clock setting VOLKSWAGEN GOLF 1993 1H / 3.G Owners Manual

Page 59 of 156

Downloaded from www.Manualslib.com manuals search engine CONTROLS AND EQUIPMENT

Air vents
Jepending on th e position of rotary regula­
c o r B heated or unheated fresh air flows 'rom all vents.
- h e vents 3 and 4
can be opene d and closed separately:
nur led w heel upwards or to right ­
a nt opened .
n ur l
ed wheel downwa rds or to left ­
e nt closed .
3 y swinging the comp le te ou
tlet grille of ,e nts 3 and 4 the air flow can be moved
v e rtica lly
N hen the knurl
ed disc in the grille is rotated :0 and fro the air flow direction is altered lat ­
e rally.
The rear footwell vents are supp lied to­
gether With vents 5.
Defrosting windscreen and side
windows
• Rotary switch A to stage 3. • Rotary regulators Band C turned fully to
right.
• Vents 3 closed.
• Additional warm air
can be directed to
the side windows via vents 4.
Demisting windscreen and side
windows
When the w indows steam up due to high air
humidity, e.g. when it is raining , we recom­
mend the follo wing settings:
• Rotary switch A to stage 2 or
3.
• Rotary regulator B, if necessary, clock ­

wise into heating range.

With the "Thermotr
onic"" the value then

set is controlled automatically .

• Rotary regulator C
at ~

• Vents 3 closed.

• Additional warm air can be directed to

the side windows via vents 4.

Heating interior quickly
(without "Thermotronic" *)
• Rotary switch A to stage 3. • Rotary regulator B full y to right.
• Rotary regulator C
at tIl
• Vents 3 closed .
• Vents 4 fully or partially opened w ith
knurled discs
as required.
57

Page 60 of 156

Downloaded from www.Manualslib.com manuals search engine Heating interior comfortably
(without "Thermotronic" * )
W hen the windows are clear and the de­
sired temperature has been reached we recommend the following settings

Rotary switch A at stage 1 or 2.
• Rota ry regulator B at the desired heat
o ut put.
• Depending on
air dist ribution
desired, turn rotary regu lator C
be tween
and
If the wind screen mists over again, the reg ulator can also be turne d
be tween
and
• Vent s 3 c losed .
• With vents 4 the des ired amount of war m air and the air flow direction can be
set.
Heating interior as quickly as
possible and comfortably
(with "Thermotronic " *)
When the windows are clea r, th e following
setting is recommended :
• Rotary switch A to s tage
2. • Rotar y reg ulator B to desired va lue on
scale. Approx.: 22 . tIj
• Upper lever to . . . ....
The system works most efficient ly in thi s
position, .
• Close vents 3 .
• With vents 4 the desired amount of
warm
air and the air flow direct ion can be set.
Ventilation (fresh air operation)
With the following settings, unheated fresh
air flows from vents 3 and 4:
• Rota ry
swit ch A to des ir ed stage.
• Rota ry regulator B anti- clockwise to the
stop
PW!l
• Upper lever to . . ~
• Ve nts 3 and 4 open.
If required, regulator C can be turned to
ano ther posit io n .
General notes
• To ensure that the heating and ventila­
tion can work properly, the air inlet in fron t
o f the winds creen should be kept free of ice, snow a n d leaves .
• The heat output depen s on
the coo la nt
tem perat ure -the ful l h eat outp ut is there­fore available when the engin e is warm.
• The stale air escape s th rough openings
in the luggage compartment side panels .
Therefore when loading th e lu gg age com­partment ensure tha t the ope 11ngs a re not cove re d .
• A
ll contr ols exce pt the rota ry switch A
b lower speeds 1-4 can be set to any inte r­
mediate position.

To pr ev ent the windo ws fro m mis tin g up the blower should be runn ing slowly w hen driving at low sp ee ds




58

Page 62 of 156

Downloaded from www.Manualslib.com manuals search engine • •
CONTROLS AND EQUIPMEN.-=T-""------__________________

Air recirculation should only be se­lected for short periods of time as no fresh air is taken in in this mode and the windows can steam up if the air conditioner is switched off.
Note
Buttons D and E can be pressed In conjunc­
tion w ith one another .
Air vents
Depending on the position of rotary regula­
tor B heated or unhea ted fresh air or coo led
air flows from all vents.
The vents 3 and 4 can be opened and closed
separately :

Knurled wheel upwards
or to right ­
vent opened .

Knurled
wheel downwards or to left ­
ven t closed.
By swinging the complete outlet grille of
vents 3 and 4 the air flow ca n be moved
vertically.
W hen the knurled disc in the grille is rota ted
to and fro the air flow direction is altered lat­
erally
The
rear footwell vents are supplied to­
gether with vents 5.
Defrosting windscreen and side
windows
• Rotary switch A to stage 3.
• Rotary regu lators Band C turn ed fully to
right.
• Vents 3 closed .
• Additional warm a
ir can be directed to
the side windows via vents 4.
Demisting windscreen and side
windows ••When the windows steam up due to high air
humidity, e.g. when it is rain ing, we recom­•mend the following settings
• Rotary switch A to stag e 2 or
3. • Rotary regulator B, if necessary, clock­
wise into heating range. ~
• Rotary regu lator C to . JJ~
• Press button D
• Ve nts 3 closed.
• Additiona l warm air can be directed to
th e sid e windows via vents 4.
60

Page 63 of 156

Downloaded from www.Manualslib.com manuals search engine __C_ONTROLS AND EQUIPMENT

Heating interior quickly
• Rotary switch A to stage 3.
• Rotary regulator B fully to right. PWll
• Rotary regulator C
to .. ~
• Vents 3 closed .
• Vents 4 fully or partially opened w ith
1 u rled discs
as required
Heating interior comfortably
hen the w indows are clear and the de­
s red tempera ture has been reached we rec ommend the following settings
Rotary
switch A at stage 1 or 2.
• Rotary regulator B at the desired heat
Jt put.
Depending on air distribution
esir ed , turn rotary regulator C
re ween .. .. ~
'ld ~
, the windscreen mists over again,

e regulator can also be turned

etw een

Vents 3 closed.

With vents 4 the desired amount of
warm air and the air flow direction can be
set.
Ventilation (fresh air operation)
With the following settings, unheated fresh
air flows from vents 3 and 4:
• Switch air conditioner off with button D
• Rotary switch A to desired stage.
• Rotary regulator B anti-clockwise to the
stop D.1
• Rotary regulator C to . .. ~
• Vents 3 and 4 open.

If required, regulator C can be turned to

another position.

Maximum cooling
• All windows and sliding/tilting roof*
closed.

• Rotary s
witch A to stage 4.
• Rotary regulator B to left.

• Rotary regulator C to

• Right-hand button 0 (max) pressed.

• Select air recirculation by pressing but­

ton E

• Vents 3 and 4 open.

In this mod e, air is drawn from inside the ve­

hicle and cooled (air recircu lation) The air
recirculation mode should not be se­lected for long periods of time as no fresh air is then supplied.
Note
Smoking should be avoided w hen air recir­
culation is selected , as the smoke drawn in from the vehicle interior deposits on the
evaporator of the air conditioner. This leads
to permanent odours when the air condi­
tioner is i n operation. These can only be
eliminated by exchanging the evaporator,
which is time-consuming and expensive.
Normal cooling
• Switch air condit ioner on by pressing
button 0
• Rotary
switch A to stage 1 -4 as re­
quired.
• Rotary regula
tor B to the desired air tem­perature (so that heating is also possible)
• Rotary regulator C to desired position
• Vents 3 and 4 set
as required.
I n this operating mode air is drawn in from
outside and cooled (fresh air operation)
To operate the Climatronic*, see pages 62 and 63.
61