wiring diagram AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual A6 2000 C5 / 2.G AUDI AUDI https://www.carmanualsonline.info/img/6/1218/w960_1218-0.png AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual

Page 2 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-274
      
Additional information  
     
Repair Manual, 5 Spd. Automatic Transmission 
01V, 
     Electrical Wiring Diagrams, Troubleshooting & 
Component Locations" 
     
Notes:  
     Use VAG15

Page 4 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-275
      
The contact numbers of the connector and the 
socket numbers of VAG 1598/20 test box match 
up  page 01
-277
 . 
     
To check the multi-function switch, it is not 
necessary to connect

Page 5 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual the instrument cluster. 
     Ground (GND) connections OK: 
     
   Check battery Ground (GND) strap and Ground 
(GND) strap between body and transmission. 
     
   Check Ground (GND) connections fo

Page 7 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-277
 88-pin connector for Transmission Control Module (TCM) -J217- (sockets on VAG1598/20)  
1-   Solenoid valve 5 -N92-   18-
  Kick-down switch -F8- (not for E-gas and V6-TDI)  
2-   Shift lock s

Page 14 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-282
 Electrical test table
 
Voltage measurement: Switch multimeter to 20 V measuring range  
Test 
step  VAG  
1598/20  
sockets  Test of  
Test 
conditions 
- Additional 
steps Specified  
value

Page 16 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-283
 
Voltage measurement: switch multimeter to 20 V measuring range  
Test step  
VAG  
1598/20  
sockets  Test of  
Test conditions 
- Additional stepsSpecified  
value  Corrective action  
3 
1)

Page 18 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-284
 
Voltage measurement: switch multimeter to 20 V measuring range  
Test step  
VAG  
1598/20  
sockets  Test of  
Test conditions 
- Additional stepsSpecified  
value  Corrective action  
5 
1)

Page 19 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-285
 
Voltage measurement: switch multimeter to 20 V measuring range  
Test 
step  VAG  
1598/20  
sockets  Test of  
Test conditions 
- Additional stepsSpecified  
value  Corrective action  
6

Page 20 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-286
 
Resistance measurement: switch multimeter to 200   measuring range  
Test 
step  VAG  
1598/20  
sockets  Test of  
Test 
conditions 
- Additional 
steps Specified  
value  Corrective action

Page 21 of 66

AUDI A6 2000 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-287
 
Resistance measurement: switch multimeter to 200   measuring range  
Test 
step  VAG  
1598/20  
sockets  Test of  
Test 
conditions 
- Additional stepsSpecified  
value  Corrective action