starting SUZUKI SWIFT 2008 2.G Service Repair Manual
Page 403 of 1496
Downloaded from www.Manualslib.com manuals search engine Starting System:  1I-2
ConditionPossible cause Correction / Reference Item
Motor not running (No 
operating sound of 
magnetic switch) Shift lever switch is not in P or N, or not 
adjusted (A/T)
Shift in P or N, or 
adjust switch. (A/T)
Battery run down Recharge battery.
Battery voltage too low due to battery 
deterioration Replace battery.
Poor contact in battery terminal 
connection Retighten or replace.
Loose grounding cable connection Retighten.
Fuse set loose or blown off Tighten or replace.
Poor contacting action of ignition switch 
and magnetic switch Replace.
Lead wire coupler loose in place Retighten.
Open-circuit between ignition switch and 
magnetic switch Repair.
Open-circuit in pull-in coil Replace magnetic switch.
Brushes are seating poorly or worn 
down Repair or replace.
Poor sliding of plunger and/or pinion Repair.
Faulty starting motor control relay “Main Relay, Fuel Pump Relay and Starting 
Motor Control Relay Inspection in Section 1C”.
Faulty ECM and its circuit “Inspection of ECM and Its Circuits in Section 
1A”.
Motor not running 
(Operating sound of 
magnetic switch heard) Battery run down
Recharge battery.
Battery voltage too low due to battery 
deterioration Replace battery.
Loose battery cable connections Retighten.
Burnt main contact point, or poor 
contacting action of magnetic switch Replace magnetic switch.
Brushes are seating poorly or worn 
down Repair or replace.
Weakened brush spring Replace.
Burnt commutator Replace armature.
Layer short-circuit of armature Replace.
Crankshaft rotation obstructed Repair.
Starting motor running 
but too slow (small 
torque) (If battery and 
wiring are satisfactory, 
inspect starting motor) Insufficient contact 
of magnetic switch 
main contacts Replace magnetic switch.
Layer short-circuit of armature Replace.
Disconnected, burnt or worn 
commutator Repair commutator or replace armature.
Worn brushes Replace brush.
Weakened brush springs Replace spring.
Burnt or abnormally worn end bush Replace bush.
Starting motor running, 
but not cranking engine Worn pinion tip
Replace over-running clutch.
Poor sliding of over-running clutch Repair.
Over-running clutch slipping Replace over-running clutch.
Worn teeth of ring gear Replace flywheel (M/T) or drive plate (A/T).
Noise Abnormally worn bush Replace bush.
Worn pinion or worn teeth of ring gear Replace over-running clutch, flywheel (M/T) or 
drive plate (A/T).
Poor sliding of pinion (failure in return 
movement) Repair or replace.
Worn internal or planetary gear teeth Replace.
Lack of oil in each part Lubricate.
Starting motor does not 
stop running Fused contact points of magnetic switch
Replace magnetic switch.
Short-circuit between turns of magnetic 
switch coil (layer short-circuit) Replace magnetic switch.
Failure of returning action in ignition 
switch Replace.  
Page 404 of 1496
Downloaded from www.Manualslib.com manuals search engine 1I-3 Starting System: 
Cranking System TestS7RS0B1904002
CAUTION! 
Each test must be performed within 3 – 5 
seconds to avoid coil from burning.
 
Pull-In Test
Connect battery to the magnetic switch as shown.
Check that plunger and pinion move outward.
If plunger and pinion don’t move, replace the magnetic 
switch.
NOTE
Before testing, disconnect lead wire from 
terminal “M” (2).
 
Hold-In Test
While connected as the figure with plunger out, 
disconnect negative lead from terminal “M”.
Check that plunger and pinion remain out.
If plunger and pinion return  inward, replace the magnetic 
switch. Plunger and Pinion Return Test
Disconnect negative lead from starting motor body.
Check that plunger and pinion return inward.
If plunger and pinion don’t return, replace the magnetic 
switch.
No-Load Performance Test
Connect battery and ammeter to starter as shown.
Check that starter rotates 
smoothly and steadily with 
pinion moving out. Check that ammeter indicates 
specified current.
Specified current  (No-load performance test)
90 A MAX. at 11 V
1. Terminal “S”
3. Lead wire (switch to motor)
I2RH01190002-01
I2RH01190003-01
I2RH01190004-01
I2RH01190005-01  
Page 405 of 1496
Downloaded from www.Manualslib.com manuals search engine Starting System:  1I-4
Repair Instructions
Starting Motor Dismounting and RemountingS7RS0B1906001
Dismounting1) Disconnect negative (–) battery lead at battery.
2) Disconnect magnetic switch lead wire (1) and battery cable (2) from starting motor terminals.
3) Detach shift & select control cable bracket from transaxle. (M/T model only)
4) Remove starting motor mount bolt (3) and nut (4).
5) Remove starting motor (5).
Remounting
Reverse the dismounting procedure noting the following.
• Tighten battery cable nut (6) to specified torque.
Tightening torque
Starting motor battery cable nut (a):  9.8 N·m (0.98 kgf-m, 7.0 lb-ft)
I4RS0A190002-01
: 9.8 N ⋅m (0.98 kgf-m, 7.0 lb-ft)  
Page 406 of 1496
Downloaded from www.Manualslib.com manuals search engine 1I-5 Starting System: 
Starting Motor ComponentsS7RS0B1906002
I4RS0A190003-01
1. Front housing 7. Plate  13. Planetary gear 19. Rear bush
 2. Bush  8. Seal rubber  14. Packing 20. Starting motor battery cable nut
3. Pinion stop ring 9. Magnetic switch  15. Yoke :9.8 N
⋅m (0.98 kgf-m, 7.0 lb-ft)
4. Over-running clutch 10. Ball 16. Armature: Do not reuse.
5. Lever 11. Internal gear 17. Brush assembly : Apply grease 99000-25010 to sliding surface of each part.
6. Plunger  12. Planetary carrier shaft 18. Rear bracket  
Page 407 of 1496
Downloaded from www.Manualslib.com manuals search engine Starting System:  1I-6
Starting Motor InspectionS7RS0B1906003
Plunger
Inspect plunger for wear. Replace if necessary.
Magnetic Switch
Push in plunger and release it. The plunger should 
return quickly to its original position. Replace if 
necessary.
Pull-in coil open circuit test
Check for continuity across magnetic switch “S” terminal 
(1) and “M” terminal (2). If no continuity, coil is open and 
should be replaced. Hold-in coil open circuit test
Check for continuity across ma
gnetic switch “S” terminal 
(1) and coil case. If no continuity, coil is open and should 
be replaced.
Rear Bracket Bush
Inspect bush for wear or damage. Replace if necessary.
Brush
• Check brushes for wear. Measure length of brushes and if below the limit, 
replace the brush.
Brush length
Standard: 12.3 mm (0.48 in.)
Limit: 7.0 mm (0.28 in.)
• Install brushes to each brush holder and check for  smooth movement.
I2RH01190008-01
I2RH01190009-01
I2RH01190010-01
I2RH01190011-01
I2RH01190012-01
I2RH01190013-01  
Page 408 of 1496
Downloaded from www.Manualslib.com manuals search engine 1I-7 Starting System: 
Spring
Inspect brush springs for wear, damage or other 
abnormal conditions. Replace if necessary.
Brush spring tension
Standard: 2.2 kg (4.85 lb)
Limit: 0.6 kg (1.33 lb)
Brush Holder
• Check movement of brush in brush holder. If brush movement within brush holder is sluggish, check 
brush holder for distortion and sliding faces for 
contamination.
Clean or correct as necessary.
• Check for continuity across insulated brush (positive  side) and grounded brush (negative side).
If continuity exists, brus h holder is grounded due to 
defective insulation and should be replaced.
Armature
• Inspect commutator for dirt or burn. Correct with  sandpaper or lathe, if necessary.
• Check commutator for uneven wear with armature (1)  supported on V-blocks (2). If deflection of dial gauge 
(4) pointer exceeds limit, repair or replace.
NOTE
The following specification presupposes that 
the armature is free from bend. Bent 
armature must be replaced.
 
Commutator out of round
Standard: 0.05 mm (0.002 in.) or less
Limit: 0.4 mm (0.016 in.) • Inspect the commutator for wear. If diameter is below 
limit, replace the armature.
Commutator outside diameter
Standard: 29.4 mm (1.16 in.)
Limit: 28.8 mm (1.14 in.)
• Inspect the commutator (1) for insulator (2) depth.  Correct or replace if below limit.
Commutator insulator depth “a”
Standard: 0.4 – 0.6 mm (0.016 – 0.023 in.)
Limit: 0.2 mm (0.008 in.)
I4RS0A190004-01
I2RH01190015-01
3. Magnetic stand
[A]: Correct
[B]: Incorrect
I2RH01190016-01
I2RH01190017-01
I3RH0A190005-01  
Page 409 of 1496
Downloaded from www.Manualslib.com manuals search engine Starting System:  1I-8
• Check the commutator and armature core. If there is 
continuity, the armature is grounded and must be 
replaced.
• Check for continuity between segments. If there is no  continuity at any test point , there is an open circuit 
and the armature must be replaced.
Gears
Inspect the internal gear and the planetary gears for 
wear, damage or other abnorma l conditions. Replace if 
necessary. Pinion and Over-Running Clutch
• Inspect the pinion for wear, damage or other abnormal 
conditions.
Check that clutch locks up when turned in direction of 
drive and rotates smoothly in reverse direction. 
Replace if necessary.
• Inspect the spline teeth for wear or damage. Replace  if necessary.
Inspect the pinion for smooth movement.
Front Housing Bush
Inspect the bush for wear or damage. Replace if 
necessary.
I2RH01190019-01
I2RH01190020-01
I2RH01190021-01
I2RH01190022-01
I2RH01190023-01
I2RH01190024-01  
Page 410 of 1496
Downloaded from www.Manualslib.com manuals search engine 1I-9 Starting System: 
Specifications
Cranking System SpecificationsS7RS0B1907001
Tightening Torque SpecificationsS7RS0B1907002
NOTE
The specified tightening torque is also described in the following.
“Starting Motor Dismounting and Remounting”
“Starting Motor Components”
 
Reference:
For the tightening torque of fastener not specified in this section, refer to “Fasteners Information in Section 0A”.
Special Tools and Equipment
Recommended Service MaterialS7RS0B1908001
NOTE
Required service material is also described in the following.
“Starting Motor Components”
 
Voltage 12 volts
Output 1.2 kW
Rating 30 seconds
Direction of rotation Clockwise as viewed from pinion side
Brush length Standard: 12.3 mm (0.48 in.) Limit: 7.0 mm (0.28 in.)
Number of pinion teeth 8
Performance Condition Guarantee
Around at 20  °C 
(68  °F) No load characteristic 11.0 V
90 A maximum
2370 r/min minimum
Load characteristic 7.5 V
300 A 10.65 N
⋅m (1.065 kgf-m, 7.70 lb-ft) minimum
840 r/min minimum
Locked characteristic 4.0 V 780 A maximum
20 N
⋅m (2.0 kgf-m, 14.5 lb-ft) minimum
Magnetic switch operating voltage 8 volts maximum
Fastening part Tightening torque
Note
N ⋅mkgf-mlb-ft
Starting motor battery cable nut 9.8 0.98  7.0  )  
Page 414 of 1496
Downloaded from www.Manualslib.com manuals search engine 1J-4 Charging System: 
Diagnostic Information and Procedures
Battery InspectionS7RS0B1A04001
Common Causes of Failure
A battery is not designed to last indefinitely; however, with proper care,  it will provide many years of service. If the 
battery performs satisfactorily during te st but fails to operate properly for no apparent reason, the following are some 
factors that may point to the cause of trouble:
• Accessories left on overnight or for an extended period without the generator operating.
• Slow average driving speeds for short periods.
• Electrical load exceeding generator output partic ularly with addition of aftermarket equipment.
• Defects in charging system such as high resistance, s lipping drive belt, loose generator output terminal, faulty 
generator or voltage regulator, Refer to “Generator Symptom Diagnosis”.
• Battery abuse, including failure to keep battery cable terminals clean and tight or loose battery hold down.
• Mechanical problems in electrical sys tem such as shorted or pinched wires.
Visual Inspection
Check for obvious damage, such as cracked or broken case  or cover, that could permit loss of electrolyte. If obvious 
damage is noted, replace battery. Determine  cause of damage and correct as needed.
Generator Symptom DiagnosisS7RS0B1A04002
CAUTION! 
• Do not mistake polarities of “IG” terminal and “L” terminal.
• Do not create short circuit between “IG” and “L” terminals. Always connect these terminals through  a lamp.
• Do not connect any load between “L” and “E” terminals.
• When connecting charger or booster battery to vehicle battery, refer to “Jump Starting in Case of  Emergency”.
 
Trouble in charging system  will show up as one or more  of the following conditions:
1) Faulty indicator lamp operation.
2) An undercharged battery as evidenced  by slow cranking or indicator dark.
3) An overcharged battery as evidenced by ex cessive spewing of electrolyte from vents.
Condition Possible cause Correction / Reference Item
Noisy generator Loose drive belt Adjust or replace drive belt.
Loose drive belt pulley Tighten by specified torque.
Loose mounting bolts Tighten by specified torque.
Worn or dirty bearings Replace.
Defective diode or stator Replace.
Charge light does not 
light with ignition ON and 
engine off Fuse blown
Replace fuse and check for shorted circuit.
Indicator lamp (LED) faulty Replace combination meter.
Wiring connection loose Tighten loose connection.
IC regulator or field coil faulty Replace.
Poor contact between brush and slip 
ring Repair or replace.
Charge light does not go 
out with engine running 
(battery requires frequent 
recharging) Drive belt loose or worn
Adjust or replace drive belt.
IC regulator or generator faulty Replace.
Wiring faulty Repair wiring.  
Page 415 of 1496
Downloaded from www.Manualslib.com manuals search engine Charging System:  1J-5
Generator Test (Undercharged Battery Check)S7RS0B1A04003
This condition, as evidenced by slow cranking or 
indicator clear with dark or light yellow dot can be 
caused by one or more of the following conditions even 
though indicator lamp may be operating normal.
The following procedure also applies to cars with 
voltmeter and ammeter.1) Make sure that undercharged condition has not been  caused by accessories left on for extended period of 
time.
2) Check drive belt for proper tension.
3) If battery defect is suspected, refer to “Battery  Description”.
4) Inspect wiring for defects. Check all connections for  tightness and cleanliness,  battery cable connections 
at battery, starting motor, ignition ground cable and 
no “C” terminal circuit at ground.
5) Connect switch (6), load (5), battery (4), voltmeter  (3) and ammeter (2) to generator (1) as shown in 
figure.
Voltmeter: Set between  generator “B” terminal 
and ground.
Ammeter: Set between  generator “B” terminal 
and battery (+) terminal.
NOTE
Use fully charged battery.
 
6) Measure current and voltage.
No-Load Check 1) Run engine from idling up to 2000 rpm and read  meters.
NOTE
Turn off switches of all accessories (wiper, 
heater etc.).
 
Specification for undercharged battery (No-load 
check)
Current: 10 A
Voltage: 14.2 – 14.8 V (at 20  °C, 68  °F)
NOTE
Consideration should be taken that voltage 
will differ somewhat with regulator case 
temperature as shown in figure.
 
2) Using service wire, ground “C” terminal (1) of 
generator.
3) Measure voltage between “B” terminal of generator  and body ground.
Voltage: 12.5 – 13.1 V (at 20  °C, 68  °F)
• If voltage is higher than standard value
If voltage is higher than standard value, check ground 
of brushes.
If brushes are not grounded, replace IC regulator.
If voltage is lower than standard value, proceed to the 
following check.
Load Check 1) Run engine at 2000 rpm and turn on head light and  blower motor.
2) Measure current. If measure current is less than 30 A, repair or 
replace generator.
IYSQ011A0007-01
[A]: Regulated voltage (V)
[B]: Heat sink temperature ( °C)
16.0
15.5
15.0
14.5
14.0
13.5
13.0
-30 0 20
[A]
[B]
68
 22120 (˚C)
248 (˚F)
(V)
I6RS0B1A1002-01
I5JB0A1A0011-01