wiring diagram AUDI A4 1995 B5 / 1.G AWM Engine Motronic Injection System Servicing Workshop Manual

AUDI A4 1995 B5 / 1.G AWM Engine Motronic Injection System Servicing Workshop Manual A4 1995 B5 / 1.G AUDI AUDI https://www.carmanualsonline.info/img/6/1091/w960_1091-0.png AUDI A4 1995 B5 / 1.G AWM Engine Motronic Injection System Servicing Workshop Manual

Page 42 of 79

AUDI A4 1995 B5 / 1.G AWM Engine Motronic Injection System Servicing Workshop Manual 24-39
      
Checking voltage supply  
     
Test requirements:  
     
Fuse for fuel injectors OK 
     
       Electrical Wiring Diagrams, Troubleshooting & 
Component Locations   
     
Fuel Pump (

Page 43 of 79

AUDI A4 1995 B5 / 1.G AWM Engine Motronic Injection System Servicing Workshop Manual  Electrical Wiring Diagrams, Troubleshooting & Component Locations    -  Check wire connection between terminal 1 and fuse for injector valves 
for open circuit: 
Pa
ge 43 of 79 Motronic in
jection s

Page 63 of 79

AUDI A4 1995 B5 / 1.G AWM Engine Motronic Injection System Servicing Workshop Manual 24-56
 
    
If specified value is not obtained:  
 Electrical Wiring Diagrams, Troubleshooting & Component Locations   
If specified value is obtained:  -  Connect multimeter for voltage measurement

Page 66 of 79

AUDI A4 1995 B5 / 1.G AWM Engine Motronic Injection System Servicing Workshop Manual 24-58
       If specified values are not obtained:  
     
-  Repeat test at another terminal of fuse socket.
      If specified values are not obtained again:  
     
-  Check wire connections.

Page 72 of 79

AUDI A4 1995 B5 / 1.G AWM Engine Motronic Injection System Servicing Workshop Manual 24-64
      
Voltage supply for Mass Air Flow (MAF) 
sensor, checking  
     
Test requirements:  
     
Fuse for Mass Air Flow (MAF) sensor OK 
     
       Electrical Wiring Diagrams, Troubleshootin

Page 74 of 79

AUDI A4 1995 B5 / 1.G AWM Engine Motronic Injection System Servicing Workshop Manual 24-65
       If specified value is not obtained:  
     
-  Check wire connection from terminal 2 of 
connector to Fuel Pump (FP) relay via fuse for 
open circuit and short circuit to Ground (GND):