Assembly SUZUKI GRAND VITARA 2002 2.G Service User Guide
Page 68 of 801
YH4
GRAND
VITARA
1A-16 HEATER AND VENTILATION
1. Heater unit
2. Heater core
3. Damper
4. Heater mode control actuator
5. Heater mode control switch
6. Heater control lever assembly
HEATER UNIT
Page 69 of 801
YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-17
1. Dash panel (engine room) 2. Nuts
REMOVAL
WARNING:
Failure to follow the following procedure and WARNING
may cause air bag deployment, personal injury, damage to
parts, or air bag being unable to deploy.
Never rest a steering column assembly on steering wheel
with air bag (inflator) module face down and column verti-
cal.
When handling the air bag (inflator) modules (driver and
passenger), be careful not to drop it or apply an impact to
it. If an excessive impact was applied (e.g., dropped from
a height of 91.4 cm (3 feet) or more, never attempt disas-
sembly or repair but replace it with a new one.
When grease, cleaning agent. Oil, water, etc. has got onto
air bag (inflator) modules (driver and passenger), wipe off
immediately with a dry cloth.
1) Disconnect negative (±) cable at battery.
2) Disable air bag system, if equipped. Refer to DISABLING AIR
BAG SYSTEM in Section 10B.
3) Drain engine coolant and disconnect heater hose (1) from
heater unit.
4) Remove instrument panel, refer to item INSTRUMENT PANEL
REMOVAL in Section 9.
5) Remove cooling unit (If equipped).
Refer to item EVAPORATOR (COOLING UNIT) REMOVAL in
Section 1B.
6) Disconnect rear duct (4) from heater unit.
7) Disconnect heater mode control actuator lead wire (1) at cou-
plers.
8) Remove A / C controller (2) (If equipped).
9) Remove SDM (3) (If equipped).
10) Remove heater unit.
Page 70 of 801
YH4
GRAND
VITARA
1A-18 HEATER AND VENTILATION
11) Remove heater core pipe clamps (1) and grommet (2).
12) Pull out heater core (1) from unit (2).
INSTALLATION
1) Install heater unit by reversing removal procedure, noting the
following items.
When installing each part, be careful not to catch any cable or
wiring harness.
When installing steering column assembly, refer to STEER-
ING COLUMN INSTALLATION in Section 3C or 3C1.
2) Install control cables. (Refer to HEATER CONTROL CABLES in
this section.)
3) Fill engine coolant to radiator.
4) Enable air bag system, if equipped. Refer to ENABLING AIR
BAG SYSTEM in Section 10B.
5) Evacuate and charge system. Refer to items EVACUATING
SYSTEM and PROCEDURE OF CHARGING in Section 1B.
Page 72 of 801
YH4
GRAND
VITARA
1B
AIR CONDITIONING (OPTIONAL) 1B-1
GENERAL DESCRIPTION1B- 3 . . . . . . . . . . . . . .
Identification of Refrigerating System 1B- 3. . . .
Refrigerant Flow of Air Conditioning
System 1B- 4. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Major Components and Location 1B- 5. . . . . . .
DIAGNOSIS1B- 6 . . . . . . . . . . . . . . . . . . . . . . . . . . .
General 1B- 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnosis of Abnormal Noise 1B- 8. . . . . . . . . .
Quickly Checking of Refrigerant Charge
(If Equipped with Sight Glass) 1B-10. . . . . . . . .
Compression System Diagnosis 1B-11. . . . . . . .
Performance Diagnosis 1B-12. . . . . . . . . . . . . . .
Wiring Circuit 1B-16. . . . . . . . . . . . . . . . . . . . . . . .
Inspection of A / C Controller and Its
Circuits 1B-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT RECOVERY,
EVACUATION AND CHARGING1B-23 . . . . . . . .
Operation Procedure for Charging A / C
with Refrigerant 1B-23. . . . . . . . . . . . . . . . . . . . .
Recovery 1B-24. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Evacuating 1B-25. . . . . . . . . . . . . . . . . . . . . . . . . .
Charging 1B-26. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing Manifold Gauge Set 1B-29. . . . . . . . .
Leak-Testing Refrigerant System 1B-29. . . . . . .
Liquid Leak Detectors 1B-29. . . . . . . . . . . . . . . . .
ON-VEHICLE SERVICE1B-30 . . . . . . . . . . . . . . . .
Precaution 1B-30. . . . . . . . . . . . . . . . . . . . . . . . . . .
A / C Condenser Assembly 1B-33. . . . . . . . . . . . .
Condenser Cooling Fan Assembly 1B-35. . . . . .
SECTION 1B
AIR CONDITIONING (OPTIONAL)
WARNING:
For vehicles equipped with Supplemental Restraint (Air Bag) System:
Service on and around the air bag system components or wiring must be performed only by an autho-
rized SUZUKI dealer. Refer to ªAir Bag System Components and Wiring Location Viewº under ªGener-
al Descriptionº in air bag system section in order to confirm whether you are performing service on
or near the air bag system components or wiring. Please observe all WARNINGS and ªService Precau-
tionsº under ªOn-Vehicle Serviceº in air bag system section before performing service on or around
the air bag system components or wiring. Failure to follow WARNINGS could result in unintentional
activation of the system or could render the system inoperative. Either of these two conditions may
result in severe injury.
Technical service work must be started at least 90 seconds after the ignition switch is turned to the
ªLOCKº position and the negative cable is disconnected from the battery. Otherwise, the system may
be activated by reserve energy in the Sensing and Diagnostic Module (SDM).
CAUTION:
The air conditioning system of this vehicle uses refrigerant HFC-134a (R-134a).
None of refrigerant, compressor oil and component parts is interchangeable between two types of A / C:
one using refrigerant CFC-12 (R-12) and the other using refrigerant HFC-134a (R-134a).
Be sure to check which refrigerant is used before any service work including inspection and mainte-
nance. For identification between these two types, refer to the description in page 1B-2.
When replenishing or changing refrigerant and compressor oil and when replacing parts, make sure
that the material or the part to be used is appropriate to the A / C installed in the vehicle being serviced.
Use of incorrect one will result in leakage of refrigerant, damage in parts or other faulty condition.
For basic servicing method of the air conditioning system that is not described in this section, refer to AIR CONDI-
TIONING BASIC MANUAL (99520-02130).
CONTENTS
Page 73 of 801
YH4
GRAND
VITARA
1B-2 AIR CONDITIONING (OPTIONAL)
Condenser Dryer (Receiver / Dryer) 1B-36. . . . . .
Air Filter Element 1B-37. . . . . . . . . . . . . . . . . . . . .
Cooling Unit (Evaporator) 1B-39. . . . . . . . . . . . . .
Expansion Valve 1B-42. . . . . . . . . . . . . . . . . . . . .
A / C Evaporator Thermistor (Evaporator
Temperature Sensor) 1B-43. . . . . . . . . . . . . . . .
Refrigerant Pipes and Hoses 1B-44. . . . . . . . . . .
A / C Switch 1B-45. . . . . . . . . . . . . . . . . . . . . . . . . .
A / C Controller 1B-46. . . . . . . . . . . . . . . . . . . . . . . .
Dual Pressure Switch 1B-47. . . . . . . . . . . . . . . . . A / C Compressor Relay and A / C
Condenser Cooling Fan Relay 1B-48. . . . . . . .
Compressor Assembly 1B-49. . . . . . . . . . . . . . . .
Magnet Clutch Assembly
(For Denso Compressor) 1B-53. . . . . . . . . . .
Magnet Clutch Assembly
(For Seiko Seiki Compressor) 1B-56. . . . . . .
Lip Type Seal (For Seiko Seiki) 1B-59. . . . . . .
REQUIRED SERVICE MATERIAL1B-61 . . . . . . . .
SPECIAL TOOLS1B-61 . . . . . . . . . . . . . . . . . . . . . .
Page 75 of 801
YH4
GRAND
VITARA
1. Compressor
2. Magnet clutch
3. Condenser assembly
4. Receiver / dryer
5. Dual pressure switch
6. Expansion valve
7. Evaporator: Liquid
: Vapor
: Superheated vapor
1B-4 AIR CONDITIONING (OPTIONAL)
REFRIGERANT FLOW OF AIR CONDITIONING SYSTEM
Page 76 of 801
YH4
GRAND
VITARA
1. Cooling unit
2. Compressor
3. Condenser assembly
4. Receiver / dryer
5. Discharge hose
6. Suction hose
7. Condenser outlet pipe
8. Liquid pipe9. Expansion valve
10. Ventilation air
11. Foot air
12. Defroster air
13. Demister air
14. Fresh air
15. Recirculation air
16. Heater unit17. Air inlet box
18. Dual pressure switch
19. Low pressure charge valve
20. High pressure charge valve
21. Suction pipe
22. Sight glass
CAMI PRODUCTION VEHICLE IWATA PRODUCTION VEHICLE
AIR CONDITIONING (OPTIONAL) 1B-5
MAJOR COMPONENTS AND LOCATION
Page 78 of 801
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-7
ConditionPossible CauseCorrection
Cool air does not come
out or insufficient
cooling (A / C system
normal operative)Compressor faulty
Air in A / C system
Air leaking from cooling unit or air
duct
Heater and ventilation system faulty
Blower motor faulty
Excessive compressor oil existing in
A / C systemCheck compressor.
Replace condenser dryer, and
evacuation and charging.
Repair as necessary.
Check blower unit.
Check heater control lever assembly.
Check heater assembly.
Check blower motor.
Pull out compressor oil in A / C system
circuit, and replace compressor.
Cool air does not comes
out only intermittentlyWiring connection faulty
Expansion valve faulty
Excessive moisture in A / C system
A / C controller faulty
Magnetic clutch faulty
Excessive charge of refrigerantRepair as necessary.
Check expansion valve.
Replace condenser dryer, and
evacuation and charging.
Check A / C controller.
Check magnetic clutch.
Check charge of refrigerant.
Cool air comes out only
at high speedsCondenser clogged
Insufficient charge of refrigerant
Air in A / C system
Drive belt slipping
Compressor faultyCheck condenser.
Check charge of refrigerant.
Replace condenser dryer, and
evacuation and charging.
Adjust or replace drive belt.
Check compressor.
Cool air does not comes
out only at high speedsExcessive charge of refrigerant
A / C evaporator frostedCheck charge refrigerant.
Check A / C evaporator.
Check A / C thermistor.
Insufficient velocity of
cooled airA / C evaporator clogged or frosted
Air leaking from cooling unit or air
duct
Blower motor faulty
Wiring or grounding faultyCheck A / C evaporator.
Repair as necessary.
Check blower motor.
Repair as necessary.
Page 104 of 801
YH4
GRAND
VITARA
2. Bolt
For CAMI production vehicle
For IWATA production vehicle
AIR CONDITIONING (OPTIONAL) 1B-33
A / C CONDENSER ASSEMBLY
INSPECTION
Check
a) condenser fins for blockage
b) condenser fittings for leakage
c) condenser fins for damage
Clogged condenser fins should be washed with water, and should
be dried with compressed air.
CAUTION:
Be careful not to damage condenser fins. If condenser fin is
bent, straighten it by using a screwdriver or pair of pliers. If
any leakage is found from fitting or tube, repair or replace
condenser.
REMOVAL
1) Disconnect negative (±) cable at battery.
2) Recover refrigerant by using recovery and recycling equipment.
Be sure to follow the instruction manual for the equipment.
The amount of compressor oil removed must be measured and
the same amount added to the system.
3) Remove front bumper assembly and remove lower stay (1) if
equipped (Refer to Section 9 ªBODY SERVICEº).
4) Disconnect compressor discharge hose (1) from condenser in-
let fittings.
CAUTION:
As soon as above hose and pipe are disconnected, cap
opened fittings so that moisture and dust do not enter
condenser.
Page 105 of 801
YH4
GRAND
VITARA
3
1B-34 AIR CONDITIONING (OPTIONAL)
5) Disconnect coupler from dual pressure switch (1).
6) Disconnect condenser outlet pipe (3).
7) Disconnect condenser cooling fan motor coupler (2).
8) Remove condenser with fan.
NOTE:
Be careful not to damage fins of condenser and radiator.
9) Remove A / C condenser cooling fan assembly from condenser.
INSTALLATION
Reverse removal sequence to install condenser, noting following
point.
1) When replacing condenser, add 20 to 30 cc of refrigerating oil
from compressor suction-side.
2) Evacuate and charge system according to previously-described
procedure.