Test requirements: 
     
Exhaust system free of leaks. 
     Coolant Temperature at least 80 C. 
     
Test sequence  
     
-  Connect VAS5051 tester or VAG1551 scan tool 
and select control module for engine electronics 
using "address word" 01   Page 01
-10
 . Engine 
must run at idle. 
Rapid data transfer 
HELP
Select function XX
    
When indicated on display  
-  Press buttons -0- and -4- to select "Initiate basic setting" and press -Q- 
button to confirm input. 
Basic Settin
g 
Q
Enter displa
y group number XXX
    
When indicated on display  
Note:  -  Press buttons -0-, -3- and -0- to select "display group number 030" and 
press -Q- button to confirm input. 
-  Check specified value in display field 1.
Increase engine speed to obtain specified values faster. "Oxygen sensor status" indicates status of oxygen sensor control and 
oxygen sensors. 
Pa
ge 2 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2 
Page 4 of 37

24-74
      
-  Do not start test until indication in display field 1 
has reached "111" at least once. 
     
Checking oxygen sensor adaptation values 
and control  
     
- Press -C- button.Basic Settin
g 
Q
Enter displa
y group number XXX
    
When indicated on display  
-  Press buttons -0-, -3- and -2- to select "display group number 032" and 
press -Q- button to confirm input. 
System in basic setting 32  
1 
2 
3 
4
    
When indicated on display  
-  Check oxygen sensor values in display fields 1 and 2:
Pa
ge 4 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2 
Page 5 of 37

24-75
 
  
Display fields  
  
1   2   3   4  
Display group 036: Oxygen sensor adaptation values  
Display  
xx.x %  
xx.x %  
  
  
Indicated  
Oxygen sensor adaptation value Bank 1, 
sensor 1at idle (additive)  Oxygen sensor adaptation value Bank 1, sensor 
1at partial throttle(multiple)      
Specified 
value  -10.0 to 10.0 %  
can fluctuate slightly  -10.0 to 10.0 %  
can fluctuate slightly    
    
  
Note  
If specified value is not obtained   Page 24
-78
   
  
  
     
- Press -C- button.Basic Settin
g 
Q
Enter display group number XXX
    
When indicated on display  
-  Press buttons -0-, -3- and -3- to select "display group number 033" and 
press -Q- button to confirm input. 
System in basic setting 33  
1 
2 
3 
4
    
When indicated on display  
-  Check oxygen sensor control in display fields 1 and 2.
Pa
ge 5 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2 
Page 14 of 37

24-84
      
Test sequence  
     
-  Connect VAS5051 tester or VAG1551 scan tool 
and select control module for engine electronics 
using "address word" 01   Page 01
-10
 . Engine 
must run at idle. 
Rapid data transfer 
HELP
Select function XX
    
When indicated on display  
-  Press buttons -0- and -4- to select "Initiate basic setting" and press -Q- 
button to confirm input. 
Basic Settin
g 
Q
Enter displa
y group number XXX
    
When indicated on display  
-  Press buttons -0-, -3- and -4- to select "display group number 034" and 
press -Q- button to confirm input. 
System in basic setting 34  
1 
2 
3 
4
    
When indicated on display  
Note:  
This process can take a few minutes.  -  Use VAG1788/10 RPM adjuster to adjust engine speed to between 
1800 and 2200 RPM. 
-  Check specified value in display field 4:
Pa
ge 14 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2 
Page 19 of 37

24-89
      
Test requirements: 
     
Road test performed and DTC memory 
erased. 
     Coolant Temperature at least 80 C. 
     
Test sequence  
     
-  Connect VAS5051 tester or VAG1551 scan tool 
and select control module for engine electronics 
using "address word" 01   Page 01
-10
 . Engine 
must run at idle. 
Rapid data transfer 
HELP
Select function XX
    
When indicated on display  
Note:  
During basic setting, the Evaporative Emission (EVAP) canister purge 
regulator valve (EVAP valve -N80-) is closed and the A/C compressor is 
switched off  -  Press buttons -0- and -4- to select "Initiate basic setting" and press -Q- 
button to confirm input. 
Basic Settin
g 
Q
Enter displa
y group number XXX
    
When indicated on display  
-  Press buttons -0-, -3- and -4- to select "display group number 034" and 
press -Q- button to confirm input. 
Pa
ge 19 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2 
Page 20 of 37

24-90
 
System in basic setting 34  
1 
2 
3 
4
    
When indicated on display  
Note:  
This process can take a few minutes.  -  Use VAG1788/10 RPM adjuster to adjust engine speed to between 
2800 and 3200 RPM. 
-  Continue test as soon as display field 2 indicates an exhaust 
temperature of more than 350 C. - Press -C- button.
-  Use VAG1788/10 RPM adjuster to adjust engine speed to between 
1800 and 2200 RPM. 
Basic Setting 
Q
Enter displa
y group number XXX
    
When indicated on display  
-  Press buttons -0-, -3- and -0- to select "display group number 030" and 
press -Q- button to confirm input. 
System in basic setting 30  
1 
2 
3 
4 
    
When indicated on display  
Note:  
"Oxygen sensor status" indicates status of oxygen sensor control and 
oxygen sensor.  -  Check oxygen sensor status for oxygen sensor behind catalytic 
converter in display field 2. 
Pa
ge 20 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2 
Page 22 of 37

24-92
      
Checking oxygen sensor control behind 
catalytic converter  
     
- Press -C- button.Basic Setting 
Q
Enter displa
y group number XXX
    
When indicated on display  
-  Press buttons -0-, -3- and -7- to select "display group number 037" and 
press -Q- button to confirm input. 
System in basic setting 37  
1 
2 
3 
4
    
When indicated on display  
-  Check oxygen sensor voltage in display field 2.
-  Check dwell time of oxygen sensor control before catalytic converter in 
display field 3 and diagnostic result in display field 4. 
Pa
ge 22 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2