Page 22 of 394
Downloaded from www.Manualslib.com manuals search engine 16
OPERATION No MA. 000 : ( rc,rlc,rNI cJ7nrncIerislic.s
Interior dimensions of the driver’s compartment :
I Distance between windscreen and separatinq panels . . . . . .
1 330 m ( 4 ft. 4 l/4 ins )
Width at elbow heiqht . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .._........ ,.....,............., _._._....._..
1.400 m ( 4 ft. 7 ins )
Interior dimensions of patient comportment :.
- Distance between separatinq panel and rear window (at stretcher heiqht ) .._..._.. 2.180 m ( 7 ft. 1 3/4 ins )
_ Width between rear side doors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . _._.. 1.400 m ( 4 ft. 7 ins )
_ Width of floor between rear wheelarches _.... 1.120 m ( 3 ft. 8 ins )
- Height between floor and roof
- at the front .._.._....,.......,..,,,,,,..,.,._..._.. _....................................... 1.420 m ( 4 ft. 8 ins )
- at the rear . . .._....._..__..._._._.......... .._.. .._._._.. 1.175 m ( 3 ft. 10 l/4 ins)
Weights in kg ( lb ) :
- Kerb weight ................................................................................................... 1530 ( 3373 )
- Weight on front axle
..................... ............................................... ...................... 925 ( 2039 )
- Weight on rear axle
.... 605 ( 1334 )
- Gross Vehicle Weight ( G.V.W. ) ........................................................................... 2095 ( 4619 )
- Maximum authorised weight on front axle ........................................................ 1075 ( 2370 )
- Maximum authorised weight on rear axle ‘1030 ( 2271 ) ...........................................................
111. GENERAL INFORMATION
Capacities :
- Fuel tank ............................................................................................................ 68 litres ( 15 galls )
- Cooling system ( including the heater units ) ....................................................... 11.8 litres ( 20.8 pts )
- Heater unit for driver compartment alone .............................................................. 0.6 litres ( 1.05 pts )
- Auxiliary heater unit for patient compartment ................................................... 1.6 litres ( 2.8 pts )
- Engine oil
- after draining ................................................................................................ 4.650 litres ( 8.2 pts )
- difference between Min. and Max. on dipstick ...................... . .......................
i.i litres ( 1.9 pts )
- tiydraulic system ( approx. )
.......... . ..................................................................... 4 litres ( 7 pts )
- Gearbox :
- after draining ............................................................................................... 1.6 litres ( 2.8 pts )
-difference between Min. and Max. on dipstick
.............................................. 0.150 litres ( 0.26 pts )
Page 50 of 394
Downloaded from www.Manualslib.com manuals search engine 4
OPERATION No MA. 03 : K C’C c ,I,,, ~,~‘,r’dVd nln/c~rinls
NAME
AGIR
BARTHELEMY
BOSTIK S.A.
BRASSART J
ETN BREGER
CEFILAC
( Department joint Curty )
C.F.R. ( TOTAL )
COMET
(Department D.A.V.A. 1
COLFIX ( SCHULTZ )
DISIMPEX
DOW-CORNING S.A.R.L.
LAMBERT-RIVIERE
MAGNUS
METOLUX S.A. FRANCE
(Societe Henri Lecocq 1
MINNESOTA DE FRANCE
MIPLACOL
MOLYDAL
MULLER & Cie
ONFROY
P.C.A.S.
RAVICOLOR
REDEX--FRANCE
REST-AGRAF
S.E.B.I.S.
SOFRALUS-BARDAHL
TEROSON LIST dF MANUFACTURERS
ADDRESS
6936G SEREZIN du RHDNE .......
61, rue Defiance 943G0 VINCENNES ...........................................
5, route de St Leu 95360 MONTMAGNY ......................................
44, rue de la Boetie 75008 PARIS ...............................................
Le Pasty St Aubin de Luigne 49190 ROCHEFORT LOIRE .......
25, rue Aristide Briand 69800 SAINT PRIEST ..........................
or 7 a 11, rue de la Py 75020 PARIS ..........................................
11, rue du Docteur Lancereaux 75381 PARIS CEDEX 08 .......
10, rue Eugene Cazeau 60300 Z.I. de SENLIS ...........................
43, route de la Metzeau 68100 MULHOUSE ................................
1, rue Goethe 75016 PARIS ...........................................................
140, avenue Paul Doumer 92500 RUEIL MALMAISON ..............
16, rue de Miromesnil 75008 PARIS .............................................
12, rue du Moulin de Cage 92390 VILLENEUVE LA GARENNE
167, rue de Fontenay 94300 VINCENNES ...................................
135, boulevard Serurier 75019 PARIS, ..........................................
52, avenue de la Concorde 93270 SEVRAN ................................
60, rue des Orteaux 75020 PARIS ................................................
28, avenue de 1 Opera 75002 PARIS ............................................
35, rue L. Sampaix 75010 PARIS .................................................
23, rue Bossuet 91160 LONGJUMEAU ........................................
32, rue de Mulhouse .. 68304 St LOUIS ...........................................
86, avenue de la Republique 93300 AUBERVILLIERS .............
6, place du General Leclerc 92300 LEVALLOIS .......................
3 a 5, rue de Metz 75010 PARIS ...................................................
27, boulevard du General Leclerc BP 29 - 59051 ROUBAIX .....
175 a 179, avenue J. Jaures _ 75019 PARIS ................................. TELEPHONE
( 78 ) 49.80.27
328.42.87
964.64.12
359.54.82
(41 1 41.73.03
(78 ) 20.08.94
797.01.49
267.15.00
453.13.20
( 89 ) 42.10.84
727.89.59
977.00.40
265.16.50
798.13.30
808.55.11
202.80.80
939.85.36
797.28.30
742.58.36
206.84.70
909777.85
(89) 67.13.37
352.75.94
757.67.34
770.13.08
(20 ) 70.02.1
202.50.72
Page 149 of 394
Downloaded from www.Manualslib.com manuals search engine 28 OPERATION N” MA.IE. 144-O : Ch <,c ,ng n,,d nlfjusfiup Ihe u I.-~<~tro,,ir i) <~lrr/mr,ir k’
/,,,.I i,,jrr/io,, S~S,W1, ANNEXE : D - ADJUSTING THE IDLING SPEED AND THE EXHAUST EMISSION
CHECKING CONDITIONS
1.
Checking the idling speed must be carried out
on a clean engine on which the ignition and the
valve clearances are properly adjusted and
fitted with a clean air-filter.
2. Check that the throttle butterfly returns correctly
to its stop.
3. Do not load the alternator by switching an any
of the electrical components, except the iqnition
and the electric cooling fan (s) 4.
Run the engine to bring the oil temperature up
to 70 +o 80’ C ( wait for the electric cooling
fan is) to cut in ). IMPORTANT : Use exclusively (I high tension
tachometer ( do not damage the H.T. lead of
the ignition wiring harness ).
ADJUSTMENT
1. Check that the butterfly is not jammed in position
when it is resting against its stop.
2. Wait for the electric cooling fan (s) to cut in.
3. Use screw ( 1 ) to adjust the idling speed to 850
to 900 rpm.
4. Check the exhaust emission :
The resulting amount of CO - CO2 ( corrected CO
reading 1 must be beI& 4.5 %.
In case this reading cannot be obtained, check the
valve clearances, the ignition, the fuel pressure,
the air-tightness of the aircircuit, and the complete
fuel injection system.
5. On (I vehicle fitted with optional oirtonditioning
switch the compressor on, and adjust the idling
speed from 1000 to 1050
rpm, by adjusting the
screw on the auxiliary box located next to the
electro-vol”e.
Page 179 of 394
Downloaded from www.Manualslib.com manuals search engine 2 OPERATION No MA. 230-O : II .h’ 0, fug Ol, I/7‘, rodir,p sys/w1.
b) by replacing the header tank cap with a
flexible rocker-cover union
I V~~/7id<~S 2/ IU7h - ,
7. Run engine at approximately 2000 rpm until
electric fan (5) cut (5) in.
Then let the engine idle for about 10 mins.
Never open header tank cap while electric fan (5)
ore/is in operation.
Do not open bleed-screws ( 1 ) and (2) while engine
is running.
8. After releasing the air. water level should
stabilize in header tank. Level should be checked
when the engine is cold.
9. Fit the rubber covers cm the bleed-screws.
Replace spare wheel.
II. PARTIAL FILLING
Same operations as for total filling except that
the heater unit is not filled by outlet tube ( 3)
to the radiator.
111. FILLING AND DE-AERATING THE AUXILIARY
HEATER UNIT ON CX AMBULANCE VEHICLES
Before connecting the auxiliary heater unit water
system to the main system. the following must
be carried out :
- Fill up the auxiliary heater unit and its hoses
( with heater control open I with 1.6 litres
( 2.8 pts 1 of coolant liquid of the some type
as that used in the main
system.
- Connect all hoses. and tiqhten 011 hose clips.
-Stat engine. and wait for electric fan (5) to
to cut-in ( De-aeration time 1.’
- Check the operation of the auxilioly heater unit.
- WHEN THE ENGINE IS COLD, check the level,
and top up if necessary.