O2 sensor TOYOTA SEQUOIA 2001 Service Repair Manual

Page 2457 of 4323

I28261
± DIAGNOSTICSNAVIGATION SYSTEM
DI±2255
2449 Author: Date:
2005 SEQUOIA (RM1146U)
Speed signal error
INSPECTION PROCEDURE
1 Navigation check mode (Vehicle sensors check).
CHECK:
(a) Enter the ºNavigation Checkº mode (Vehicle Sensors)
(See page DI±2180).
(b) While driving, compare the ºSPDº indicator to the reading
on the speedometer. Check if these readings are almost
the same.
OK:
The readings are almost the same.
OK Replace radio and navigation assy.
NG
Proceed to next circuit inspection shown in diagnostic trouble code chart (See page DI±2203).
DIDD9±01

Page 2462 of 4323

I28766
R6
Light Control
Rheostat AssyRadio and Navigation Assy
J/C
Steering Pad Switch Assy
Spiral Cable
Sub±assy From
TAILLIGHT
RelayILL±
SWG J/C
ILL+ W±G
GJ39 J40
J39 J40
J39 J40W±G
G
G
G A B
A
AAB
ILL±
T12
2
6 1
10C9±1
BR±W
C9±10 6
4
Steering SWR30
R27 R30 DI±2260
± DIAGNOSTICSNAVIGATION SYSTEM
2454 Author: Date:
2005 SEQUOIA (RM1146U)
Illumination circuit
CIRCUIT DESCRIPTION
Power is supplied to the radio and navigation panel illumination when the light control switch is in the TAIL
or HEAD position. The body ECU determines the external brightness based on the brightness level detected
by the automatic light control sensor, and then operates the TAILLIGHT relay. Power can also be supplied
by operating the relay.
The intensity of the radio receiver panel illumination can be adjusted by the rheostat switch.
WIRING DIAGRAM
DIDDF±01

Page 2494 of 4323

I28748SPD
Wire Harness View:
R29
4.5 to 14 V
0
Turn the wheel Below 2 V
DI±2292
± DIAGNOSTICSNAVIGATION SYSTEM
2486 Author: Date:
2005 SEQUOIA (RM1146U)
INSPECTION PROCEDURE
1 Check operation of speedometer.
CHECK:
Drive the vehicle and check if the function of the speedometer in the combination meter is normal.
OK:
Actual vehicle speed and the speed indicated on the speedometer and the same.
HINT:
The vehicle speed sensor is functioning normally when the indication on the speedometer is normal.
NG Check combination meter assy
(See page DI±1645).
OK
2 Inspect combination meter assy.
PREPARATION:
Disconnect the radio and navigation assy connector.
CHECK:
(a) Move the shift lever to the neutral position.
(b) Jack up either one of the front wheels.
(c) Turn the ignition switch on.
(d) Measure the voltage between terminal SPD and body
ground of the radio and navigation assy when the front
wheels are turned slowly.
OK:
Voltage is pulses as shown below.
OK Replace radio and navigation assy.
NG

Page 2501 of 4323

DIDKN±01
I28851
R/B No. 2
 Heater Main Relay
(Marking: HTR)
Compressor
Condenser
Receiver Pressure Switch
Integration Panel Assembly
 A/C ECU
 A/C Switch
 Air Inlet Selector
Heater Unit
 Heater Radiator
 Air Mix Servomotor
 Air Outlet Servomotor
Cooling Unit
 Blower Motor Linear
Controller
 Evaporator
 Expansion Valve
 ThermistorBlower Unit
 Blower Motor
 Air Inlet Servomotor
Water Valve
Rear Heater
Control Assembly
Condenser Fan
Ambient
Temperature
Sensor
Solar Sensor
Room
Temperature
Sensor
Rear Room Temperature
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2299
2493 Author: Date:
2005 SEQUOIA (RM1146U)
LOCATION

Page 2505 of 4323

DIDKO±01
I15897R/F SW
I15897DEF. SW
STEP
1
2
3
4
5
6
7
8
9
10DISPLAY
CODE
Fr
BLOWER
LEVELFr
OUTLETINLET
COMPRESSORFr A/M
DAMPERRr
BLOWER
LEVELRr
OUTLETRr A/M
DAMPER
1
2
3
4
5
6
7
8
9 0
1 0
16
31FACE
B/L
FOOT
F/D
DEFFRS
R/F (50%)
RECOFF
ON±14%
50.0%
113.5%1 0
10
31FACE1
FACE2
B/L1
B/L2
FOOT0.0%
40.0%
60.0%
86.5%
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2303
2497 Author: Date:
2005 SEQUOIA (RM1146U)
ACTUATOR CHECK
1. ACTUATOR CHECK
(a) After entering the sensor check mode, press the R/F
switch (See page DI±2312).
(b) Since each damper, motor and relay automatically oper-
ates at 1 second intervals beginning in order from 20 in
the temperature display, check the temperature and air
flow visually and by hand.
If a slower display is desired, press the DEF. (Fr.) switch
and change it to step operation. Each time the DEF. (Fr.)
switch is pressed, the display changes by 1 step.
HINT:
Codes are displayed in order from the smallest to the larg-
est numbers.
To cancel the check mode, press the OFF switch.

Page 2506 of 4323

DI3F3±10
DI±2304
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2498 Author: Date:
2005 SEQUOIA (RM1146U)
PROBLEM SYMPTOMS TABLE
Front A/C:
SymptomSuspected AreaSee page
Whole functions of the A/C system do not operate4. Integration control and panel
5. IG power source circuitIN±35
DI±2363
Air Flow Control: No blower operation
1. IG power source circuit
2. Heater main relay
3. Blower motor circuit
4. Integration control and panel
5. Blower motor controllerDI±2363
AC±95
DI±2374
IN±35
AC±83
Air Flow Control: No blower control
1. Blower motor circuit
2. Integration control and panel
3. Solar sensor circuit
4. Blower motor controllerDI±2374
IN±35
DI±2336
AC±83
Air Flow Control: Insufficient air flow1. Blower motor circuitDI±2374
Temperature Control: No cool air comes out
1. Refrigerant volume
2. Drive belt tension
3. Refrigeration system inspection with manifold gauge set
4. Compressor circuit
5. Pressure switch circuit
6. Front air mix damper position sensor circuit
7. Front air mix damper control servomotor circuit
8. Front room temp. sensor circuit
9. Ambient temp. sensor circuit
10.Vehicle speed signal circuit
11. Integration control and panelAC±23
AC±15
AC±3
DI±2381
DI±2342
DI±2346
DI±2355
DI±2319
DI±2322
DI±2370
IN±35
Temperature Control: No warm air comes out
1. Front air mix damper position sensor circuit
2. Front air mix damper control servomotor circuit
3. Front room temp. sensor circuit
4. Ambient temp. sensor circuit
5. Vehicle speed signal circuit
6. Front evaporator temp. sensor circuit
7. Integration control and panelDI±2346
DI±2355
DI±2319
DI±2322
DI±2370
DI±2325
IN±35
Temperature Control: Output air is warmer or cooler than the set
temperature or response is slow
1. Refrigerant volume
2. Drive belt tension
3. Refrigeration system inspection with manifold gauge set
4. Cooling fan system
5. Solar sensor circuit
6. Front room temp. sensor circuit
7. Ambient temp. sensor circuit
8. Vehicle speed signal circuit
9. Front evaporator temp. sensor circuit
10.Front air mix damper position sensor circuit
11. Front air mix damper control servomotor circuit
12.Front air inlet damper position sensor circuit
13.Front air inlet damper control servomotor circuit
14.Condenser
15.Evaporator
16.Heater radiator
17.Expansion valve
18.Integration control and panelAC±23
AC±15
AC±3
AC±96
DI±2336
DI±2319
DI±2322
DI±2370
DI±2325
DI±2346
DI±2355
DI±2349
DI±2358
AC±65
AC±24
AC±35
AC±29
IN±35

Page 2507 of 4323

± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2305
2499 Author: Date:
2005 SEQUOIA (RM1146U)Symptom
Suspected AreaSee page
Temperature Control: No temperature control (only Max. cool or
Max. warm)
1. Front room temp. sensor circuit
2. Ambient temp. sensor circuit
3. Front air mix damper position sensor circuit
4. Front air mix damper control servomotor circuit
5. Integration control and panelDI±2319
DI±2322
DI±2346
DI±2355
IN±35
No air inlet control
1. Front air inlet damper position sensor circuit
2. Front air inlet damper control servomotor circuit
3. Integration control and panelDI±2349
DI±2358
IN±35
No air flow control
1. Air outlet damper position sensor circuit
2. Air outlet damper control servomotor circuit
3. Integration control and panelAC±35
AC±35
IN±35
Engine idle up does not occur, or is continuous1. Compressor circuit
2. ECMDI±2381
DI±34
No DTC is recorded. Set mode is cleared when IG switch is
turned off.1. Back±up power source circuit
2. Integration control and panelDI±2366
IN±35
Rear A/C:
SymptomSuspected AreaSee page
Whole functions of the rear A/C system do not operate
1. Heater control assembly
2. Integration control and panel
3. ACC power source circuitIN±35
DI±2368
DI±2368
Air Flow Control: No blower operation
1. ACC power source circuit
2. Rear heater main relay
3. Rear blower motor
4. Rear blower motor controller
5. Heater control assembly
6. Integration control and panelDI±2368
AC±95
AC±45
±
IN±35
DI±2368
Air Flow Control: No blower control
1. Rear heater main relay
2. Rear blower motor
3. Rear blower motor controller
4. Heater control assembly
5. Integration control and panel
6. Solar sensor circuitAC±95
AC±45
±
IN±35
DI±2336
DI±2368
Air Flow Control: Insufficient air flow1. Rear blower motor
2. Rear blower resisterAC±45
±
Temperature Control: No cool air comes out
1. Refrigerant volume
2. Drive belt tension
3. Refrigeration system inspection with manifold gauge set
4. Compressor circuit
5. Pressure switch circuit
6. Water valve damper position sensor circuit
7. Water valve damper control servomotor circuit
8. Rear room temp. sensor circuit
9. Ambient temp. sensor circuit
10.ECM
11. Heater control assembly
12.Integration control and panelAC±23
AC±15
AC±3
DI±2381
DI±2342
DI±2352
DI±2361
DI±2333
DI±2322
DI±34
DI±2368
IN±35
Temperature Control: No warm air comes out
1. Water valve damper position sensor circuit
2. Water valve damper control servomotor circuit
3. Rear room temp. sensor circuit
4. Ambient temp. sensor circuit
5. Rear evaporator temp. sensor circuit
6. Heater control assembly
7. Integration control and panelDI±2352
DI±2361
DI±2333
DI±2322
DI±2330
IN±35
IN±35

Page 2508 of 4323

DI±2306
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2500 Author: Date:
2005 SEQUOIA (RM1146U) Temperature Control: Output air is warmer or cooler than the set
temperature or response is slow
1. Refrigerant volume
2. Drive belt tension
3. Refrigeration system inspection with manifold gauge set
4. Cooling fan system
5. Solar sensor circuit
6. Rear room temp. sensor circuit
7. Ambient temp. sensor circuit
8. Rear evaporator temp. sensor circuit
9. Water valve damper position sensor circuit
10.Water valve damper control servomotor circuit
11. Condenser
12.Evaporator
13.Heater radiator
14.Expansion valve
15.Heater control assembly
16.Integration control and panelAC±23
AC±15
AC±3
AC±96
DI±2336
DI±2333
DI±2322
DI±2330
DI±2352
DI±2361
AC±65
AC±70
AC±45
AC±76
IN±35
IN±35
Temperature Control: No temperature control (only Max. cool or
Max. warm)
1. Rear room temp. sensor circuit
2. Ambient temp. sensor circuit
3. Water valve damper position sensor circuit
4. Water valve damper control servomotor circuit
5. Heater control assembly
6. Integration control and panelDI±2333
DI±2322
DI±2352
DI±2361
IN±35
IN±35

Page 2509 of 4323

DIDKP±01
I15876
I21 I20I19
I22
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2307
2501 Author: Date:
2005 SEQUOIA (RM1146U)
TERMINALS OF ECU
Integration Control and Panel
Symbols (Terminals No.)Wiring ColorTerminal DescriptionConditionSpecified Condition
+B eGND
(I19±1 e I19±10)R e OPower source (Back±up)Always10 to 14 V
IG+ e GND
(I19±2 e I19±10)R±L e OPower source (IG)IG switch OFF " ON10 to 14 V
PSW e GNDLBOPithil
A/C refrigerant pressure: less than
0.19 MPa
(2.0 kgf/cm2)10 t 14B l 10VPSW e GND
(I19±6 e I19±10)L±B e OPressure switch signal0.19 MPa (2.0 kgf/cm)
or more than 3.14 MPa (32
Kgf/cm2)
10 to 14 " Below 1.0 V
HR e GND
(I22±6 e I19±10)L±Y e OBlower motor operation
signalBlower fan OFF "ON10 to 14 " Below 1.0 V
GND e Body ground
(I19±10 e Body ground)*1O e Body groundGround for main power
supplyConstantContinuity
ACC e GND
(I19±11 e I19±10)P e OPower source (ACC)Turn ignition switch ACC10 to 14 V
TA MSG TAMAbi tt tIG ON, Ambient temp.: 25°C (77°F)1.3 to 1.8 VTAM e SG±TAM
(I19±8 e I19±20)LG±B e Y±BAmbient temperature sen-
sor signalIG ON, Ambient temp.: 40°C
(104°F)0.8 to 1.3 V
BLW e GNDGBOBlower motor operationBl f OFFON10 t 14B l 10VBLW e GND
(I19±4 e I19±10)G±B e OBlower motor o eration
signalBlower fan OFF " ON10 to 14 " Below 1.0 V
RrCLK (I21±15)*1BCommunication signal
Communication circuit
(Built in Fr A/C control panel " Rr
A/C control panel)
±
RrDPD (I21±5)*1RCommunication signal
Communication circuit
(Built in Fr A/C control panel " Rr
A/C control panel)
±
RrSWD (I21±6)*1WCommunication signal
Communication circuit
(Built in Fr A/C control panel " Rr
A/C control panel)
±
RrAMH e GND
(I21±8 e I19±10)*1R±G e ORear air mix control ser-
vomotor operation signalRr temp. control switch: Max.
COOL " Max. HOTBelow 1.0 "
10 to 14 V for 16 sec.
RrAMC e GND
(I21±9 e I19±10)*1L±B e ORear air mix control ser-
vomotor operation signalRr temp. control switch: Max. HOT
" Max. COOLBelow 1.0 "
10 to 14 V for 16 sec.
RrSG e GND
(I21±10 e I19±10)*1L±R e OGround for rear evapora-
tor temperature sensorConstantContinuity
RrS5 e RrSG
(I22±4 e I21±10)*1L±Y e L±RPower supply for rear air
mix control servomotorIG ON4.5 to 5.5 V

Page 2510 of 4323

DI±2308
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2502 Author: Date:
2005 SEQUOIA (RM1146U)Symbols (Terminals No.)
Wiring ColorTerminal DescriptionConditionSpecified Condition
RrTP e RrSG
(I21±18 e I21±10)*1W e L±RRear air mix damper posi-
tion sensor signalRr temp. control switch: Max.
COOL " Max. HOT4.0 to 1.0 V
AC1 e GND
(I22±4 e I19±10)G ± B e OCompressor operation
signalIG ON, A/C switch: OFF " ON3.7 to 4.5 "
1.3 to 2.6 V
RrFACE2 e GND
(I21±11 e I19±10)*1P±B e ORear air outlet control ser-
vomotor operation signalRr A/C control panel switch: except
FACE " FACE10 to 14 "
Below 1.0 V
RrBLK (I21±4)*1LG±BCommunication signal
Communication circuit
(Built in Fr. A/C control panel " Rr.
A/C control panel)
±
RrSTX (I21±14)*1G±YCommunication signal
Communication circuit
(Built in Fr. A/C control panel " Rr.
A/C control panel)
±
RrVM e GND
(I21±7 e I19±10)*1W±G e ORear blower motor control
signalRr blower control switch: LO " MID
" HI7.2 " 4.2 " 0.5 V
RrHR e GND
(I22±7 e I19±10)*1L±O e ORear blower motor opera-
tion signalRr blower control switch: OFF "
LO10 to 14
"Below 1.0 V
RrBLW e GND
(I21±16 e I19±10)*1L e ORear blower motor opera-
tion signalRr blower control switch: OFF "
LOBelow 1.0 "
1.5 to 3.0 V
RrFACE e GND
(I21±2 e I19±10)*1Y±B e ORear air outlet control ser-
vomotor control signalRr A/C control panel FACE switch:
OFF " ON10 to 14 "
Below 1.0 V while
switch is pushed
RrB/L e GND
(I21±3 e I19±10)*1BR±W e ORear air outlet control ser-
vomotor control signalRr A/C control panel B/L switch:
OFF " ON10 to 14 "
Below 1.0 V while
switch is pushed
RrFOOT e GND
(I21±13 e I19±10)*1G±R e ORear air outlet control ser-
vomotor control signalRr A/C control panel FOOT switch:
OFF " ON10 to 14 "
Below 1.0 V while
switch is pushed
RrTE e RrSG LG RLRRear evaporator tempera-Rr evaporator temp.: 0°C (32°F)2.0 to 2.4 VRrTE e RrSG
(I21±17 e I21±10)*1LG±R e L±RRear eva orator tem era
ture sensor signalRr evaporator temp.: 15°C (59°F)2.0 to 2.4 V
RrB/L2 e GND
(I21±12 e I19±10)*1P±G e ORear air outlet control ser-
vomotor control signalRr A/C control panel switch: except
B/L " B/L10 to 14 "
Below 1.0 V
FOOT eGND
(I21±17 e I19±10)Y±B e OAir outlet control servo-
motor control signalMode control switch except: FOOT
" FOOT10 to 14 " Below 1.0 V
FDEF e GND
(I20±7 e I19±10)LG±R e OAir outlet control servo-
motor control signalMode control switch except: FOOT/
DEF "FOOT/DEF10 to 14 " Below 1.0 V
DEF e GND
(I20±18 e I19±10)B±W e OAir outlet control servo-
motor control signalMode control switch except: DEF "
DEF10 to 14 " Below 1.0 V
AMH e GNDRLOAir mix control servomotorIG ON, Set temp.: Max. CoolBelow 1.0 VAMH e GND
(I20±10 e I19±10)R±L e OAir mix control servomotor
operation signalIG ON, Set temp.: Max. Hot10 to 14 V
S5±AM eSG±TP
(I20±22 e I20±12)R±Y e L±RPower supply for air mix
control servomotorIG ON4.5 to 5.5 V
TP e SG±TPGRLRAir mix damper positionIG ON, Set temp.: Max. Cool3.5 to 4.5 VTP e SG TP
(I20±15 e I20±12)G±R e L±RAir mix dam er osition
sensor signalIG ON, Set temp.: Max. Hot0.5 to 1.5 V
AMC e GNDWLOAir mix control servomotorIG ON, Set temp.: Max. Cool10 to 14 VAMC e GND
(I20±9 e I19±10)W±L e OAir mix control servomotor
control signalIG ON, Set temp.: Max. HotBelow 1.0 V
S5±AI e SG±TPI
(I20±11 e I20±13)L±B e Y±RAir inlet control servomo-
tor control signalIG ON4.5 to 5.5 V
TR e SG±TRLWRWRoom temperature sensorIG ON, Cabin temp.: 25°C (77°F)1.8 to 2.2 VTR e SG TR
(I20±3 e I20±1)L±W e R±WRoom tem erature sensor
signalIG ON, Cabin temp.: 40°C (104°F)1.2 to 1.6 V