Ground HONDA CIVIC 2000 6.G Workshop Manual

HONDA CIVIC 2000 6.G Workshop Manual CIVIC 2000 6.G HONDA HONDA https://www.carmanualsonline.info/img/13/6068/w960_6068-0.png HONDA CIVIC 2000 6.G Workshop Manual

Page 1405 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Blower Motor
BLOWER MOTOR 2P CONNECTOR
Wire side of lemale terminals
JUMPERWIRE
(contd)
21-31
Blower motor does not run at all.
Check the No. 55 (40 A) Iuse in
the under-hood fuse/relay box,
and the

Page 1406 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Troubleshooting -99 - 00 Models
From page 21-31
Check the blower motor relay:1. Turn the ignition switch OFF.2. Remove the blower motorrelay from the under hoodfuse/relay box, and test it- (seepage 2

Page 1407 of 2189

HONDA CIVIC 2000 6.G Workshop Manual From page 21 31
ls there continuity?
YES
Check the blower motor highrelay:1. Turn the ignition switch OFF,and disconnect the iumPer
2. Remove the blower motor
high relay, and test it. {seepage 21 49).

Page 1409 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Both heater and A/C do nol work.
checkthe No.47 (7.5 A)fuse in the
under-hood fuse/relay box, and theNo. 17 {7.5 A) fuse in the under-
dash fuse/relay box.
ReDlace the tuse{s), and recheck.
Check lor

Page 1410 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Troubleshooting -99 - 00 Models
Heater Control Panel Input/Output Signals
HEATER CONTROL PANEL CONNECTORS
8P CONNECTOR2OP CONNECTOR12P CONNECTOR
Wire side of female terminals
8P CONNECTOR (O qn Circu

Page 1412 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Blower Unit
Overhaul
NOTE:
RECIRCULATIONCONTROL MOTORTest, page 21-48
aBefore reassembly. make sure that the recirculation control door and linkage move smoothly without binding.
When attaching the re

Page 1420 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Air Mix Gontrol Motor
t.
Test -99 - 00 Models
Disconnect the 5P connector from the air mix con-
trol motor.
Connect battery power to the No. 1 terminal of the
air mix control motor, and ground the N

Page 1421 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Mode Control Motor
2.
Test
1.
4.
Disconnect the 7P connector from the mode control
motor.
Connect battery power to the No, 1 terminal, and
ground the No.7 terminal,
CAUTION: Never connecl the battery

Page 1422 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Recirculation Control Motor
Test
LDisconnect the 4P connector from the recirculation
control motor.
Connect battery power to the No. I terminal, andground the No.2 and No. 4 terminals; the recircula-

Page 1423 of 2189

HONDA CIVIC 2000 6.G Workshop Manual RelaysHeater Fan Switch
Test
There should be continuity between the No 1 and No. 3
terminals when power and ground are connected to the
No.2 and No. 4 terminals, and there should be no conta-
nuity wh