transmission fluid SUZUKI GRAND VITARA 2004 2.G Service Owner's Manual
Page 461 of 801
YH4
GRAND
VITARA
1. Dipstick (G16 / J20)
2. Dipstick (H25)
AUTOMATIC TRANSMISSION (4 A / T) 7B1-59
ON-VEHICLE SERVICE
MAINTENANCE SERVICE
FLUID LEVEL
LEVEL CHECK AT NORMAL OPERATING TEMPERATURE
1) Stop vehicle and place it level.
2) Apply parking brake and place chocks against wheels.
3) With selector at P position, start engine.
4) Warm up engine till fluid temperature reaches normal operating
temperature (70 ± 80C / 158 ± 176F). As a guide to check fluid
temperature, warm up engine till engine coolant temperature
meter indicated around 1 unit above ªCº point.
5) Keep engine idling and shift selector slowly to L and back to P
position.
6) With engine idling, pull out dipstick, wipe it off with a clean cloth
and put it back into place.
7) Pull out dipstick again and check fluid level indicated on it. Fluid
level should be between FULL HOT and LOW HOT. If it is below
LOW HOT, add an equivalent of DEXRON-III up to FULL HOT.
Fluid specification
An equivalent of DEXRON-III
NOTE:
DO NOT RACE ENGINE while checking fluid level, even af-
ter the engine start.
DO NOT OVERFILL. Overfilling can causes foaming and
loss of fluid through breather. Then slippage and trans-
mission failure can result.
Bringing the level from LOW HOT to FULL HOT requires
0.3 liters (0.64/0.53 US/lmp.pt).
If vehicle was driven under high load such as pulling a
trailer, fluid level should be checked about half an hour af-
ter it is stopped.
Page 462 of 801
YH4
GRAND
VITARA
1. Dipstick (G16 / J20)
2. Dipstick (H25)
1. Drain plug
2. Propeller shaft
1. Dipstick (G16 / J20)
2. Dipstick (H25)
7B1-60 AUTOMATIC TRANSMISSION (4 A / T)
LEVEL CHECK AT ROOM TEMPERATURE
The fluid level check at room temperature performed after repair or
fluid change before test driving is just preparation for level check of
normal operating temperature. The checking procedure itself is the
same as that described previously. If the fluid level is between FULL
COLD and LOW COLD, proceed to test drive. And when the fluid
temperature has reached the normal operating temperature, check
fluid level again and adjust it as necessary.
FLUID CHANGE
1) Lift up vehicle.
2) With engine is cool, remove drain plug from oil pan and drain A / T
fluid.
3) Install drain plug.
Tightening Torque
(a): 23 N
.m (2.3 kg-m, 17.0 lb-ft)
4) Lower vehicle and fill proper amount of an equivalent of DEX-
RON-III.
5) Check fluid level according to procedure described under LEV-
EL CHECK NORMAL OPERATING TEMPERATURE.
Fluid specification
An equivalent of DEXRON-III
Fluid capacity
When draining
from drain plug
hole
2.5 liters (5.28/4.40 US/lmp.pt.)
When
overhauling
6.9 liters (14.58/12.14 US/lmp.pt.)
for G16
7.1 liters (15.00/12.50 US/lmp.pt.)
for J20 / H25
Page 467 of 801
YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-65
1. Drain plug
2. Propeller shaft
1. Oiler (with transmission fluid)
2. Solenoid valve
3. BatteryA: Hole (Should be dry)
B: Exhausting fluid Terminal Arrangement of PCM Coupler
(Viewed from harness side)
WITH BATTERY VOLTAGE WITHOUT BATTERY VOLTAGE
H25 Engine
Shift solenoid valve ± A (#1)C51-1-6
Shift solenoid valve ± B (#2)C51-1-1
TCC (Lock-up) solenoid valveC51-1-2
REMOVAL
1) Pull out dipstick and lift up vehicle.
2) With engine cooled, remove drain plug from oil pan and drain
A / T fluid.
3) Install drain plug with gasket.
Tightening Torque
(a): 23 N
.m (2.3 kg-m, 17.0 lb-ft)
4) Remove exhaust pipe bracket and disconnect front propeller
shaft from front differential (if equipped).
5) Remove oil pan bolts.
6) Remove oil pan.
7) Remove oil tubes.
8) Remove solenoid valve No.1 (shift solenoid valve A and B) or so-
lenoid valve No.2 (TCC solenoid valve).
OPERATION CHECK
Whenever shift solenoid valves and TCC (lock-up) solenoid valve
are removed from transmission, verify their valve function physical-
ly before they are reinstalled.
1) Apply oiler to solenoid valve and give compression by hands
and then check to be sure that transmission fluid from oiler does
not come out of holes in solenoid valve when battery voltage is
not conducted.
2) Under the same conditions as above, conduct battery voltage
and then make sure that fluid comes out with vigor.
NOTE:
If fluid does not come out with vigor in above step 2 in-
spection, do not re-use that solenoid valve.
Figure at the left shows shift solenoid valve check.
Check TCC solenoid valve also in the same way.
Page 468 of 801
YH4
GRAND
VITARA
7B1-66 AUTOMATIC TRANSMISSION (4 A / T)
14
2
3
INSTALLATION
Reverse removal procedure to install solenoid valves and noting
the following points.
For details of solenoid valve installation, refer to ªUnit Repairº
section. Use new gasket and O-ring.
Install oil tubes in such order as shown in figure.
For details of oil pan installation, refer to ªUnit Repairº section.
Use new oil pan gasket.
Tighten universal joint flange bolts & nuts and exhaust pipe brack-
et bolts to specified torque.
Fill A / T fluid and check fluid level according to procedure de-
scribed in ªCHANGING FLUIDº previously.
Check for fluid leakage after warming up A / T.
THROTTLE POSITION SENSOR
INSPECTION
Refer to SECTION 6E1 / 6E2 for inspection.
POWER / NORMAL CHANGE SWITCH
INSPECTION
Check Power / Normal change switch for operation referring to Step
4 of Diag. Flow Table B-4 in this section.
If malfunction is found, replace.
Page 469 of 801
YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-67
1. Oil cooler pipes
2. Union gaskets
3. Pipe bolt
OIL COOLER PIPES
REMOVAL
1) Lift up vehicle.
2) Make sure to wash dirt off from around pipe joints.
3) With engine is cool, loosen oil cooler pipe union bolts with oil out-
let union locked and remove oil cooler pipes from oil outlet
unions and hoses.
NOTE:
To avoid fluid leakage, plug open ends of oil outlet unions
and hoses right after they are disconnected.
INSTALLATION
1) Use new union gaskets and connect oil cooler pipes to oil outlet
unions.
2) Connect hoses to pipes and clamp them securely.
3) Tighten union bolts to specified torque with oil outlet union
locked.
Tightening Torque
(a): 35 N
.m (3.5 kg-m, 25.5 lb-ft)
4) Tighten pipe bolt securely.
5) Check A / T fluid level according to procedure described in ªFluid
Levelº section.
Add if necessary.
6) Check for fluid leakage after warming up A / T.
Page 477 of 801
YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-75
1. Drain plug
2. Filler and level plug
1. Drain plug
2. Front propeller shaft
1. Match marks
1. Right side transmission stiffener (if equipped)
G16 / J20
ON LIFT
1) Drain transfer oil for 4WD vehicle or A / T fluid for 2WD vehicle.
NOTE:
If 4WD automatic transmission is overhauled later on,
draining A / T fluid at this point will facilitate work.
Tightening Torque
(a): 23 N
.m (2.3 kg-m, 17.0 lb-ft)
2) Before removing propeller shaft, give match marks on joint
flange and propeller shaft as shown in left figure.
3) Remove universal joint flange bolts and take out rear propeller
shaft.
4) Likewise, take out front propeller shaft. (if equipped)
5) Remove nut from the end of select cable and bracket to set
cable free.
6) Remove select cable bracket by removing its 2 bolts.
7) Remove exhaust No.1 and No.2 pipe.
8) Remove transmission stiffener (right side) if equipped.
9) Unclamp and disconnect oil cooler hoses from pipes.
NOTE:
To avoid leakage of transmission fluid, plug open ends of
oil cooler pipes and hoses right after they are discon-
nected.
10) Remove torque converter housing lower plate.
11) Holding drive plate stationary with special tool or the like, re-
move torque converter mounting bolts with wrench.
Special Tool (only for G16 / J20)
(A): 09927-56010
Page 478 of 801
YH4
GRAND
VITARA
7B1-76 AUTOMATIC TRANSMISSION (4 A / T)
12) Remove engine to transmission nuts.
13) Disconnect connectors from VSS, output speed sensor, input
speed sensor, TR switch, shift & TCC solenoid valves and oth-
er electrical parts, and release their wire harness from clamps.
14) Apply transmission jack and take off rear mounting member by
removing its bolts.
15) With transmission (and transfer if equipped) assembly held up
on jack, move them to the rear and lower them including torque
converter.
WARNING:
Transmission (and transfer if equipped) assembly may
tilt rearward on jack. It is recommended to use an auxil-
iary arm of jack for the purpose of safety.
AFTER DISMOUNTING
WARNING:
Be sure to keep transmission (and transfer if equipped) as-
sembly horizontal throughout the work. Should they be
tilted, torque converter may fall off and cause personal inju-
ry and A / T fluid may flow out.
1) Remove breather hoses.
2) Remove transfer by removing its bolts, if equipped.
Page 479 of 801
YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-77
ªAº, (d)
1. Drive plate
2. Torque converter
3. Case right stiffener (if equipped)
4. Automatic transmissionTightening torque
(a): 50 N´m
5.0 kg-m
36.5 lb-ft
(b): 65 N´m
6.5 kg-m
47.0 lb-ft
(c): 85 N´m
8.5 kg-m
61.5 lb-ft
(d): 78 N´m
7.8 kg-m
56.5 lb-ft
1. Automatic transmission
2. Transfer (4WD)
3. Engine rear mounting
4. Engine rear mounting member Tightening torque
(a): 50 N´m (5.0 kg-m, 36.5 lb-ft) ªAº: Sealant 99000-31110
REMOUNTING
WARNING:
When moving transmission assembly with torque convert-
er equipped in it, be sure to keep it horizontal. Tilting it with
its front facing down may allow converter to fall off. Where-
by an injury may result.
For remounting, reverse dismounting procedure. Use specified
torque as given below and left.
Tightening torque
N.mkg-mlb-ft
Exhaust No.1 pipe to manifold
bolts or nuts505.036.5
Muffler to exhaust No.2 pipe
nuts606.043.5
Universal joint flange bolts and
nuts505.036.5
Oil filler tube bolts
Select cable bracket bolts232.317.0
Clamp wiring harness and hoses securely.
Refer to ªSelect Cableº section for adjusting procedure of select
cable.
Refer to ªA / T Throttle Cableº section for tuning of A / T throttle
cable.
Follow fluid level check procedure for refilling automatic transmis-
sion fluid and its level adjusting.
Connect battery, and confirm that engine and transmission func-
tion acceptably.
When remounting drive plate, use specified bolts.
Page 480 of 801
YH4
GRAND
VITARA
7B1-78 AUTOMATIC TRANSMISSION (4 A / T)
ON-VEHICLE
SERVICE MOUNTING
EXTERNAL
UNIT REPAIR
Refer to the same section of UNIT REPAIR MANUAL mentioned in FOREWORD of this manual.
TIGHTENING TORQUE SPECIFICATIONS
Fastening portion
Tightening torque
Fastening portion
N´mkg-mlb-ft
Automatic transmission fluid drain plug232.317.0
Transfer oil filler / level and drain plugs232.317.0
Transmission case plug171.712.5
Manual select lever nut131.39.5
Manual select cable nut70.75.5
Manual selector assembly bolts181.813.5
Transmission to engine bolts and nuts858.561.5
Engine rear mounting bolts
Engine rear mounting member bolts
Transmission case right stiffener bolts
505.036.5
Universal joint flange bolts and nuts505.036.5
Torque converter mounting bolts656.547.0
Adapter case or extension case bolts
(G16 engine)353.525.5
Adapter case or extension case bolts
(J20 / H25 engines)424.230.0
Transmission range switch lock bolt5.50.554.0
Oil pipe union bolts353.522.5
Drive plate bolts787.856.5
Interlock cable clamp screw2.20.221.5
Interlock cable outer mounting nut131.39.5
Page 481 of 801
YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-79
09925-37810
Oil pressure gauge09927-56010
Gear stopper
(only for G16 / J20)09931-76030
16 / 14 pin DLC
(OBD-II adapter) cable
09931-76011
SUZUKI scan tool (Tech 1A) kit1. Storage case
2. Operator's manual
3. Tech 1A
4. DLC cable
5. Test lead / probe
6. Power source cable
7. DLC cable adapter
8. Self±test adapterMass storage cartridge
REQUIRED SERVICE MATERIALS
MATERIALRECOMMENDED
SUZUKI PRODUCTUSE
A / T fluidAn equivalent of DEXRON-IIIAutomatic transmission
Parts lubrication when installing
Lithium greaseSUZUKI SUPER GREASE A
(99000±25010)Cable ends
SealantSUZUKI BOND NO.1215
(99000-31110)Flywheel bolts
SPECIAL TOOLS