heater AUDI A4 2000 B5 / 1.G APB Engine Motronic Syst
[x] Cancel search | Manufacturer: AUDI, Model Year: 2000, Model line: A4, Model: AUDI A4 2000 B5 / 1.GPages: 166, PDF Size: 0.53 MB
Page 141 of 166

01-117
       If specified value in display "System OK" is 
reached:  
     
- Press -C- button.
     
Work step 7: Diagnosis of oxygen sensor 
heater  System in Basic Setting 
Q
Input displa
y group number XXX
    
When indicated on display  
-  Press buttons -0-, -4- and -1- to select display group number 041 and 
confirm with -Q- button. 
System in Basic Setting 41  
1 
2 
3 
4
    
When indicated on display  
Note:  
Increasing engine speed accelerates the obtaining of specified values.  -  Check specified value in display field 1 and 3:
Pa
ge 141 of 166 Motronic s
ystem, On Board Dia
gnostic 
(OBD
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.01.1 
Page 142 of 166

01-118
 
  
Display fields  
  
1   2   3   4  
Display group 041: Oxygen sensor heater, bank 1  
Display  
xxx kOhm  
Heater before before CAT 
ON  xxx kOhm  
Heater before behind CAT 
ON  
Indicated  
Bank 1, Sensor 1 
  Condition of heater  
Bank 1, Sensor 2 
  Condition of heater  
Work range    
Heater b. CAT ON  
Heater b. TWC OFF    
Heater a. CAT ON  
Heater a. CAT OFF  
Specified 
value  0 - 0.5 kOhm  
Heater b. CAT ON/OFF  
0 - 0.9 kOhm  
Heater a. CAT ON/OFF  Important note for display fields 1,2,3 and 4:  
 
Display fields 1 and 3 will not indicate any value if the operating temperature of the oxygen sensors is not reached, that 
means both fields are empty. (Increase Engine Speed to reach specified value). 
 After the operating temperature is reached, the display fields 1 and 3 must display a value of less than 0.5K Ohm
 Only proceed with test after value of less than 0.5K Ohm is displayed with in display fields 1 and 3.
 The Engine Control Module (ECM) cycles at certain operating conditions the oxygen sensor heating, that means, the 
heater is certain operating conditions ON or OFF. It is therefore possible that the specification in display field 2 and 4 
appears periodically as "Heater b. CAT OFF" or "Heater a. CAT OFF" 
Pa
ge 142 of 166 Motronic s
ystem, On Board Dia
gnostic 
(OBD
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.01.1 
Page 144 of 166

01-119
 
  
Display fields  
  
1   2   3   4  
Display group 042: Oxygen sensor heater, bank 1  
Display  
xxx kOhm  
Heater before before CAT 
ON  xxx kOhm  
Heater before behind CAT 
ON  
Indicated  
Bank 1, Sensor 1   
Condition of heater  
Bank 1, Sensor 2 
  Condition of heater  
Work range    
Heater b. CAT ON  
Heater b. TWC OFF    
Heater a. CAT ON  
Heater a. CAT OFF  
Specified 
value  0 - 0.5 kOhm  
Heater b. CAT ON/OFF  
0 - 0.9 kOhm  
Heater a. CAT ON/OFF  
Note  
Observe note 
below    
Observe note   
below    Important note for display fields 1,2,3 and 4:  
 
Display fields 1 and 3 will not indicate any value if the operating temperature of the oxygen sensors is not reached, that 
means both fields are empty. (Increase Engine Speed to reach specified value). 
 After the operating temperature is reached, the display fields 1 and 3 must display a value of less than 0.5K Ohm
 Only proceed with test after value of less than 0.5K Ohm is displayed with in display fields 1 and 3.
Pa
ge 144 of 166 Motronic s
ystem, On Board Dia
gnostic 
(OBD
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.01.1 
Page 145 of 166

 The Engine Control Module (ECM) cycles at certain operating conditions the oxygen sensor heating, that means, the 
heater is certain operating conditions ON or OFF. It is therefore possible that the specification in display field 2 and 4 
appears periodically as "Heater b. CAT OFF" or "Heater a. CAT OFF" 
     
- Press -C- button.
Pa
ge 145 of 166 Motronic s
ystem, On Board Dia
gnostic 
(OBD
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.01.1