charging SUZUKI GRAND VITARA 2001 2.G Service Workshop Manual

Page 3 of 801

YH4
GRAND
vol.1
0A
0B
1A
1B
3
3A
3B1
3C
3C1
3D
3E
3F
4A2
4B
5
6
7A5A
5B
5C
5E1
6A1
6A2
6A4
6B
6C
6E1
6E2
6F1
6F2
6G
6G1
6H
6K
7A1
7B1
7C1
7D
7E
7F
8
8B
8C
8D
8G
9
10
10A
8A
10B
6-1ENGINE
General Information and
Diagnosis (G16 / J20)
General Information and
Diagnosis (H25)
Engine Mechanical (G16)
Engine Mechanical (H25)
Engine Mechanical (J20)
Engine Cooling
Engine Fuel
Engine and Emission Control
System (SFI for G16 / J20)
Engine and Emission Control
System (SFI for H25)
Ignition System (G16)
Ignition System (J20 / H25)
Cranking System
(Reduction Type)
Cranking System
(No-Reduction Type)
Charging System
Exhaust System
TRANSMISSION, CLUTCH
AND DIFFERENTIAL
Manual Transmission (Type 1)
Manual Transmission (Type 2)
Automatic Transmission
Clutch (Hydraulic Type)
Transfer
Differential (Front)
Differential (Rear)
BODY ELECTRICAL SYSTEM
Wiring Diagram
Lighting System
Instrumentation / Driver
Information
Windows, Mirrors, Security
and Lock
Immobilizer Control System
BODY SERVICE
RESTRAINT SYSTEM
Seat Belt
Air Bag System GENERAL INFORMATION
General Information
Maintenance and Lubrication
TABLE OF CONTENTS TABLE OF CONTENTS SECTIONSECTION
0B
HEATING AND AIR
CONDITIONING
Heater and Ventilation
Air Conditioning
STEERING, SUSPENSION,
WHEELS AND TIRES
Front End Alignment
Power Steering (P / S) System
Steering Wheel and Column
(Not Equipped with Air Bag)
Air Bag Steering Wheel
and Column
Front Suspension
Rear Suspension
Wheel and Tires
1A
3A 0A
1B
3B1
3C
3C1
3D
3E
3F36A16
6A2
6A4
6B
6C
6E1
6E2
6F1
DRIVE SHAFT / PROP. SHAFT
Front Drive Shaft / Shaft
Bearing, Oil Seal
Propeller Shaft
BRAKES
Brake Pipe / Hose / Master
Cylinder
Front Brakes
Parking and Rear Brakes
Antilock Brake System
4A2
4B
5
5A
5B
5C
5E1
6F2
6G
6G1
6H
6K
7A
7A1
7B1
7C1
7D
7E
7F
8
8A
8B
8C
8D
8G
9
10
10A
10B
6-1
NOTE:
The screen toned Sections 6 ± 6K are included in Volume 2 and Section 8A is in Wiring
Diagram Manual.

Page 70 of 801

YH4
GRAND
VITARA
1A-18 HEATER AND VENTILATION
11) Remove heater core pipe clamps (1) and grommet (2).
12) Pull out heater core (1) from unit (2).
INSTALLATION
1) Install heater unit by reversing removal procedure, noting the
following items.
When installing each part, be careful not to catch any cable or
wiring harness.
When installing steering column assembly, refer to STEER-
ING COLUMN INSTALLATION in Section 3C or 3C1.
2) Install control cables. (Refer to HEATER CONTROL CABLES in
this section.)
3) Fill engine coolant to radiator.
4) Enable air bag system, if equipped. Refer to ENABLING AIR
BAG SYSTEM in Section 10B.
5) Evacuate and charge system. Refer to items EVACUATING
SYSTEM and PROCEDURE OF CHARGING in Section 1B.

Page 72 of 801

YH4
GRAND
VITARA
1B
AIR CONDITIONING (OPTIONAL) 1B-1
GENERAL DESCRIPTION1B- 3 . . . . . . . . . . . . . .
Identification of Refrigerating System 1B- 3. . . .
Refrigerant Flow of Air Conditioning
System 1B- 4. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Major Components and Location 1B- 5. . . . . . .
DIAGNOSIS1B- 6 . . . . . . . . . . . . . . . . . . . . . . . . . . .
General 1B- 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnosis of Abnormal Noise 1B- 8. . . . . . . . . .
Quickly Checking of Refrigerant Charge
(If Equipped with Sight Glass) 1B-10. . . . . . . . .
Compression System Diagnosis 1B-11. . . . . . . .
Performance Diagnosis 1B-12. . . . . . . . . . . . . . .
Wiring Circuit 1B-16. . . . . . . . . . . . . . . . . . . . . . . .
Inspection of A / C Controller and Its
Circuits 1B-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT RECOVERY,
EVACUATION AND CHARGING1B-23 . . . . . . . .
Operation Procedure for Charging A / C
with Refrigerant 1B-23. . . . . . . . . . . . . . . . . . . . .
Recovery 1B-24. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Evacuating 1B-25. . . . . . . . . . . . . . . . . . . . . . . . . .
Charging 1B-26. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing Manifold Gauge Set 1B-29. . . . . . . . .
Leak-Testing Refrigerant System 1B-29. . . . . . .
Liquid Leak Detectors 1B-29. . . . . . . . . . . . . . . . .
ON-VEHICLE SERVICE1B-30 . . . . . . . . . . . . . . . .
Precaution 1B-30. . . . . . . . . . . . . . . . . . . . . . . . . . .
A / C Condenser Assembly 1B-33. . . . . . . . . . . . .
Condenser Cooling Fan Assembly 1B-35. . . . . .
SECTION 1B
AIR CONDITIONING (OPTIONAL)
WARNING:
For vehicles equipped with Supplemental Restraint (Air Bag) System:
Service on and around the air bag system components or wiring must be performed only by an autho-
rized SUZUKI dealer. Refer to ªAir Bag System Components and Wiring Location Viewº under ªGener-
al Descriptionº in air bag system section in order to confirm whether you are performing service on
or near the air bag system components or wiring. Please observe all WARNINGS and ªService Precau-
tionsº under ªOn-Vehicle Serviceº in air bag system section before performing service on or around
the air bag system components or wiring. Failure to follow WARNINGS could result in unintentional
activation of the system or could render the system inoperative. Either of these two conditions may
result in severe injury.
Technical service work must be started at least 90 seconds after the ignition switch is turned to the
ªLOCKº position and the negative cable is disconnected from the battery. Otherwise, the system may
be activated by reserve energy in the Sensing and Diagnostic Module (SDM).
CAUTION:
The air conditioning system of this vehicle uses refrigerant HFC-134a (R-134a).
None of refrigerant, compressor oil and component parts is interchangeable between two types of A / C:
one using refrigerant CFC-12 (R-12) and the other using refrigerant HFC-134a (R-134a).
Be sure to check which refrigerant is used before any service work including inspection and mainte-
nance. For identification between these two types, refer to the description in page 1B-2.
When replenishing or changing refrigerant and compressor oil and when replacing parts, make sure
that the material or the part to be used is appropriate to the A / C installed in the vehicle being serviced.
Use of incorrect one will result in leakage of refrigerant, damage in parts or other faulty condition.
For basic servicing method of the air conditioning system that is not described in this section, refer to AIR CONDI-
TIONING BASIC MANUAL (99520-02130).
CONTENTS

Page 77 of 801

YH4
GRAND
VITARA
1B-6 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS
GENERAL
ConditionPossible CauseCorrection
Cool air won't come out
(A / C system won't
operative)No refrigerant
Fuse blown
A / C switch faulty
Blower motor switch faulty
A / C thermistor faulty
Dual pressure switch faulty
Wiring or grounding faulty
A / C ON permission signal in ECM
faulty
A / C controller and its circuit faultyRecover, evacuation and charging.
Check ªIG METERº fuse, ªREAR DEFGº
fuse, and ªA / C FUSEº and check for
short circuit to ground.
Check A / C switch.
Check blower motor switch.
Check A / C evaporator thermistor.
Check dual pressure switch.
Repair as necessary.
Check ON permission signal.
Check A / C controller and its circuit.
Cool air won't come out
(A / C compressor won't
operative)Magnet clutch faulty
Compressor relay faulty
Compressor thermal switch faulty
(if equipped)
Drive belt loose or broken
Compressor faulty
A / C ON permission signal in ECM
faulty
A / C controller faultyCheck magnet clutch.
Check compressor thermal switch.
Check compressor relay.
Adjust or replace drive belt.
Check compressor.
Check ON permission signal.
Check A / C controller.
Cool air won't come out
(A / C condenser cooling
fan motor won't
operative)Condenser cooling fan relay faulty
Wiring or grounding faulty
ªA / C condenser cooling fan relayº
signal in ECM faulty
Condenser cooling fan motor faultyCheck condenser cooling fan relay.
Repair as necessary.
Check A / C condenser cooling fan relay
signal.
Check condenser cooling fan motor.
Cool air won't come out
(Blower motor won't
operative)Fuse blown
Blower motor relay faulty
Blower motor resistor faulty
Blower motor switch faulty
Wiring or grounding faulty
Blower motor faultyCheck ªHEATER FUSEº, ªREAR DEFGº
fuse and check for short circuit to
ground.
Check blower motor relay.
Check blower motor resistor.
Check blower motor switch.
Repair as necessary.
Check blower motor.
Cool air won't come out
or insufficient cooling
(A / C system normal
operative)Insufficient or excessive charge of
refrigerant
Refrigerant leak in system
Condenser clogged
A / C evaporator clogged or frosted
A / C thermistor faulty
A / C controller faulty
Expansion valve faulty
Drive belt slipping
Magnetic clutch faultyCheck charge of refrigerant.
Check system for leaks.
Check condenser.
Check A / C evaporator.
Check A / C thermistor.
Check A / C controller.
Check expansion valve.
Check or replace drive belt.
Check magnetic clutch.

Page 78 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-7
ConditionPossible CauseCorrection
Cool air does not come
out or insufficient
cooling (A / C system
normal operative)Compressor faulty
Air in A / C system
Air leaking from cooling unit or air
duct
Heater and ventilation system faulty
Blower motor faulty
Excessive compressor oil existing in
A / C systemCheck compressor.
Replace condenser dryer, and
evacuation and charging.
Repair as necessary.
Check blower unit.
Check heater control lever assembly.
Check heater assembly.
Check blower motor.
Pull out compressor oil in A / C system
circuit, and replace compressor.
Cool air does not comes
out only intermittentlyWiring connection faulty
Expansion valve faulty
Excessive moisture in A / C system
A / C controller faulty
Magnetic clutch faulty
Excessive charge of refrigerantRepair as necessary.
Check expansion valve.
Replace condenser dryer, and
evacuation and charging.
Check A / C controller.
Check magnetic clutch.
Check charge of refrigerant.
Cool air comes out only
at high speedsCondenser clogged
Insufficient charge of refrigerant
Air in A / C system
Drive belt slipping
Compressor faultyCheck condenser.
Check charge of refrigerant.
Replace condenser dryer, and
evacuation and charging.
Adjust or replace drive belt.
Check compressor.
Cool air does not comes
out only at high speedsExcessive charge of refrigerant
A / C evaporator frostedCheck charge refrigerant.
Check A / C evaporator.
Check A / C thermistor.
Insufficient velocity of
cooled airA / C evaporator clogged or frosted
Air leaking from cooling unit or air
duct
Blower motor faulty
Wiring or grounding faultyCheck A / C evaporator.
Repair as necessary.
Check blower motor.
Repair as necessary.

Page 83 of 801

YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-12 AIR CONDITIONING (OPTIONAL)
PERFORMANCE DIAGNOSIS
1) Confirm that vehicle and environmental conditions are as fol-
lows.
Vehicle is not exposed to direct sun.
Ambient temperature is within 15C ± 35C (59F ± 95F).
2) Make sure that high pressure valve (1) and low pressure valve
(2) of manifold gauge are firmly closed.
3) Connect high pressure charging hose (3) to high pressure ser-
vice valve (5) on vehicle, and connect low pressure charging
hose (4) to low pressure service valve (6) on vehicle.
4) Bleed the air in charging hoses (3), (4) by loosening their respec-
tive nuts on manifold gauge, utilizing the refrigerant pressure.
When a hiss is heard, immediately tighten nut.
CAUTION:
Do not interchange high and low pressure charging
hoses by mistake.
5) Warm up engine to normal operating temperature (engine cool-
ant temperature at 80 ± 90C (176 ± 194F)) and keep it at spe-
cified idle speed. (Radiator cooling fan should not be working
when checking pressure and temperature.)
6) Turn A / C switch ON, and set blower switch at ªHIº (4th position),
temperature control knob at ªCOOLº, air outlet control knob at
ªFACEº, fresh / circulation control knob at ªCIRCULATIONº.
(Confirm that A / C compressor and condenser fan are working.)
7) Keep all windows, doors and engine food open.
Ambient temperature
15 ± 35C (59F ± 95F)
Engine rpmKeep to 1,500 rpm.
Blower motor switchMax. (4th position)
Temperature controlMax. cool
Air outlet controlFace
Vehicle doorsAll open
Air inlet door positionRecirculation
8) With about 20 mm (0.8 in.) of dry bulb thermometer (1) inserted
into center duct air outlet and another one set near evaporator
air inlet, read temperature indicated on each thermometer.

Page 94 of 801

YH4
GRAND
VITARA
Charge 440  50 g, 14.2  1.9 oz of
refrigerant in gas form
AIR CONDITIONING (OPTIONAL) 1B-23
REFRIGERANT RECOVERY, EVACUATION AND CHARGING
WARNING:
Your eyes should not be exposed to refrigerant (liquid).
Any liquid Refrigerant-134a escaping by accident shows a temperature as low as approx. ± 6C
(42.8F) below freezing point. Should liquid HFC-134a (R-134a) get into your eyes, it may cause a seri-
ous injury. To protect your eyes against such accident, it is necessary to always wear goggles. Should
it occur that HFC-134a (R-134a) strikes your eye(s), consult a doctor immediately.
± DO NOT USE YOUR HAND TO RUB THE AFFECTED EYE(S). INSTEAD, use quantities of fresh cold
water to splash it over the affected area to gradually raise temperature of such area above freezing
point.
± Obtain proper treatment as soon as possible from a doctor or eye specialist.
Should the HFC-134a (R-134a) liquid come into contact with your skin, the affected area should be
treated in the same manner as when skin is frostbitten or frozen.
Refrigerant must not be handled near where welding or steam cleaning is performed.
Refrigerant should be kept at a cold and dark place. It should never be stored where a high tempera-
ture is anticipated, e.g. where exposed to direct sun light, close to fire or inside vehicle (including
trunk room).
Avoid breathing fumes produced when HFC-134a (R-134a) is burned. Such fumes may be hazardous
to health.
OPERATION PROCEDURE FOR CHARGING A / C WITH REFRIGERANT

Page 95 of 801

YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-24 AIR CONDITIONING (OPTIONAL)
RECOVERY
NOTE:
When discharging refrigerant out of A / C system, always re-
cover it by using refrigerant recovery and recycling equip-
ment (1). Discharging it into atmosphere would cause ad-
verse effect to environments.
When handling recovery and recycling equipment, be sure
to follow the instruction manual for the equipment.

Page 96 of 801

YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
AIR CONDITIONING (OPTIONAL) 1B-25
EVACUATING
EVACUATING PROCEDURE
CAUTION:
Do not evacuate before recovering refrigerant in system.
NOTE:
Whenever opened (exposed to atmospheric air), air condition-
ing system must be evacuated by using a vacuum pump. The
A / C system should be attached with a manifold gauge set, and
should be evacuated for approx. 15 minutes.
1) Connect high charging hose (1) and low charging hose (2) of
manifold gauge set (3) respectively as follows:
High Charging Hose (1)
High pressure charging valve (4)
on Discharge Hose
Low Charging Hose (2)i
Low pressure charging valve (5)
on Suction Pipe
2) Attach center charging hose (6) of manifold gauge set (3) to vac-
uum pump (7).
3) Operate vacuum pump (7), and then open discharge-side valve
(9) (Hi) of manifold gauge set (3).
If there is no blockage in the system, there will be an indication
on high pressure gauge (10).
When this occurs, open the other-side valve (8) (Lo) of the set.
4) Approx. 10 minutes later, low pressure gauge (11) should show
a vacuum lower than ± 760 mmHg providing no leakage exists.
NOTE:
If the system does not show a vacuum below ± 760 mmHg,
close both valves, stop vacuum pump and watch move-
ment of low pressure gauge.
Increase in the gauge reading suggests existence of leak-
age. In this case, repair the system before continuing its
evacuation.
If the gauge shows a stable reading (suggesting no leak-
age), continue evacuation.
5) Evacuation should be carried out for a total of at least 15 minutes.
6) Continue evacuation until low pressure gauge indicates a vacu-
um less than ± 760 mmHg, and then close both valves (8), (9).
7) Stop vacuum pump (7). Disconnect center charging hose (6) from
pump inlet. Now, the system is ready for charging refrigerant.
CHECKING SYSTEM FOR PRESSURE LEAKS
After completing the evacuation, close manifold gauge high pres-
sure valve (HI) and low-pressure valve (LO) and wait 10 minutes.
Verify that low-pressure gauge reading has not changed.
CAUTION:
If the gauge reading moves closer to ª0º, there is a leak
somewhere. Inspect the tubing connections, make neces-
sary corrections, and evacuate system once again, making
sure that there are no leaks.

Page 97 of 801

YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-26 AIR CONDITIONING (OPTIONAL)
CHARGING
CAUTION:
ALWAYS CHARGE THROUGH LOW PRESSURE-SIDE of A / C system at after the initial charging is per-
formed from the high-pressure side with the engine stopped.
NEVER CHARGE TO HIGH PRESSURE-SIDE of A / C system with engine running.
Do not charge while compressor is hot.
When installing tap valve to refrigerant container to make a hole there through, carefully follow direc-
tions given by manufacturer.
A pressure gauge should always be used before and during charging.
The refrigerant container should be emptied of refrigerant when discarding it.
The refrigerant container should not be heated up to 40C (104F) or over.
Refrigerant container should not be reversed in direction during charging. Reversing in direction
causes liquid refrigerant to enter compressor, causing troubles, such as compression of liquid refrig-
erant and the like.
NOTE:
The air conditioning system contains HFC-134a (R-134a).
Described here is a method to charge the air conditioning system with refrigerant from the refrigerant ser-
vice container.
When charging refrigerant recovered by using the refrigerant and recycling equipment (when recycling
refrigerant), follow the procedure described in the equipment manufacturer's instruction manual.
The initial charging of the A / C system is performed from the high-
pressure side with the engine stopped.
And next, this method must be followed by charging from the low-
pressure side with the engine running.
1) Check to make sure that hoses are routed properly after eva-
cuating the system.
2) Connect Low-side hose (1) and High side hose (2) of the man-
ifold gauge set (3) in position. Thus open refrigerant container
valve (4) to purge the charging line.
3) Open the high-pressure side valve (6) and charge refrigerant to
system.
4) After a while, open the low-pressure side valve (5) and close the
high-pressure side valve (6).
WARNING:
Make sure that high pressure-side valve is closed se-
curely.
5) Start engine and keep engine speed at 1500 r / min. Then, oper-
ate air conditioning.
6) Charge A / C system with refrigerant in vapor state. At this time,
refrigerant container should be held upright.

Page:   1-10 11-20 21-30 next >