actuator SUZUKI GRAND VITARA 2002 2.G Service Owner's Guide
Page 580 of 801
YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-25
POWER DOOR LOCK ACTUATOR CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller.
3) Use a 12 V battery to connect its (+) terminal to terminal E02-1,
and its (±) terminal to terminal E02-2 and E02-3. Check all power
doors are locked.
If check result is satisfactory, this circuit is OK.
POWER SUPPLY AND GROUNDING CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-7 and
groundAnytime10 ± 14 V
E02-14 and
groundAnytimeContinuity
If check result is satisfactory, this circuit is OK.
DOOR LOCK KEY AND POWER DOOR LOCK SWITCH
CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller.
3) Check for continuity between following terminals at each condi-
tion.
Terminals
ConditionSpecification
E02-8 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is LOCK positionContinuity
E02-9 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is UNLOCK positionContinuity
If check result is satisfactory, this circuit is OK.
Page 582 of 801
YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-27
POWER DOOR LOCK SWITCH
INSPECTION
Refer to POWER DOOR LOCK SWITCH INSPECTION of POWER
DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT EQUIPPED)
in this section.
KEY CYLINDER SWITCH (DRIVER SIDE)
INSPECTION
Refer to KEY CYLINDER SWITCH (DRIVER SIDE) INSPECTION
of POWER DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT
EQUIPPED) in this section.
POWER DOOR LOCK ACTUATOR
INSPECTION
Refer to POWER DOOR LOCK ACTUATOR INSPECTION of
POWER DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT
EQUIPPED) in this section.
Page 585 of 801
YH4
GRAND
VITARA
Terminal
Operation
If mirror heater is not equipped
If mirror heater is equipped
8D-30 WINDOWS, MIRRORS, SECURITY AND LOCKS
POWER DOOR MIRROR CONTROL SYSTEM
INSPECTION
MIRROR SWITCH
1) Remove mirror switch from instrument panel.
2) Check for continuity between terminals at each switch position
as shown below.
If check result is not as specified, replace mirror switch.
DOOR MIRROR ACTUATOR
1) Remove garnish from door.
2) Disconnect door mirror coupler.
3) Check that door mirror operates properly when battery voltage
is applied to connector terminals.
Connect battery positive and negative terminal to the door mirror
terminal shown below and check operation.
If it does not operate as specified in table below, replace door
mirror assembly.
VBlYVBlY
Up
Down
Left
Right
NOTE:
When installing door mirror to door, be careful not to pinch
harness between door and door mirror.