Starter INFINITI M35 2007 Factory Owner's Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2007, Model line: M35, Model: INFINITI M35 2007Pages: 4647, PDF Size: 93.69 MB
Page 1079 of 4647

BL-146
INTELLIGENT KEY SYSTEM/ENGINE START FUNCTION
Revision: 2007 April2007 M35/M45
Terminals and Reference Value for IPDM E/RNIS001YH
Te r -
minal
No.Wire
ColorItemSignal
Input/
OutputCondition
Voltage (V)
(Approx.) Push-
button
ignition
switch
positionOperation or conditions
4 W/R Starter motor power supply InputLOCK — 0
START Starter motor is activating Battery voltage
49 L CAN HInput/
Output—— —
50 P CAN LInput/
Output—— —
53 GR/R Shift position signal InputONA/T selector lever is in N or P
positionBattery voltage
LOCKA/T selector lever is in any
position other than P and N
position0
Page 1080 of 4647

INTELLIGENT KEY SYSTEM/ENGINE START FUNCTION
BL-147
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
Terminals and Reference Value for PDUNIS001YI
Te r -
minal
No.Wire
colorItemSignal
Input/
OutputCondition
Voltage (V)
(Approx.) Push-
button
ignition
switch
positionOperation or conditions
1 P Wake up signal InputLOCKSleep condition (30 seconds or more
after all doors are closed under the
condition that the power supply posi-
tion is in the LOCK position)Battery voltage
— Wake-up condition (Open driver door) 0
2 G Starter control signal InputON At starter motor cranking 0
— Any condition other than above Battery voltage
3GRSteering lock unit
power sourceOutputLOCKPush-button ignition switch is pressed
under the condition that Intelligent
Key is in the vehicle or Intelligent Key
is inserted0 → Battery voltage → 0
— Any condition other than above 0
6VSteering lock control
signal-1Input—Push-button ignition switch is pressed
under the condition that Intelligent
Key is in the vehicle or Intelligent Key
is insertedBattery voltage
LOCKPower supply position is in LOCK
position
(Steering lock activated)Battery voltage → 0 → Bat-
tery voltage
(Battery voltage is detected
when activating the steer-
ing lock)
7LGSteering lock control
signal-2Input—Push-button ignition switch is pressed
under the condition that Intelligent
Key is in the vehicle or Intelligent Key
is insertedBattery voltage
LOCKPower supply position is in LOCK
position
(Steering lock activated)Battery voltage → 0 → Bat-
tery voltage
(Battery voltage is detected
when activating the steer-
ing lock)
9OSteering lock feed
back signalOutput— Steering lock: Lock 0
LOCK Steering lock: Unlock 8
10 B Ground — — — 0
11 YIPDM E/R current
signalOutputSTART At starter motor cranking 5
LOCK Any condition other than above 2
12 R Feed back signal OutputLOCKSleep condition (30 seconds or more
after all doors are closed under the
condition that the power supply posi-
tion is in the LOCK position)1
—Wake-up condition (any condition
other than above)0
13 R Starter relay OutputSTART At starter motor cranking Battery voltage
— Any condition other than above 4
14 SB Power source (fuse) Input — — Battery voltage
15 LPower source (fus-
ible link)Input — — Battery voltage
17 GPower source (fus-
ible link)Input — — Battery voltage
Page 1084 of 4647
![INFINITI M35 2007 Factory Owners Manual INTELLIGENT KEY SYSTEM/ENGINE START FUNCTION
BL-151
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
CAUTION:
When CAN COMM CIRCUIT [U1000] and CONTROL UNIT (CAN) [U1010] are displayed, giv INFINITI M35 2007 Factory Owners Manual INTELLIGENT KEY SYSTEM/ENGINE START FUNCTION
BL-151
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
CAUTION:
When CAN COMM CIRCUIT [U1000] and CONTROL UNIT (CAN) [U1010] are displayed, giv](/img/42/57024/w960_57024-1083.png)
INTELLIGENT KEY SYSTEM/ENGINE START FUNCTION
BL-151
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
CAUTION:
When CAN COMM CIRCUIT [U1000] and CONTROL UNIT (CAN) [U1010] are displayed, give priority to performing trouble diag-
nosis.
DATA MONITOR
IGN POWER CIRCUIT
[B2553]It continues for 2 seconds or more that ON power sup-
ply input to Intelligent Key unit is excessively low when
the power supply position is in ON positionCheck Intelligent Key
unit ON power supply
inputBL-161
ACC POWER CIRCUIT
[B2554]It continues for 2 seconds or more that ACC power
supply input to Intelligent Key unit is excessively low
when the power supply position is in ACC or ON posi-
tionCheck Intelligent Key
unit ACC power supply
inputBL-162
STOP LAMP CIRCUIT
[B2555]5V or less is detected at both the stop lamp switch sig-
nal input circuit that is input to Intelligent Key unit and
the monitor input before stop lamp switchCheck stop lamp switchBL-165
ENG START SW
[B2556]Condition that push-button ignition switch is pushed is
detected continuously for 100 seconds or moreCheck push-button igni-
tion switchBL-166
VEHICLE SPEED
[B2557]Some differences occur on one or more vehicle speed
inputs of Intelligent Key unitCheck vehicle speed sig-
nalBL-167
SHIFT POSITION
[B2558]
There is a difference between the shift position input
via CAN communication and the P position input by
detent switch
Vehicle speed (5 km/h or more) is detected continu-
ously for 10 seconds or more even if the shift posi-
tion is detected in P position when the power supply
position is in ON positionCheck shift position inputBL-170
PDU
[B2559]Internal malfunction is detected in PDU Replace PDUBL-172
START POW SUP CIRC
[B2560]Though the engine start operation is not performed,
starter relay in IPDM E/R is ONCheck starter power sup-
plyBL-172
LOW VOLTAGE
[B2562]Battery power supply input to Intelligent Key unit (8.8V
or less) is detected continuously for 1.5 seconds or
moreCheck battery low volt-
ageBL-175
HI VOLTAGE
[B2563]Battery power supply input to Intelligent Key unit (18V
or more) is detected continuously for 90 seconds or
moreCheck for battery high
voltageBL-176
NATS MALFUNCTION
[B2590]Malfunction is detected in immobilizer systemCheck (IVIS) NATS trou-
ble diagnosis procedureBL-265
Suspect Systems
[DTC]Diagnostic item is detected when... Repair work Reference page
Monitor item Content
DR REQ SW Indicates [ON/OFF] condition of door request switch (driver side).
AS REQ SW Indicates [ON/OFF] condition of door request switch (passenger side).
BD/TR REQ SW Indicates [ON/OFF] condition of trunk opener request switch.
ON POS Indicates [ON/OFF] condition of ignition switch in ON position.
ACC POS Indicates [ON/OFF] condition of ignition switch in ACC position.
DOOR STAT SW Indicates [ON/OFF] condition of door unlock sensor.
STOP LAMP SW Indicates [ON/OFF] condition of stop lamp switch.
P RANGE SW Indicates [ON/OFF] condition of park position switch.
TR CANCEL SW* Indicates [ON/OFF] condition of trunk cancel switch.
DOOR LOCK SIG* Indicates [ON/OFF] condition of door lock signal from Intelligent Key remote controller button.
DOOR UNLOCK SIG* Indicates [ON/OFF] condition of door unlock signal from Intelligent Key remote controller button.
KEYLESS TRUNK* Indicates [ON/OFF] condition of trunk open signal from Intelligent Key remote controller button.
KEYLESS PANIC* Indicates [ON/OFF] condition of panic alarm signal from Intelligent Key remote controller button.
Page 1103 of 4647

BL-170
INTELLIGENT KEY SYSTEM/ENGINE START FUNCTION
Revision: 2007 April2007 M35/M45
DTC B2558 SHIFT POSITIONNIS001YV
DIAGNOSIS DESCRIPTION
B2558 shift position input system monitors the A/T selector lever position. If there is the difference between
the input from A/T device, the input from A/T assembly, and CAN communication input from A/T control unit, it
judges that it is the malfunction and displays the DTC (Diagnostic Trouble Code)
TERMINALS AND REFERENCE VALUE FOR INTELLIGENT KEY UNIT
SELF-DIAGNOSTIC LOGIC
DIAGNOSTIC PROCEDURE
1. CHECK A/T DEVICE SIGNAL
1. Turn ignition switch ON.
2. Check voltage between Intelligent Key unit connector and ground.
OK or NG
OK >> GO TO 4.
NG >> GO TO 2.
Te r m i -
nal
No.Wire
colorItemCondition
Voltage (V)
(Approx.) Push-
button
ignition
switch
positionOperation or conditions
27 VA/T device (Detention
switch)LOCK A/T selector lever is in P position 0
ONA/T selector lever is in any position
other than PBattery voltage
28 SB Starter relayON A/T selector lever is in N or P position Battery voltage
—Power supply position is in LOCK
position or A/T selector lever is in any
position other than N or P position0
58 OA/T device (Detention
switch)LOCKAt sleep (30 seconds or more after all
doors are closed under the condition
that the power supply position is in the
LOCK position)0
— At wake-up (Open driver door) Battery voltage
DTC Self-diagnosis name DTC detecting condition Possible causes
B2558 SHIFT POSITIONThere is an input difference of A/T selector
lever position input to Intelligent Key unit for 2
seconds or more
Harness and connector
(Open in the circuit between the units)
A/T device (detent switch)
A/T assembly (control valve assembly)
Terminals
A/T con-
trol device
positionVoltage (V)
(Approx.) (+)
(–)
Intelligent Key unit
connectorTerminal
M32 27 GroundP0
Other than
aboveBattery voltage
PIIB6244E
Page 1105 of 4647

BL-172
INTELLIGENT KEY SYSTEM/ENGINE START FUNCTION
Revision: 2007 April2007 M35/M45
4. CHECK TCM SIGNAL
Check Intelligent Key unit connector and ground.
OK or NG
OK >> Check the condition of harness and connector. If it is
OK, check the self-diagnosis results using CONSULT-II
again.
NG >> GO TO 5.
5. CHECK HARNESS CONTINUITY 2
1. Turn ignition switch OFF.
2. Disconnect Intelligent Key unit and TCM connector.
3. Check continuity between Intelligent Key unit connector and TCM connector.
4. Check continuity between Intelligent Key unit connector and
ground.
OK or NG
OK >> Replace TCM.
NG >> Repair or replace harness.
DTC B2559 PDUNIS001YW
DIAGNOSIS DESCRIPTION
B2559 PDU system that is Intelligent Key unit judges NG by self-detecting the PDU (Power Distribution Unit)
internal malfunction.
If this DTC (Diagnostic Trouble Code) is displayed, replace the PDU.
DTC B2560 START POW SUP CIRCNIS001YX
DIAGNOSIS DESCRIPTION
B2560 starter power supply system monitors the power supply condition to the starter motor relay and the
starter motor relay condition in IPDM E/R. If it detects the starter motor relay ON condition in IPDM E/R without
the “Engine start” request from the Intelligent Key unit, it judges that it is the malfunction and displays the DTC
(Diagnostic Trouble Diagnosis).
Terminals
A/T con-
trol device
positionVoltage (V)
(Approx.) (+)
(–)
Intelligent Key unit
connectorTerminal
M32 28 GroundN or P Battery voltage
Other than
above0
PIIB6247E
AB
Continuity
Intelligent Key
unit connectorTerminal TCM connector Terminal
M32 28 F502 8 Yes
A
GroundContinuity
Intelligent Key unit connector Terminal
M32 28 No
PIIB6248E
Page 1106 of 4647

INTELLIGENT KEY SYSTEM/ENGINE START FUNCTION
BL-173
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
TERMINALS AND REFERENCE VALUE
Intelligent Key Unit
PDU (Power Distribution Unit)
SELF-DIAGNOSTIC LOGIC
DIAGNOSTIC PROCEDURE
1. CHECK HARNESS CONTINUITY 1
1. Turn ignition switch OFF.
2. Disconnect Intelligent Key unit and power distribution unit connector.
3. Check continuity between Intelligent Key unit connector and power distribution unit connector.
4. Check continuity between Intelligent Key unit connector and
ground.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
Te r m i -
nal
No.Wire
colorItemCondition
Voltage (V)
(Approx.) Push-
button
ignition
switch
positionOperation or conditions
3YIPDM E/R current sig-
nalSTART At starter motor cranking 5
LOCK Any condition other than above 2
Te r -
minal
No.Wire
colorItemCondition
Voltage (V)
(Approx.) Push-
button
ignition
switch
positionOperation or conditions
13 R Starter relaySTART At starter motor cranking Battery voltage
— Any condition other than above 4
DTC Self-diagnosis name DTC detecting condition Possible causes
B2560START POW SUP
CIRCIt is detected that the power is supplied to the
starter motor without the engine start request from
the Intelligent Key unit
Harness and connector
(Open in the circuit between
the units)
PDU
IPDM E/R
AB
Continuity
Intelligent Key
unit connectorTerminalPower distribution
unit connectorTerminal
M32 3 M30 11 Yes
A
GroundContinuity
Intelligent Key unit connector Terminal
M32 3 No
PIIB6249E
Page 1180 of 4647

IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
BL-247
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
Operation DescriptionNIS0020E
SYSTEM DIAGRAM
OPERATION WHEN INSERTING TO KEY SLOT
1. When inserting the Intelligent Key (with transponder) into the key slot, the key switch in the key slot turns
ON, and then it is detected that the Intelligent Key is inserted.
2. When pressing the push-button ignition switch at that time, BCM starts the IVIS (NATS) antenna amplifier
integrated with the key slot and starts the IVIS (NATS) ID communication with the transponder integrated
with the Intelligent Key.
3. BCM sends the IVIS (NATS) ID verification result to ECM via CAN communication and performs the ID
verification.
4. If the IVIS (NATS) ID verification result is OK, BCM sends the key ID verification OK signal to Intelligent
Key unit via CAN communication line.
5. The Intelligent Key unit sends the steering unlock signal to the steering lock unit when receiving the sig-
nal. Then, it sends each power supply request signal to PDU (Power Distribution Unit) after unlocking the
steering lock.
6. If the Intelligent Key unit judges that the engine start condition is satisfied, it sends the starter request sig-
nal via CAN communication to IPDM E/R and turns the starter motor relay ON.
7. The steering lock unit unlocks the latch when receiving the signal. PDU starts the power distribution
according to the power supply position when receiving the signal.
NOTE:
If it is not in the engine start condition*, the starter motor relay is turned OFF. Therefore, the engine cannot be
started and the power distributions of ACC, ON, and LOCK are performed only according to the push-button
ignition switch operation.
*: For the engine start condition, refer to BL-247, "
PUSH-BUTTON IGNITION SWITCH OPERATION PROCE-
DURE" .
OPERATION WHEN INTELLIGENT KEY IS CARRIED
By carrying the Intelligent Key, the engine start/stop operation can be performed only when pushing the push-
button ignition switch.
For the details of the function, refer to BL-125, "
INTELLIGENT KEY SYSTEM/ENGINE START FUNCTION" .
PUSH-BUTTON IGNITION SWITCH OPERATION PROCEDURE
The power supply position changing operation can be performed with the following operation.
NOTE:
When an Intelligent Key is carried and when it is inserted to the key slot, the following operation is the
same.
When starting the engine, the Intelligent Key unit monitors the engine start conditions (brake pedal opera-
tion, A/T selector lever position, vehicle speed, and steering lock condition).
PIIB6277E
Page 1193 of 4647

BL-260
IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
Revision: 2007 April2007 M35/M45
Terminals and Reference Value for Intelligent Key UnitNIS0020I
Termi-
nal
No.Wire
colorItemSignal
Input/
OutputCondition
Voltage (V)
(Approx.) Push-
button
ignition
switch
positionOperation or conditions
1 SB Power source (fuse) Input — — Battery voltage
3YIPDM E/R current sig-
nalInputSTART At starter motor cranking 5
LOCK Any condition other than above 2
8WPush-button ignition
switch LOCK indicatorOutputLOCKPower supply position is in LOCK
position0
—Power supply position is in any
position other than LOCK1.2
9LPush-button ignition
switch ACC indicatorOutputACCPower supply position is in ACC
position0
—Power supply position is in any
position other than ACC1.2
10 VPush-button ignition
switch ON indicatorOutputONPower supply position is in ON
position0
—Power supply position is in any
position other than ON1.2
13 LG/B Key slot illumination Output LOCKDriver door is opened under the
condition that the Intelligent Key is
inserted into the key slot0 → Battery voltage → 0
Intelligent Key is removed from
key slot (when key slot illumination
is turned off)0
15 LGSteering lock unit
power sourceOutput LOCK — Battery voltage
16 P/BSteering lock unit sig-
nalInput/
OutputLOCK Steering lock: Lock Battery voltage
ACCSteering lock: Unlock
(Unlocked moment)0
19 BR/Y Key switch Input LOCKIntelligent Key is inserted into key
slotBattery voltage
Intelligent Key is removed from
key slot0
20 B Ground — — — 0
27 VA/T device (Detention
switch)InputLOCK A/T selector lever is in P position 0
ONA/T selector lever is in any posi-
tion other than PBattery voltage
28 SB Starter relay InputONA/T selector lever is in N or P posi-
tionBattery voltage
—Power supply position is in LOCK
position or A/T selector lever is in
any position other than N or P
position0
29 V/R Stop lamp switch Input —Brake pedal depressed Battery voltage
Brake pedal released 0
30 L/WIgnition power supply
(ACC)Input ACCPower supply position is in ACC
positionBattery voltage
31 GRIgnition power supply
(ON)Input ONPower supply position is in ON
positionBattery voltage
Page 1194 of 4647

IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
BL-261
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
33 O PDU signal InputLOCK Steering lock: Lock 0
ACC Steering lock: Unlock 8
34 R PDU feed back signal Input LOCK At wake-up (Open driver door) 0
35 LG Vehicle speed signal Input ONAt speedometer operation (vehicle
speed approx. 40 km/h)
37 P CAN LInput/
Output—— —
38 L CAN HInput/
Output—— —
39 BR/WPush-button ignition
switchInput —Push-button ignition switch is
pressed0
Push-button ignition switch is
releasedBattery voltage
40 B Ground — — — 0
41 Y Power source (fuse) Input — — Battery voltage
42 P PDU wake up signal OutputLOCKAt sleep (30 seconds or more after
all doors are closed under the con-
dition that the power supply posi-
tion is in the LOCK position)Battery voltage
— At wake-up (Open driver door) 0
43 G Starter signal OutputON At starter motor cranking 0
— Other than above Battery voltage
46 V PDU signal Output— Steering lock: Lock Battery voltage
LOCK Steering lock: Unlocked moment 0
56 B Ground — — — 0
57 L Power source (fuse) Input — — Battery voltage
58 OA/T device (Detention
switch)InputLOCKAt sleep (30 seconds or more after
all doors are closed under the con-
dition that the power supply posi-
tion is in the LOCK position)0
— At wake-up (Open driver door) Battery voltage
63 P Stop lamp switch Input —Brake pedal depressed Battery voltage
Brake pedal released Battery voltage
64 L/RPush-button ignition
switch illuminationOutput —Push-button ignition switch illumi-
nation is turned on2.6
Push-button ignition switch illumi-
nation is turned off
(15 seconds or more after the
driver door is closed)0 Te r m i -
nal
No.Wire
colorItemSignal
Input/
OutputCondition
Voltage (V)
(Approx.) Push-
button
ignition
switch
positionOperation or conditions
PKIA1935E
Page 1196 of 4647

IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
BL-263
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
Terminals and Reference Value for BCMNIS0020K
Terminals and Reference Value for IPDM E/RNIS0020L
Termi-
nal
No.Wire
colorItemSignal
Input/
OutputCondition
Voltage (V)
(Approx.) Push-but-
ton igni-
tion
switch
positionOperation or conditions
21 GRNATS antenna
amp.
(Built-in key slot)Input/
OutputLOCKIgnition switch is pressed
while inserting the Intelligent
Key into the key slotJust after pressing ignition switch.
Pointer of tester should move
23 W/V Security indicator Output LOCKIntelligent Key is removed
from key slot and power sup-
ply position is in LOCK posi-
tionBattery voltage → 0
(Every 2.4 seconds)
25 W/RNATS antenna
amp.
(Built-in key slot)Input/
OutputLOCKIgnition switch is pressed
while inserting the Intelligent
Key into the key slotJust after pressing ignition switch.
Pointer of tester should move
37 LGKey slot
(Key switch signal)Input LOCKIntelligent Key is removed
from key slot0
Intelligent Key is inserted into
key slotBattery voltage
38 WIgnition power sup-
ply (ON or START)Input ONPower supply position is in
ON positionBattery voltage
39 L CAN HInput/
Output—— —
40 P CAN LInput/
Output—— —
42 PPower source
(fuse)Input — — Battery voltage
52 B Ground — — — 0
55 WPower source
(Fusible link)Input — — Battery voltage
Te r m i -
nal No.Wire
ColorItemSignal
Input/
OutputCondition
Voltage (V)
(Approx.) Push-button
ignition switch
positionOperation or conditions
4W/RStarter motor power
supplyOutputLOCK — 0
START Starter motor is activating Battery voltage
49 L CAN HInput/
Output—— —
50 P CAN LInput/
Output—— —
53 GR/RA/T Shift position
signalInputON A/T shift position is P/ N position Battery voltage
LOCK Other than above 0