Time (s) I
sc (A) S (VA)
Meas. Limit Meas. Limit








Supplementary Information:
SC=Short circuit, OC=Open circuit


T.2, T.3,
T.4, T.5 TABLE: Steady force test
N/A
Part/Location Material Thickness
(mm) Probe Force
(N) Test
Duration
(s) Observation

Supplementary information:


T.6, T. 9 TABLE: Impact test
P
Location/part Material Thickness
(mm) Height
(mm) Observation
Front, Top / Monitor PC /ABS Min. 1.5 1 300 No damaged, no hazard
Front / Keyboard PC/ABS Min. 1.5 1 300 No damaged, no hazard
Supplementary information:


T.7 TABLE: Drop test
N/A
Location/part Material Thickness
(mm) Height
(mm) Observation

Supplementary information:

Page 268 of 406



Page 55 of 88 Report No. : 60404489 001

IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict


TR F No. IEC62368_1 C

T.8 TABLE: Stress relief test
P
Location /Part Material Thickness
(mm) Oven Temperature
(  C) Duration
(h) Observation
Monitor , Keyboard PC /ABS Min. 1.5 86.0 7 No shrinkage or
distortion.
No defeat its
safeguard function.
Supplementary information:


X TABLE: Alternative method for determining minimum clearances distances
N/A
Clearance distanced
between: Peak of working voltage
(V) Require d cl
(mm) Measured cl
(mm)

Supplementary information:


Page 365 of 406



Page 54 of 88 Report No. : 60404490 001

IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict


TR F No. IEC62368_1 C

Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS)
N/A
Output
Circuit Condition U
oc (V) Time (s) I
sc (A) S (VA)
Meas. Limit Meas. Limit








Supplementary Information:
SC=Short circuit, OC=Open circuit


T.2, T.3,
T.4, T.5 TABLE: Steady force test
N/A
Part/Location Material Thickness
(mm) Probe Force
(N) Test
Duration
(s) Observation

Supplementary information:


T.6, T.9 TABLE: Impact test
P
Location/part Material Thickness
(mm) Height
(mm) Observation
Front, Top / Monitor PC /ABS Min. 1.5 1 300 No damaged, no hazard
Front / Keyboard PC/ABS Min. 1.5 1 300 No damaged, no hazard
Supplementary information:


T.7 TABL E: Drop test
N/A
Location/part Material Thickness
(mm) Height
(mm) Observation

Supplementary information:

Page 366 of 406



Page 55 of 88 Report No. : 60404490 001

IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict


TR F No. IEC62368_1 C

T.8 TABLE: Stress relief test
P
Location /Part Material Thickness
(mm) Oven Temperature
(  C) Duration
(h) Observation
Monitor , Keyboard PC /ABS Min. 1.5 86. 3 7 No shrinkage or
distortion.
No defeat its
safeguard function.
Supplementary information:


X TABLE: Alternative method for determining minimum clearances distances
N/A
Clearance distanced
between: Peak of working voltage
(V) Requi red cl
(mm) Measured cl
(mm)

Supplementary information: