change SUZUKI GRAND VITARA 2004 2.G Service User Guide
Page 72 of 801
YH4
GRAND
VITARA
1B
AIR CONDITIONING (OPTIONAL) 1B-1
GENERAL DESCRIPTION1B- 3 . . . . . . . . . . . . . .
Identification of Refrigerating System 1B- 3. . . .
Refrigerant Flow of Air Conditioning
System 1B- 4. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Major Components and Location 1B- 5. . . . . . .
DIAGNOSIS1B- 6 . . . . . . . . . . . . . . . . . . . . . . . . . . .
General 1B- 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnosis of Abnormal Noise 1B- 8. . . . . . . . . .
Quickly Checking of Refrigerant Charge
(If Equipped with Sight Glass) 1B-10. . . . . . . . .
Compression System Diagnosis 1B-11. . . . . . . .
Performance Diagnosis 1B-12. . . . . . . . . . . . . . .
Wiring Circuit 1B-16. . . . . . . . . . . . . . . . . . . . . . . .
Inspection of A / C Controller and Its
Circuits 1B-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT RECOVERY,
EVACUATION AND CHARGING1B-23 . . . . . . . .
Operation Procedure for Charging A / C
with Refrigerant 1B-23. . . . . . . . . . . . . . . . . . . . .
Recovery 1B-24. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Evacuating 1B-25. . . . . . . . . . . . . . . . . . . . . . . . . .
Charging 1B-26. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing Manifold Gauge Set 1B-29. . . . . . . . .
Leak-Testing Refrigerant System 1B-29. . . . . . .
Liquid Leak Detectors 1B-29. . . . . . . . . . . . . . . . .
ON-VEHICLE SERVICE1B-30 . . . . . . . . . . . . . . . .
Precaution 1B-30. . . . . . . . . . . . . . . . . . . . . . . . . . .
A / C Condenser Assembly 1B-33. . . . . . . . . . . . .
Condenser Cooling Fan Assembly 1B-35. . . . . .
SECTION 1B
AIR CONDITIONING (OPTIONAL)
WARNING:
For vehicles equipped with Supplemental Restraint (Air Bag) System:
Service on and around the air bag system components or wiring must be performed only by an autho-
rized SUZUKI dealer. Refer to ªAir Bag System Components and Wiring Location Viewº under ªGener-
al Descriptionº in air bag system section in order to confirm whether you are performing service on
or near the air bag system components or wiring. Please observe all WARNINGS and ªService Precau-
tionsº under ªOn-Vehicle Serviceº in air bag system section before performing service on or around
the air bag system components or wiring. Failure to follow WARNINGS could result in unintentional
activation of the system or could render the system inoperative. Either of these two conditions may
result in severe injury.
Technical service work must be started at least 90 seconds after the ignition switch is turned to the
ªLOCKº position and the negative cable is disconnected from the battery. Otherwise, the system may
be activated by reserve energy in the Sensing and Diagnostic Module (SDM).
CAUTION:
The air conditioning system of this vehicle uses refrigerant HFC-134a (R-134a).
None of refrigerant, compressor oil and component parts is interchangeable between two types of A / C:
one using refrigerant CFC-12 (R-12) and the other using refrigerant HFC-134a (R-134a).
Be sure to check which refrigerant is used before any service work including inspection and mainte-
nance. For identification between these two types, refer to the description in page 1B-2.
When replenishing or changing refrigerant and compressor oil and when replacing parts, make sure
that the material or the part to be used is appropriate to the A / C installed in the vehicle being serviced.
Use of incorrect one will result in leakage of refrigerant, damage in parts or other faulty condition.
For basic servicing method of the air conditioning system that is not described in this section, refer to AIR CONDI-
TIONING BASIC MANUAL (99520-02130).
CONTENTS
Page 83 of 801
YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-12 AIR CONDITIONING (OPTIONAL)
PERFORMANCE DIAGNOSIS
1) Confirm that vehicle and environmental conditions are as fol-
lows.
Vehicle is not exposed to direct sun.
Ambient temperature is within 15C ± 35C (59F ± 95F).
2) Make sure that high pressure valve (1) and low pressure valve
(2) of manifold gauge are firmly closed.
3) Connect high pressure charging hose (3) to high pressure ser-
vice valve (5) on vehicle, and connect low pressure charging
hose (4) to low pressure service valve (6) on vehicle.
4) Bleed the air in charging hoses (3), (4) by loosening their respec-
tive nuts on manifold gauge, utilizing the refrigerant pressure.
When a hiss is heard, immediately tighten nut.
CAUTION:
Do not interchange high and low pressure charging
hoses by mistake.
5) Warm up engine to normal operating temperature (engine cool-
ant temperature at 80 ± 90C (176 ± 194F)) and keep it at spe-
cified idle speed. (Radiator cooling fan should not be working
when checking pressure and temperature.)
6) Turn A / C switch ON, and set blower switch at ªHIº (4th position),
temperature control knob at ªCOOLº, air outlet control knob at
ªFACEº, fresh / circulation control knob at ªCIRCULATIONº.
(Confirm that A / C compressor and condenser fan are working.)
7) Keep all windows, doors and engine food open.
Ambient temperature
15 ± 35C (59F ± 95F)
Engine rpmKeep to 1,500 rpm.
Blower motor switchMax. (4th position)
Temperature controlMax. cool
Air outlet controlFace
Vehicle doorsAll open
Air inlet door positionRecirculation
8) With about 20 mm (0.8 in.) of dry bulb thermometer (1) inserted
into center duct air outlet and another one set near evaporator
air inlet, read temperature indicated on each thermometer.
Page 96 of 801
YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
AIR CONDITIONING (OPTIONAL) 1B-25
EVACUATING
EVACUATING PROCEDURE
CAUTION:
Do not evacuate before recovering refrigerant in system.
NOTE:
Whenever opened (exposed to atmospheric air), air condition-
ing system must be evacuated by using a vacuum pump. The
A / C system should be attached with a manifold gauge set, and
should be evacuated for approx. 15 minutes.
1) Connect high charging hose (1) and low charging hose (2) of
manifold gauge set (3) respectively as follows:
High Charging Hose (1)
High pressure charging valve (4)
on Discharge Hose
Low Charging Hose (2)i
Low pressure charging valve (5)
on Suction Pipe
2) Attach center charging hose (6) of manifold gauge set (3) to vac-
uum pump (7).
3) Operate vacuum pump (7), and then open discharge-side valve
(9) (Hi) of manifold gauge set (3).
If there is no blockage in the system, there will be an indication
on high pressure gauge (10).
When this occurs, open the other-side valve (8) (Lo) of the set.
4) Approx. 10 minutes later, low pressure gauge (11) should show
a vacuum lower than ± 760 mmHg providing no leakage exists.
NOTE:
If the system does not show a vacuum below ± 760 mmHg,
close both valves, stop vacuum pump and watch move-
ment of low pressure gauge.
Increase in the gauge reading suggests existence of leak-
age. In this case, repair the system before continuing its
evacuation.
If the gauge shows a stable reading (suggesting no leak-
age), continue evacuation.
5) Evacuation should be carried out for a total of at least 15 minutes.
6) Continue evacuation until low pressure gauge indicates a vacu-
um less than ± 760 mmHg, and then close both valves (8), (9).
7) Stop vacuum pump (7). Disconnect center charging hose (6) from
pump inlet. Now, the system is ready for charging refrigerant.
CHECKING SYSTEM FOR PRESSURE LEAKS
After completing the evacuation, close manifold gauge high pres-
sure valve (HI) and low-pressure valve (LO) and wait 10 minutes.
Verify that low-pressure gauge reading has not changed.
CAUTION:
If the gauge reading moves closer to ª0º, there is a leak
somewhere. Inspect the tubing connections, make neces-
sary corrections, and evacuate system once again, making
sure that there are no leaks.
Page 101 of 801
YH4
GRAND
VITARA
1. Suction hose
2. Discharge hose
3. Liquid pipe
4. Condenser outlet pipe
5. Expansion valve
6. Dual pressure switch
7. Suction pipe
: Apply compressor oil
(refrigerant oil) to O-ring.
1B-30 AIR CONDITIONING (OPTIONAL)
ON-VEHICLE SERVICE
WARNING:
Should refrigerant HFC-134a (R-134a) strike your eye(s), consult a doctor immediately.
DO NOT USE YOUR HAND TO RUB AFFECTED EYE(S).
Instead, use quantities of fresh cold water to splash it over affected area to thus gradually raise its
temperature above the freezing point.
Obtain proper treatment as soon as possible from a doctor or eye specialist.
Should liquid refrigerant HFC-134a (R-134a) get on your skin, such affected part should be treated
in the same manner as when skin is frostbitten or frozen.
CAUTION:
None of refrigerant, compressor oil and component parts is interchangeable between two types of A / C:
one using CFC-12 (R-12) and the other using HFC-134a (R-134a).
(For identification between these two types, refer to page 1B-2).
When replenishing or changing refrigerant and compressor oil and when replacing parts, make sure
that the material or the part to be used is appropriate to the A / C installed in the vehicle being serviced.
Use of incorrect one will result in leakage of refrigerant, damage in parts or other faulty condition.
PRECAUTION
When servicing air conditioning system, the following rules must be observed.
PIPING
When connecting hoses and pipes, apply a few drops of compressor oil (refrigerant oil) to seats of coupling nuts
and O-ring.
Never use heat for bending pipes. When bending a pipe, try to make its bending radius as slight as possible.
Keep internal parts of air conditioning free from moisture and dirt. When disconnecting any line from system,
install a blind plug or cap to the fitting immediately.
When tightening or loosening a fitting, use two wrenches, one for turning and the other for support.
Page 103 of 801
YH4
GRAND
VITARA
1. New compressor
2. Removed compressor
3. Excess oil (A ± B)
1B-32 AIR CONDITIONING (OPTIONAL)
REPLENISHING COMPRESSOR OIL
When replacing air conditioning parts with new ones, it is necessary
to replenish oil by the amount supposedly remaining in each part.
When changing gas only
When it is unavoidable to change gas without replacing any compo-
nent part for engine removal and installation or for some other rea-
son, replenish 20 cc oil. When replenishing gas only, oil replenish-
ment it not necessary.
When replacing compressor
Compressor oil is sealed in each new compressor by the amount
required for air conditioner cycle. Therefore, when using a new
compressor for replacement, drain oil from it by the amount calcu-
lated as follows.
ªCº = ªAº ± ªBº
ªCº: Amount of oil to be drained
ªAº: Amount of oil sealed in a new compressor
ªBº: Amount of oil remaining in removed compressor
When replacing other part
Replaced partAmount of compressor oil
to be replenished
Evaporator25 cc
Condenser15 cc
Receiver / dryer20 cc
Hoses10 cc each
Pipes10 cc each
Page 120 of 801
YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
2. High pressure side (Delivery side hose)
3. Lower pressure side (Suction side pipe)
AIR CONDITIONING (OPTIONAL) 1B-49
COMPRESSOR ASSEMBLY
CAUTION:
None of refrigerant, compressor oil and component parts is interchangeable between two types of A / C:
one using CFC-12 (R-12) and the other using HFC-134a (R-134a).
For identification between these two types, refer to page 1B-2.
When replenishing or changing refrigerant and compressor oil and when replacing parts, make sure
that the material or the part to be used is appropriate to the A / C installed in the vehicle being serviced.
Use of incorrect refrigerant or compressor oil will result in leakage of refrigerant, damage in parts or
other faulty condition.
PRECAUTION
When servicing the compressor, keep dirt or foreign material away from getting on or into the compressor parts
and system. Clean tools and a clean work area are important for proper service.
The compressor connection and the outside of the compressor should be cleaned before any ªOn-vehicleº repair
or before removal of the compressor. The parts must be kept clean at all times and any parts to be reassembled
should be cleaned with Trichloroethane, naphtha, kerosene or equivalent solvent and dried with dry air. Use only
lint free cloths to wipe parts.
The operations described are based on bench overhaul with compressor removed from the vehicle, except as
noted. They have been prepared in order of accessibility of the components.
When compressor is removed from the vehicle for servicing, the oil remaining in the compressor should be dis-
carded and new refrigerant oil added to the compressor.
Minor repair procedures may be done on the vehicle without discharging the system. Major repair procedures re-
quire that the system be discharged of refrigerant.
INSPECTION
1) Install manifold gauge set (1) as shown in the figure.
2) Close Hi (4) and Lo (5) hand valves.
3) Run engine at fast idle.
4) Check compressor assembly for following items.
If any of the above checks indicated a defect, repair compressor
assembly.
High pressure gauge reading is not low and low pressure
gauge reading is not higher than normal.
Metallic sound.
Leakage from shaft seal.
Page 144 of 801
YH4
GRAND
VITARA
1. Turning radius gauge1
FRONT END ALIGNMENT 3A-3
STEERING ANGLE
When tie rod end was replaced, check toe and then also steering
angle with turning radius gauges.
If steering angle is not correct, check if right and left tie-rods are
equal in length (ªAº in left figure).
Steering angle
inside: 35 3
outside: 33 3
NOTE:
If tie rod lengths were changed to adjust steering angle, rein-
spect toe-in.
Reference Information:
Side slip:
For inspecting front wheel side slip with side slip tester:
Side slip limit: Less than 3 mm / m
(Less than 0.118 in. / 3 ft)
If side slip exceeds above limit, toe-in or front wheel alignment may
out not be correct.
Page 147 of 801
YH4
GRAND
VITARA
1. Pin
2. Stub shaft (Rotor)
3. Torsion bar
4. Sleeve
5. Bearing
6. Pinion
7. Gear box
8. Rack
9. Ferrule
10. Valve case
POWER STEERING (P / S) SYSTEM 3B1-3
STEERING GEAR BOX
The steering gear box consists of two sections: one including a cyl-
inder and the other a valve. Main components of the cylinder sec-
tion are a gear box, a rack and a tube and those of the valve section
are a valve case, a sleeve and a stub shaft. The sleeve is linked with
the pinion through a pin and the valve and stub shaft are integrated
into one unit. Then the pinion and the stub shaft are linked to each
other by means of the torsion bar.
Thus, when the stub shaft moves, the valve changes its position,
thereby switching the hydraulic passage from the pump to the cylin-
der to help steering operation.
When turning the steering wheel feels heavy due to P / S fluid leak-
age or for some other reason (i.e., when in the manual steering
mode), the stub shaft and pinion are in direct linkage and the force
is output directly through the pinion and rack.
Page 258 of 801
YH4
GRAND
VITARA
WHEELS AND TIRES 3F-7
TIRE
MOUNTING AND DEMOUNTING
Use tire changing machine to mount or demount tires. Follow equip-
ment manufacturer's instructions. Do not use hand tools or tire
irons alone to change tires as they may damage tire beads or wheel
rim.
Rim bead seats should be cleaned with wire brush or coarse steel
wool to remove lubricants, old rubber and light rust. Before mount-
ing or demounting tire, bead area should be well lubricated with ap-
proved tire lubricant.
After mounting, inflate to 240 kPa (35psi) so that beads are com-
pletely seated. Then adjust pressure to specified shown an tire
placard.
WARNING:
Do not stand over tire when inflating. Bead may break when
bead snaps over rim's safety hump and cause serious per-
sonal injury.
Do not exceed 240 kPa (35 psi) pressure when inflating. If
240 kPa (35 psi) pressure will not seat beads, deflate, re-lu-
bricate and reinflate. Over inflation may cause bead to break
and cause serious personal injury.
Install valve core and inflate to proper pressure.
TIRE REPAIR
There are many different materials and techniques on the market
to repair tires. As not all of these work on all types of tires, tire
manufacturers have published detailed instructions on how and
when to repair tires. These instructions can be obtained from the
tire manufacturer.
Page 261 of 801
YH4
GRAND
VITARA
4A2-2 FRONT DRIVE SHAFT / SHAFT BEARING, OIL SEAL
DIAGNOSIS
DIAGNOSIS TABLE
ConditionPossible CauseCorrection
When starting:
Abnormal NoiseLoose wheel nuts.
Loose drive shaft flange bolts.
Broken or otherwise damaged wheel
bearing.Tighten wheel nuts.
Tighten drive shaft flange bolts.
Replace or change.
When making turns:
Abnormal NoiseGrease leakage from drive shaft joint
boot.
Worn or broken drive shaft joint.Replace joint boot and apply grease.
Replace drive shaft joint.
When running:
Abnormal NoiseBroken drive shaft joint.
Poorly lubricated or worn drive
shaft joint.
Loose drive shaft flange bolts.
Deformed drive shaft oil seal.Replace drive shaft joint.
Lubricate or replace joint.
Tighten drive shaft flange bolts.
Replace.
VibrationWorn drive shaft joint.
Deformed drive shaft oil seal.
Deformed drive shaft.Replace drive shaft joint.
Replace.
Replace.
DRIVE SHAFT BOOT AND JOINT CHECK
Check drive shaft boot for tear. If even a small tear is noted, replace
with new one.
Check drive shaft joint for wear, breakage and other damage and
replace if any defect exists.