01-33
DTC
Description of malfunction
Corrective action
SAE
VAG
P1102 17510 O2 Sensor Heating Circ., Bank1-
Sensor1
Short to B+
2) - Check oxygen sensor heater Page 24
-114
P1105 17513 O2 Sensor Heating Circ., Bank1-
Sensor2
Short to B+
2)
P1107 17515 O2 Sensor Heating Circ., Bank2-
Sensor1
Short to B+ 2)
P1110 17518 O2 Sensor Heating Circ., Bank2-
Sensor2
Short to B+ 2)
P1111 17519 O2 Control (Bank 1)
System too lean - Check oxygen sensor adaptation values and oxygen sensor control
Page 24
-86
P1112 17520 O2 Bank 1
System too rich
2) With this malfunction the exhaust Malfunction Indicator Light (MIL) is only switched on by the ECM, if the malfunction is
recognized after the engine has been restarted. Significance of MIL Page 01
-3 .
Pa
ge 40 of 166 Motronic s
ystem, On Board Dia
gnostic
(OBD
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.01.1
Page 142 of 166

01-118
Display fields
1 2 3 4
Display group 041: Oxygen sensor heater, bank 1
Display
xxx kOhm
Heater before before CAT
ON xxx kOhm
Heater before behind CAT
ON
Indicated
Bank 1, Sensor 1
Condition of heater
Bank 1, Sensor 2
Condition of heater
Work range
Heater b. CAT ON
Heater b. TWC OFF
Heater a. CAT ON
Heater a. CAT OFF
Specified
value 0 - 0.5 kOhm
Heater b. CAT ON/OFF
0 - 0.9 kOhm
Heater a. CAT ON/OFF Important note for display fields 1,2,3 and 4:
Display fields 1 and 3 will not indicate any value if the operating temperature of the oxygen sensors is not reached, that
means both fields are empty. (Increase Engine Speed to reach specified value).
After the operating temperature is reached, the display fields 1 and 3 must display a value of less than 0.5K Ohm
Only proceed with test after value of less than 0.5K Ohm is displayed with in display fields 1 and 3.
The Engine Control Module (ECM) cycles at certain operating conditions the oxygen sensor heating, that means, the
heater is certain operating conditions ON or OFF. It is therefore possible that the specification in display field 2 and 4
appears periodically as "Heater b. CAT OFF" or "Heater a. CAT OFF"
Pa
ge 142 of 166 Motronic s
ystem, On Board Dia
gnostic
(OBD
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.01.1
Page 145 of 166

The Engine Control Module (ECM) cycles at certain operating conditions the oxygen sensor heating, that means, the
heater is certain operating conditions ON or OFF. It is therefore possible that the specification in display field 2 and 4
appears periodically as "Heater b. CAT OFF" or "Heater a. CAT OFF"
- Press -C- button.
Pa
ge 145 of 166 Motronic s
ystem, On Board Dia
gnostic
(OBD
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.01.1