sensor AUDI A4 1997 B5 / 1.G ATQ Engine Readiness Code User Guide
[x] Cancel search | Manufacturer: AUDI, Model Year: 1997, Model line: A4, Model: AUDI A4 1997 B5 / 1.GPages: 47, PDF Size: 0.14 MB
Page 26 of 47

01-96
Work step 8: Diagnostic of oxygen sensor
control system
Test requirement
Engine continues to run at 2200 RPM.
Basic Settin
g
Q
Input display group number XXX
When indicated on display:
- Press buttons -0-, -3- and -7- to select "display group number 037" and
press -Q- button to confirm input.
System in Basic Setting 37
1
2
3
4
When indicated on display:
- Check specified value in display field 4.
Pa
ge 26 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7
Page 27 of 47

01-97
Display fields
1 2 3 4
Display group 037: Diagnostic of oxygen sensor control system (Bank 1)
Display xxx % x.xxx volts xxx ms
---
Indicated Load Voltage of oxygen sensors
behind catalytic converter,
bank 1 Oxygen sensor
correction value
between sensor 1
and sensor 2 (bank
1) Diagnostic condition
Functional
range 12 to
100 % 0.100 to 1.000 V -800 to 800 ms
Test OFF
Test ON
System OK
System not OK
Specified
value 12 to 26
% 0.100 to 1.000 V -800 to 800 ms System OK
Notes
If "System not OK" is displayed: Check
Diagnostic Trouble Code (DTC) memory
Page 01
-15
If specified value "Syst. OK" is obtained:
- Press -C- button. Basic Settin
g
Q
When indicated on display:
Pa
ge 27 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7
Page 29 of 47

01-98
If specified value "Syst. OK" is obtained:
System in Basic Setting 34
1
2
3
4
When indicated on display:
- Check specified value in display field 4.
Display fields
1 2 3 4
Display group 038: Diagnostic of oxygen sensor control system (Bank 2)
Display xxx % x.xxx volts xxx ms
---
Indicated Load Voltage of oxygen sensors
behind catalytic converter,
bank 2 Oxygen sensor
correction value
between sensor 2
and sensor 2 (bank
1) Diagnostic condition
Functional
range 12 to
100 % 0.100 to 1.000 V -800 to 800 ms
Test OFF
Test ON
System OK
System not OK
Specified
value 12 to 26
% 0.100 to 1.000 V -800 to 800 ms System OK
Notes
If "System not OK" is displayed: Check
Diagnostic Trouble Code (DTC) memory
Page 01
-15
- Press -C- button.
Pa
ge 29 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7
Page 30 of 47

01-99
Work step 9: Diagnostic of oxygen sensor
aging behind catalytic converter
Test requirement
Engine continues to run at 2200 RPM.
Basic Settin
g
Q
Input display group number XXX
When indicated on display:
- Press buttons -0-, -4- and -3- to select "display group number 043" and
press -Q- button to confirm input.
System in Basic Setting 43
1
2
3
4
When indicated on display:
- Check specified value in display field 4.
Pa
ge 30 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7
Page 31 of 47

01-100
Display fields
1 2 3 4
Display group 043: Oxygen sensor aging diagnostic, oxygen sensor behind catalytic converter (bank 1)
Display xxxx/min
xxx C
x.x s
---
Indicated Engine speed
(RPM) Exhaust
temperature Voltage of oxygen sensors
behind catalytic converter,
bank 1 Diagnostic condition
Functional
range 630 to 6800
RPM 70 to 850 C
0.100 to 1.000 V Test OFF
Test ON
B1-S2 OK
B1-S2 not OK
Specified
value 2200 RPM
above 380 C 0.100 to 1.000 V B1-S2 OK
Notes
If "B1-S2 not OK" is displayed: Check
Diagnostic Trouble Code (DTC) memory
Page 01
-15
If specified value "B1-S1 OK" is obtained:
- Press -C- button. Basic Settin
g
Q
Input displa
y group number XXX
When indicated on display:
-
Press buttons -0-, -4- and -4- to select "display group number 044"
Pa
ge 31 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7
Page 33 of 47

01-101
If specified value B2-S2 OK" is obtained:
System in Basic Setting 44
1
2
3
4
When indicated on display:
- Check specified value in display field 4.
Display fields
1 2 3 4
Display group 044: Oxygen sensor aging diagnostic, oxygen sensor behind catalytic converter (bank 2)
Display xxxx/min
xxx C
x.x s
---
Indicated Engine speed
(RPM) Exhaust
temperature Voltage of oxygen sensors
behind catalytic converter,
bank 2 Diagnostic condition
Functional
range 630 to 6800
RPM 70 to 850 C
0.100 to 1.000 V Test OFF
Test ON
B2-S2 OK
B2-S2 not OK
Specified
value 2200 RPM
above 380 C 0.100 to 1.000 V B2-S2 OK
Notes
If "B2-S2 not OK" is displayed: Check
Diagnostic Trouble Code (DTC) memory
Page 01
-15
- Press -C- button.
Pa
ge 33 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7
Page 40 of 47

01-107
Display fields
1 2 3 4
Display group 070: Diagnostic of tank ventilation valve
Display xx % xx.x % g/s
---
Indicated Degree tank
ventilation valve is
opened Oxygen
sensor
control
deviation Deviation
of
Idle
control Diagnostic condition
Functional
range 0 to 99 % -25.0 to 25.0
%
Test OFF
Test ON
TVV OK
TVV not OK
Aborted
Specified
value 0 to 99 % -7.0 to 7.0
% x.xx g/s
1) TVV OK
Notes
If "TVV not OK" is displayed: Check Diagnostic Trouble
Code (DTC) memory Page 01
-15
. Check Evaporative
Emission (EVAP) canister purge regulator valve -N80-
Page 24
-128
1) An indication is only displayed if diagnostic result falls within a specified range due to deviation of idle control and not due to
deviation of an oxygen sensor (e.g. sensor 1 from EVAP canister). Otherwise, display field 3 remains empty.
If specified value "TVV OK" is obtained:
Pa
ge 40 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7