01-96
      
Work step 8: Diagnostic of oxygen sensor 
control system 
     
Test requirement  
     
Engine continues to run at 2200 RPM. 
Basic Settin
g 
Q
Input display group number XXX
    
When indicated on display:  
-  Press buttons -0-, -3- and -7- to select "display group number 037" and 
press -Q- button to confirm input. 
System in Basic Setting 37  
1 
2 
3 
4
    
When indicated on display:  
-  Check specified value in display field 4.
Pa
ge 26 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 27 of 47

01-97
 
  
Display fields  
  
1   2   3   4  
Display group 037: Diagnostic of oxygen sensor control system (Bank 1)  
Display   xxx %   x.xxx volts   xxx ms  
---  
Indicated   Load   Voltage of oxygen sensors 
behind catalytic converter, 
bank 1  Oxygen sensor 
correction value  
between sensor 1 
and sensor 2 (bank 
1)  Diagnostic condition  
Functional 
range  12 to 
100 %  0.100 to 1.000 V   -800 to 800 ms  
Test OFF  
Test ON  
System OK  
System not OK  
Specified 
value  12 to 26 
%  0.100 to 1.000 V   -800 to 800 ms   System OK  
Notes  
  
  
  
If "System not OK" is displayed: Check 
Diagnostic Trouble Code (DTC) memory 
 Page 01
-15
   
      If specified value "Syst. OK" is obtained:  
     
- Press -C- button. Basic Settin
g 
Q
    
When indicated on display:  
Pa
ge 27 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 29 of 47

01-98
 If specified value "Syst. OK" is obtained:  
System in Basic Setting 34  
1 
2 
3 
4
    
When indicated on display:  
-  Check specified value in display field 4.
  
Display fields  
  
1   2   3   4  
Display group 038: Diagnostic of oxygen sensor control system (Bank 2)  
Display   xxx %   x.xxx volts   xxx ms  
---  
Indicated   Load   Voltage of oxygen sensors 
behind catalytic converter, 
bank 2  Oxygen sensor 
correction value  
between sensor 2 
and sensor 2 (bank 
1)  Diagnostic condition  
Functional 
range  12 to 
100 %  0.100 to 1.000 V   -800 to 800 ms  
Test OFF  
Test ON  
System OK  
System not OK  
Specified 
value  12 to 26 
%  0.100 to 1.000 V   -800 to 800 ms   System OK  
Notes  
  
  
  
If "System not OK" is displayed: Check 
Diagnostic Trouble Code (DTC) memory 
 Page 01
-15
   
- Press -C- button. 
Pa
ge 29 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 30 of 47

01-99
      
Work step 9: Diagnostic of oxygen sensor 
aging behind catalytic converter 
     
Test requirement  
     
Engine continues to run at 2200 RPM. 
Basic Settin
g 
Q
Input display group number XXX
    
When indicated on display:  
-  Press buttons -0-, -4- and -3- to select "display group number 043" and 
press -Q- button to confirm input. 
System in Basic Setting 43  
1 
2 
3 
4
    
When indicated on display:  
-  Check specified value in display field 4.
Pa
ge 30 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 31 of 47

01-100
 
  
Display fields  
  
1   2   3   4  
Display group 043: Oxygen sensor aging diagnostic, oxygen sensor behind catalytic converter (bank 1)  
Display  xxxx/min  
xxx C  
x.x s  
---  
Indicated  Engine speed 
(RPM)  Exhaust 
temperature  Voltage of oxygen sensors 
behind catalytic converter, 
bank 1  Diagnostic condition  
Functional 
range  630 to 6800 
RPM  70 to 850  C  
0.100 to 1.000 V   Test OFF  
Test ON  
B1-S2 OK  
B1-S2 not OK  
Specified 
value  2200 RPM  
above 380  C  0.100 to 1.000 V   B1-S2 OK  
Notes  
  
  
  
If "B1-S2 not OK" is displayed: Check 
Diagnostic Trouble Code (DTC) memory 
 Page 01
-15
   
      If specified value "B1-S1 OK" is obtained:  
     
- Press -C- button. Basic Settin
g 
Q
Input displa
y group number XXX
    
When indicated on display:  
- 
Press buttons -0-, -4- and -4- to select "display group number 044" 
Pa
ge 31 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 33 of 47

01-101
 If specified value B2-S2 OK" is obtained:  
System in Basic Setting 44  
1 
2 
3 
4
    
When indicated on display:  
-  Check specified value in display field 4.
  
Display fields  
  
1   2   3   4  
Display group 044: Oxygen sensor aging diagnostic, oxygen sensor behind catalytic converter (bank 2)  
Display  xxxx/min  
xxx C  
x.x s  
---  
Indicated  Engine speed 
(RPM)  Exhaust 
temperature  Voltage of oxygen sensors 
behind catalytic converter, 
bank 2  Diagnostic condition  
Functional 
range  630 to 6800 
RPM  70 to 850  C  
0.100 to 1.000 V   Test OFF  
Test ON  
B2-S2 OK  
B2-S2 not OK  
Specified 
value  2200 RPM  
above 380  C  0.100 to 1.000 V   B2-S2 OK  
Notes  
  
  
  
If "B2-S2 not OK" is displayed: Check 
Diagnostic Trouble Code (DTC) memory 
 Page 01
-15
   
- Press -C- button. 
Pa
ge 33 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 40 of 47

01-107
 
  
Display fields  
  
1   2   3   4  
Display group 070: Diagnostic of tank ventilation valve  
Display   xx %   xx.x %   g/s  
---  
Indicated  Degree tank 
ventilation valve is 
opened  Oxygen 
sensor 
control 
deviation  Deviation 
of 
Idle 
control  Diagnostic condition  
Functional 
range  0 to 99 %   -25.0 to 25.0 
%    
Test OFF  
Test ON  
TVV OK  
TVV not OK  
Aborted  
Specified 
value  0 to 99 %   -7.0 to 7.0 
%  x.xx g/s 
1)  TVV OK  
Notes  
  
    
If "TVV not OK" is displayed: Check Diagnostic Trouble 
Code (DTC) memory   Page 01
-15
 . Check Evaporative 
Emission (EVAP) canister purge regulator valve -N80-   
Page 24
-128
   
1) An indication is only displayed if diagnostic result falls within a specified range due to deviation of idle control and not due to 
deviation of an oxygen sensor (e.g. sensor 1 from EVAP canister). Otherwise, display field 3 remains empty.  
      If specified value "TVV OK" is obtained:  
Pa
ge 40 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7