steering wheel SUZUKI SWIFT 2000 1.G SF310 Service User Guide
Page 323 of 557
1. Rotor plate
2. Inner rotor:
Apply thin coat of engine oil.
3. Outer rotor:
Apply thin coat of engine oil.
4. Gasket
5. Pin
6. Pin
7. Relief valve:
Apply thin coat of engine oil.
8. Spring
9. Retainer
10. Retainer ring
11. Front oil seal:
Apply engine oil to contact
part of crankshaft with oil seal lip.
12. Plate screw
13. Bolt (short)
14. Bolt (long)
: Tightening Torque
: Do not reuse
6A1-28 ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE)
OIL PUMP
REMOVAL
1) Disconnect negative cable at battery.
2) Remove timing belt as previously outlined.
3) Remove generator and its bracket.
NOTE:
When installing bracket, fasten nut (A) first.
4) Remove power steering pump bracket or A / C compressor
bracket, if equipped.
NOTE:
When installing bracket, fasten bolt (B) first.
5) Remove oil pan and oil pump strainer as previously outlined.
6) Remove crankshaft timing belt pulley (3).
Lock crankshaft inserting flat end rod or the like (1) between fly-
wheel ring gear and transmission case.
With crankshaft locked, remove crankshaft timing belt pulley
bolt (2).
Page 408 of 557
ENGINE AND EMISSION CONTROL SYSTEM (TBI FOR G10) 6E1-17
1. ECM
2. Instrument panel
3. Steering wheel
1. Injector wire
2. Screws
1. Stay
3) Make sure that injector wire O-ring is free from any damage and
deterioration, and apply thin coat of spindle oil or gasoline to O-
ring.
Install injector wire and tighten new wire screw to specified
torque.
Tightening Torque
(a): 3.5 N
.m (0.35 kg-m, 2.5 lb-ft)
4) Connect battery negative cable at battery.
5) With engine “OFF” and ignition switch “ON”, check for fuel leaks.
6) Install air cleaner mounting stay as shown left.
7) Install air cleaner assembly referring to Section 6A.
ELECTRONIC CONTROL SYSTEM
ENGINE CONTROL MODULE (ECM)
CAUTION:
As ECM consists of precision parts, be careful not to ex-
pose it to excessive shock.
REMOVAL
1) Disconnect battery negative cable at battery.
2) Lower fuse box after removing bolt.
3) Disconnect couplers from ECM while releasing coupler lock.
4) Remove ECM from body.
INSTALLATION
1) Install ECM to body.
2) Connect couplers to ECM securely.
3) Install fuse box and tighten its bolt.
4) Connect battery negative cable at battery.