wiring AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System A8 2000 D2 / 1.G AUDI AUDI https://www.carmanualsonline.info/img/6/999/w960_999-0.png AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System

Page 3 of 135

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System 24-3
 
  
5 - 
EVAP canister purge regulator valve -N80-
6 - 
Power output stage -N122- 
5-pin connector: signal wiring from ECM4-pin connector: coil primary circuit 
connections 
7 - 
Mass Air Flow (

Page 5 of 135

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System 24-5
      
Safety precautions
 
     
WARNING! 
     
Fire hazard! Do not smoke, work near heaters 
or open flame, or have anything nearby that 
could ignite fuel. The fuel system is under 
pressure.

Page 25 of 135

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System 24-17
      
Heated Oxygen Sensor (HO2S) and 
oxygen sensor control (before TWC), 
checking
 
     
Notes:  
     
Connector for Heated Oxygen Sensor (HO2S) 
before Three Way Catalytic Converter (TWC)

Page 34 of 135

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System 24-23
 Evaluation of display group 33  Display group: 
33  
  
  
Display field: 2  
Possible cause  
Corrective action  
approx. 0.435 
V   
Open circuit in wiring between HO2S connector terminal 4 a

Page 35 of 135

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System 24-24
      
Checking HO2S reference voltage  
     
-  Disconnect 4-pin connector -1- (brown) for 
HO2S -G39-. 
    
If voltage is NOT OK:  
If voltage is OK:  -  Connect multimeter US 1119 (Fluke 83

Page 36 of 135

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System 24-25
      
Checking HO2S wiring  
     
-  Connect VAG 1598/22 test box to ECM harness 
connector  Page 01
-56
 . 
     
-  Disconnect 4-pin connector (brown) for HO2S -
G39-. 
    
-  Check wiring

Page 37 of 135

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System 24-26
       If wiring is OK:  
     
-  Replace Motronic ECM -J220-   Page 01
-57
 .
     
-  Carry out adaptation of throttle valve control 
module to ECM   Page 24
-119
 . 
     
- Check readiness

Page 38 of 135

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System 24-27
      
Oxygen Sensor (O2S) heater (before 
TWC), checking
 
     
Notes:  
     
Harness connector for Oxygen Sensor (O2S) 
heater: 4-pin, brown 
     Component locations   Page 24
-1 .
     
Re

Page 45 of 135

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System 24-32
       If there is no voltage:  
    
If there is still no voltage:  -  Connect multimeter between harness connector terminal 1 (to ECM) 
and vehicle Ground, using VW 1594 connector test kit.

Page 47 of 135

AUDI A8 2000 D2 / 1.G AEB Engine Motronic MFI And Ignition System 24-34
       If there is no voltage:  
     
-  Connect VAG 1598/22 test box to ECM harness 
connector  Page 01
-56
 . 
    
If wiring is OK:  -  Check wiring for open circuit between ECM/test box and