CONVERTIBLE TOP STORAGE LID POSITION HALL SENSOR TESTS
Before testing always verify pin numbers and
wire colors from the appropriate ETM.
DC Voltage Test Procedures:
•At X13145 disconnect and access ground
(pin 6) and the hall sensor supply voltage
(pin 3) = battery voltage.
•Re-connect plug and check hall sensor sig-
nal (pin 2), activate convertible top, with
storage lid in motion = 5.0 volts.
Tap switch to display high/low signal - High = 10.0 volts.
Low = 0 volts.
Voltage Frequency Test Procedure:
•With storage compartment lid moving in either direction, pin 2 = 70 Hz.