Radiator Citroen XSARA PICASSO 2004 1.G Workshop Manual
[x] Cancel search | Manufacturer: CITROEN, Model Year: 2004, Model line: XSARA PICASSO, Model: Citroen XSARA PICASSO 2004 1.GPages: 523, PDF Size: 10.32 MB
Page 498 of 523
![Citroen XSARA PICASSO 2004 1.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine 494
AIRCONAIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Tools.
[1]
Charge station :(accord Citroen XSARA PICASSO 2004 1.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine 494
AIRCONAIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Tools.
[1]
Charge station :(accord](/img/9/4135/w960_4135-497.png)
Downloaded from www.Manualslib.com manuals search engine 494
AIRCONAIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Tools.
[1]
Charge station :(according to workshop equipment)[2]TORX adaptor: TORX 70 FACOM
Removing.
Depressurise the aircon circuit, using tool [1].
Uncouple the hose
(2).
Remove:
The air filter assembly
(3).
The nuts (1).
Protect the radiator harness with strong cardboard cut to the dimensions of the radiator.
Move aside the cooling fan.
Remove:
The screws
(4).
The brackets (5).
B1BP23FCB1BP23GC
XSARA PICASSO
Page 499 of 523

Downloaded from www.Manualslib.com manuals search engine 495
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Move aside the radiator/condenser assembly.
Remove the plug (6), using tool [2].
Support the radiator/condenser assembly thus moved aside.
Remove the filtering/drying cartridge
(7), using pliers.
Refitting.Refit the filtering/drying cartridge (7).
Clean the threads of the plug (6).
It is essntial to change the O ring seals (8).
Lubricate the O ring seals (8)with aircon compressor oil.
Refit:
The plug
(6), using tool [2], tighten to 1,4 ±0,2 m.daN.
The brackets (5).
The screws (4).
The cardboard from the radiator harness.
The nuts
(1).
The air filter assembly (3).
Couple the hose (2).
Recharge the circuit (R134.a) (according to equipment)
(see corresponding operation).
Check the operation of the air conditioning.
C5HP14NCC5HP14PCC5HP14QC
XSARA PICASSO