lock AUDI A4 1995 B5 / 1.G Instrument Cluster OBD From Model Year 2000 User Guide
[x] Cancel search | Manufacturer: AUDI, Model Year: 1995, Model line: A4, Model: AUDI A4 1995 B5 / 1.GPages: 99, PDF Size: 0.27 MB
Page 43 of 99

01-114
Read Measuring Value Block (scan tool
function 08)
Initiating "Read Measuring Value Block"
Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -0- and -8-. This selects "Read measuring value block",
function 08.
- Press -Q- button to confirm input.
Rapid data transfer
Q
08 - Measured value block
Indicated on display
- Press -Q- button to confirm input.
Read measured value block Input displa
y group number XXX
Indicated on display:
The selected measuring value block is now displayed in standard form. - Enter display group number (from table Page 01
-115
) and press -Q-
button to confirm input.
Pa
ge 43 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2
Page 50 of 99

01-118
Notes:
For an instrument cluster replacement, data
from display groups 10...15 must be printed out.
Measuring value blocks 125 and 126 indicate
the participants in the powertrain data-BUS.
Measuring value block 130 indicates the
participants in the comfort system databus.
Measuring value block 140 indicates the
participants in the information data-BUS
Display will always indicate the actual values
obtained from the sensors. The values which
appear on the instrument cluster are filtered
and may be different.
If the actual engine coolant temperature is
between 80 C and 100 C, instrument cluster
will always show 90 C.
Pa
ge 50 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2
Page 51 of 99

01-119
Measuring value block 001
Read Measuring Value Block 1
Indicated on display:
30 MPH 2400 RPM Oil p2
Time
Oil pressure switch 2
Oil p2 < min. Oil p2 OK
Engine speed (RPM)
0 - 9990 RPM
Speed
0 - 187 MPH
Pa
ge 51 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2
Page 52 of 99

01-120
Measuring value block 2
Read Measuring Value Block 2
Indicated on display:
6256 mi 43 l 82 Ohm
23.0 C
Outside air temperature
-40 to +70 C
Tank sensor
approx. 280 Ohm (empty) ... approx. 40 Ohm (full)
Fuel gauge
0 - 100 1
Display value of trip odometer
Pa
ge 52 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2
Page 53 of 99

01-121
Measuring value block 3
Read Measuring Value Block 3
Indicated on display:
85.0 C
Coolant temperature
50 - 130 C
Pa
ge 53 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2
Page 54 of 99

01-122
Measuring value block 10
Read Measuring Value Block 10
Indicated on display:
Channel 30 128 Channel 9 626 mi
Input value for adaptation of odometer
Adaptation channel for odometer
Factory adjusted adaptation value
Adaptation channel of fuel gauge sender resistance range
Note:
If the value "128" in display field 2 was changed due to a customer complaint, the changed value must be transferred when
replacing instrument cluster.
Pa
ge 54 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2
Page 55 of 99

01-123
Measuring value block 11
Read Measuring Value Block 11
Indicated on display:
Channel 4 2 Channel 3 100
Factory adjusted adaptation value
Adaptation channel of fuel gauge
Selected language
1 is German
2 is English
Adaptation channel for language version of driver information display
Note:
If the value "100" in display field 4 was changed due to a customer complaint, the changed value must be transferred when
replacing instrument cluster.
Pa
ge 55 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2
Page 56 of 99

01-124
Measuring value block 12
Read Measuring Value Block 12
Indicated on display:
Channel 40 8 Channel 41 10
Time expired
For example, 10 means 10 days
Adaptation channel for time since service
Driven miles
8 means 800 miles
Adaptation channel for distance driven since service
Pa
ge 56 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2
Page 57 of 99

01-125
Measuring value block 13
Read Measuring Value Block 13
Indicated on display:
Channel 42 8 Channel 43 8
Maximum mileage
8 means 8000 miles
1)
Adaptation channel for maximum mileage
Minimum mileage performance
2)
8 means 8000 miles
1)
Adaptation channel for minimum mileage
Note:
1) The currently valid specifications can be found in the "Maintenance" book.
Repair Manual, Maintenance
2) For USA-vehicles: For instrument cluster of the manufacturer Marelli, the starting value (first value of remaining distance
without calculating) is set to 8000 miles. For instrument clusters of the manufacturer VDO, the starting value is set to 8100
miles. The 100 miles which are displayed in excess, are compensated during driving. For vehicles with 1.8 Liter Turbo engine,
the starting value of 5000 is set. For both manufacturers 8000 or 8100 miles is displayed anyway. The damper action also
occurs from the actual remaining interval during driving operation.
Pa
ge 57 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2
Page 58 of 99

01-126
Measuring value block 14
Read Measuring Value Block 14
Indicated on display:
Channel 44 365
Maximum time interval
365 means 365 days/1 year
1)
Adaptation channel for maximum time interval
Note:
1) The currently valid specifications can be found in the "Maintenance" book.
Repair Manual, Maintenance
Pa
ge 58 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2