transmission wiring diagram AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide A6 2000 C5 / 2.G AUDI AUDI https://www.carmanualsonline.info/img/6/1218/w960_1218-0.png AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide

Page 28 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide 01-291
 
Resistance measurement: switch multimeter to 20 K   measuring range  
Test step  
VAG  
1598/20  
sockets  Test of  
Test 
conditions 
- Additional 
steps Specified  
value  Corrective action

Page 32 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide 01-293
 
Resistance measurement: switch multimeter to 2 M   measuring range  
Test 
step  VAG  
1598/20  
sockets  Test of  
Test conditions 
- Additional stepsSpecified  
value  Corrective action  
2

Page 35 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide 2) Corresponding terminals at Engine Control Module (ECM).  
     
 Electrical Wiring Diagrams & Component Locations   A) Signal is transmitted to Transmission Control Module (TCM) via the Engine Cont

Page 37 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide      
 Electrical Wiring Diagrams & Component Locations binder   A) Signal is transmitted to Transmission Control Module (TCM) via the Engine Control Module (ECM). Test is only for vehicles 
without C

Page 38 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide 01-296
 
Resistance measurement: switch multimeter to 2 M   measuring range  
Test 
step  VAG  
1598/20  
sockets  Test of  
Test conditions 
- Additional steps Specified  
value  Corrective action

Page 40 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide 01-297
 
Voltage measurement: switch multimeter to 20 V measuring range  
Test 
step  VAG  
1598/20sockets  Test of  
Test conditions 
- Additional stepsSpecified  
value  Corrective action  
26   13

Page 41 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide 01-298
 
Voltage measurement: switch multimeter to 20 V measuring range  
Test step  
VAG  
1598/20sockets  Test of  
Test conditions 
- Additional stepsSpecified  
value  Corrective action  
27  
46

Page 43 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide 01-299
 
Voltage measurement: switch multimeter to 20 V measuring range  
Test step  
VAG1598/20sockets  
Test of  
Test conditions 
- Additional stepsSpecified  
value  Corrective action  
27  
cont

Page 52 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide 01-305
 
Terminal on  
16-pin connector  Socket on VAG1598/20  
adapter  Specification  
Corrective action  
14   21  
 1.5    
- Repair open circuit according to current wiring diagram.
- Check conne

Page 61 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing User Guide 01-312
      
-  If the specified value is not read, check fuses 
and wiring connectors according to wiring 
diagram and make necessary repairs. 
     
Note:  
     If the check results and the voltag
Page:   < prev 1-10 11-20 21-30 next >