turn signal INFINITI M35 2007 Factory Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2007, Model line: M35, Model: INFINITI M35 2007Pages: 4647, PDF Size: 93.69 MB
Page 2412 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
EC-883
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATERPFP:22693
DescriptionNBS INFINITI M35 2007 Factory Service Manual DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
EC-883
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATERPFP:22693
DescriptionNBS](/img/42/57024/w960_57024-2411.png)
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
EC-883
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATERPFP:22693
DescriptionNBS005BH
SYSTEM DESCRIPTION
The ECM performs ON/OFF duty control of the A/F sensor 1 heater corresponding to the engine operating
condition to keep the temperature of A/F sensor 1 element at the specified range.
CONSULT-II Reference Value in Data Monitor ModeNBS005BI
Specification data are reference values.
On Board Diagnosis LogicNBS005BJ
DTC Confirmation ProcedureNBS005BK
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 11V and 16V at
idle.
WITH CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Wait at least 5 seconds.
3. If 1st trip DTC is detected, go to EC-887, "
Diagnostic Procedure"
.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
Sensor Input Signal to ECM ECM function Actuator
Camshaft position sensor (PHASE)
Crankshaft position sensor (POS)Engine speed
Air fuel ratio (A/F) sensor 1
heater controlAir fuel ratio (A/F) sensor 1
heater
Mass air flow sensor Amount of intake air
MONITOR ITEM CONDITION SPECIFICATION
A/F S1 HTR (B1)
A/F S1 HTR (B2)
Engine: After warming up, idle the engine 0 - 100%
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0031
0031
(Bank 1)
Air fuel ratio (A/F) sensor 1
heater control circuit lowThe current amperage in the A/F sensor 1 heater
circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM
through the A/F sensor 1 heater.)
Harness or connectors
(The A/F sensor 1 heater circuit is
open or shorted.)
A/F sensor 1 heater P0051
0051
(Bank 2)
P0032
0032
(Bank 1)
Air fuel ratio (A/F) sensor 1
heater control circuit highThe current amperage in the A/F sensor 1 heater
circuit is out of the normal range.
(An excessively high voltage signal is sent to ECM
through the A/F sensor 1 heater.)
Harness or connectors
(The A/F sensor 1 heater circuit is
shorted.)
A/F sensor 1 heater P0052
0052
(Bank 2)
SEF058Y
Page 2416 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
EC-887
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each term INFINITI M35 2007 Factory Service Manual DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
EC-887
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each term](/img/42/57024/w960_57024-2415.png)
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
EC-887
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureNBS005BM
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground screws on the body.
Refer to EC-864, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
24 SBA/F sensor 1 heater
(bank 2)[Engine is running]
Warm-up condition
Idle speedApproximately 5V
57 BR/W
A/F sensor 1 (bank 2)[Engine is running]
Warm-up condition
Idle speedApproximately 2.6V
58 G/OApproximately 2.3V
76 G/WApproximately 3.1V
77 GRApproximately 2.3V
PBIB1584E
1. Body ground M70 2. Body ground M16
PBIB2782E
Page 2417 of 4647
![INFINITI M35 2007 Factory Service Manual EC-888
[VK45DE]
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
Revision: 2007 April2007 M35/M45
2. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
1. Disconnect air fuel ratio (A/F) senso INFINITI M35 2007 Factory Service Manual EC-888
[VK45DE]
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
Revision: 2007 April2007 M35/M45
2. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
1. Disconnect air fuel ratio (A/F) senso](/img/42/57024/w960_57024-2416.png)
EC-888
[VK45DE]
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
Revision: 2007 April2007 M35/M45
2. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
1. Disconnect air fuel ratio (A/F) sensor 1 harness connector.
2. Turn ignition switch ON.
3. Check voltage between A/F sensor 1 terminal 3 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E12, F3
IPDM E/R harness connector E7
15A fuse
Harness for open or short between A/F sensor 1 and fuse
>> Repair or replace harness or connectors.
4. CHECK A/F SENSOR 1 HEATER OUTPUT SIGNAL CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between the following;
ECM terminal 2 and A/F sensor 1 (bank 1) terminal 4 or
ECM terminal 24 and A/F sensor 1 (bank 2) terminal 4.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
: Vehicle front 1. A/F sensor 1 (bank 2)
harness connector2. A/F sensor 1 (bank 1)
harness connector
Voltage: Battery voltage
PBIB2715E
PBIB1683E
Continuity should exist.
Page 2426 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-897
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
4. CHECK HO2S2 HEATER OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition s INFINITI M35 2007 Factory Service Manual DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-897
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
4. CHECK HO2S2 HEATER OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition s](/img/42/57024/w960_57024-2425.png)
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-897
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
4. CHECK HO2S2 HEATER OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK HEATED OXYGEN SENSOR 2 HEATER
Refer to EC-897, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace malfunctioning heated oxygen sensor 2.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-857, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionNBS005BV
HEATED OXYGEN SENSOR 2 HEATER
1. Check resistance between HO2S2 terminals as follows.
2. If NG, replace heated oxygen sensor 2.
CAUTION:
Discard any heated oxygen sensor which has been dropped
from a height of more than 0.5 m (19.7 in) onto a hard sur-
face such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system
threads using Oxygen Sensor Thread Cleaner tool J-43897-
18 or J-43897-12 and approved anti-seize lubricant.
DTCTe r m i n a l s
Bank
ECM Sensor
P0037, P0038 6 3 1
P0057, P0058 25 3 2
Continuity should exist.
Terminal No. Resistance
2 and 3 5.0 - 7.0 Ω [at 25°C (77°F)]
1 and 2, 3, 4
∞ Ω
(Continuity should not exist)
4 and 1, 2, 3
PBIB0970E
Page 2428 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-899
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0075, P0081 IVT CONTROL SOLENOID VALVEPFP:23796
Component DescriptionNBS005B INFINITI M35 2007 Factory Service Manual DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-899
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0075, P0081 IVT CONTROL SOLENOID VALVEPFP:23796
Component DescriptionNBS005B](/img/42/57024/w960_57024-2427.png)
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-899
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0075, P0081 IVT CONTROL SOLENOID VALVEPFP:23796
Component DescriptionNBS005BX
Intake valve timing control solenoid valve is activated by ON/OFF
pulse duty (ratio) signals from the ECM.
The intake valve timing control solenoid valve changes the oil
amount and direction of flow through intake valve timing control unit
or stops oil flow.
The longer pulse width advances valve angle.
The shorter pulse width retards valve angle.
When ON and OFF pulse widths become equal, the solenoid valve
stops oil pressure flow to fix the intake valve angle at the control
position.
CONSULT-II Reference Value in Data Monitor ModeNBS005BY
Specification data are reference values.
On Board Diagnosis LogicNBS005BZ
DTC Confirmation ProcedureNBS005C0
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and
wait at least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and let it idle for 5 seconds.
4. If 1st trip DTC is detected, go to EC-904, "
Diagnostic Procedure"
.
WITH GST
Following the procedure “WITH CONSULT-II” above.
PBIB1842E
MONITOR ITEM CONDITION SPECIFICATION
INT/V SOL (B1)
INT/V SOL (B2)
Engine: After warming up
Selector lever: P or N
Air conditioner switch: OFF
No loadIdle 0% - 2%
2,000 rpm Approx. 25% - 50%
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0075
0075
(Bank 1)
Intake valve timing control
solenoid valve circuitAn improper voltage is sent to the ECM
through intake valve timing control solenoid
valve.
Harness or connectors
(Intake valve timing control solenoid valve
circuit is open or shorted.)
Intake valve timing control solenoid valve P0081
0081
(Bank 2)
SEF058Y
Page 2430 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-901
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal an INFINITI M35 2007 Factory Service Manual DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-901
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal an](/img/42/57024/w960_57024-2429.png)
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-901
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
10 W/GIntake valve timing control
solenoid valve (bank 1)[Engine is running]
Warm-up condition
Idle speedBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
Engine speed: 2,000rpm7 - 12V
111 S BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
11 9
120R
RPower supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
PBIB1790E
Page 2432 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-903
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal an INFINITI M35 2007 Factory Service Manual DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-903
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal an](/img/42/57024/w960_57024-2431.png)
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-903
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
11 G / OIntake valve timing control
solenoid valve (bank 2)[Engine is running]
Warm-up condition
Idle speedBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
Engine speed: 2,000rpm7 - 12V
111 S BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
11 9
120R
RPower supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
PBIB1790E
Page 2433 of 4647
![INFINITI M35 2007 Factory Service Manual EC-904
[VK45DE]
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
Revision: 2007 April2007 M35/M45
Diagnostic ProcedureNBS005C2
1. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Tu INFINITI M35 2007 Factory Service Manual EC-904
[VK45DE]
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
Revision: 2007 April2007 M35/M45
Diagnostic ProcedureNBS005C2
1. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Tu](/img/42/57024/w960_57024-2432.png)
EC-904
[VK45DE]
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
Revision: 2007 April2007 M35/M45
Diagnostic ProcedureNBS005C2
1. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect intake valve timing control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between intake valve timing control solenoid
valve terminal 2 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E12, F3
IPDM E/R harness connector E7
Harness for open or short between intake valve timing control solenoid valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR
OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between the following;
ECM terminal 10 and intake valve timing control solenoid valve (bank 1) terminal 1 or
ECM terminal 11 and intake valve timing control solenoid valve (bank 2) terminal 1.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
1. Intake valve timing control solenoid
valve (bank 2)2. Intake valve timing control solenoid
valve (bank 1)
Voltage: Battery voltage
PBIB2687E
PBIB0192E
Continuity should exist.
Page 2441 of 4647
![INFINITI M35 2007 Factory Service Manual EC-912
[VK45DE]
DTC P0101 MAF SENSOR
Revision: 2007 April2007 M35/M45
6. CHECK MAF SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check h INFINITI M35 2007 Factory Service Manual EC-912
[VK45DE]
DTC P0101 MAF SENSOR
Revision: 2007 April2007 M35/M45
6. CHECK MAF SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check h](/img/42/57024/w960_57024-2440.png)
EC-912
[VK45DE]
DTC P0101 MAF SENSOR
Revision: 2007 April2007 M35/M45
6. CHECK MAF SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between MAF sensor terminal 3 and ECM terminal 67.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK MAF SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between MAF sensor terminal 4 and ECM terminal 51.
Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 8.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK INTAKE AIR TEMPERATURE SENSOR
Refer to EC-925, "
Component Inspection" .
OK or NG
OK >> GO TO 9.
NG >> Replace intake air temperature sensor.
9. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to EC-1138, "
Component Inspection" .
OK or NG
OK >> GO TO 10.
NG >> Replace EVAP control system pressure sensor.
10. CHECK MASS AIR FLOW SENSOR
Refer to EC-913, "
Component Inspection" .
OK or NG
OK >> GO TO 11.
NG >> Replace mass air flow sensor.
11 . CHECK INTERMITTENT INCIDENT
Refer to EC-857, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END Continuity should exist.
Continuity should exist.
Page 2442 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0101 MAF SENSOR
EC-913
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Component InspectionNBS005CC
MASS AIR FLOW SENSOR
With CONSULT-II
1. Reconnect all harness connectors d INFINITI M35 2007 Factory Service Manual DTC P0101 MAF SENSOR
EC-913
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Component InspectionNBS005CC
MASS AIR FLOW SENSOR
With CONSULT-II
1. Reconnect all harness connectors d](/img/42/57024/w960_57024-2441.png)
DTC P0101 MAF SENSOR
EC-913
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Component InspectionNBS005CC
MASS AIR FLOW SENSOR
With CONSULT-II
1. Reconnect all harness connectors disconnected.
2. Start engine and warm it up to normal operating temperature.
3. Connect CONSULT-II and select “DATA MONITOR” mode.
4. Select “MAS A/F SE-B1” and check indication under the follow-
ing conditions.
*: Check for linear voltage rise in response to engine being increased to about
4,000 rpm.
5. If the voltage is out of specification, proceed the following.
a. Check for the cause of uneven air flow through mass air flow sensor. Refer to following.
Crushed air ducts
Malfunctioning seal of air cleaner element
Uneven dirt of air cleaner element
Improper specification of intake air system parts
b. If NG, repair or replace malfunctioning part and perform step 2 to 4 again.
If OK, go to next step.
6. Turn ignition switch OFF.
7. Disconnect mass air flow sensor harness connector and reconnect it again.
8. Perform step 2 to 4 again.
9. If NG, clean or replace mass air flow sensor.
Without CONSULT-II
1. Reconnect all harness connectors disconnected.
2. Start engine and warm it up to normal operating temperature.
3. Check voltage between ECM terminal 51 (Mass air flow sensor
signal) and ground.
*: Check for linear voltage rise in response to engine being increased to about
4,000 rpm.
4. If the voltage is out of specification, proceed the following.
a. Check for the cause of uneven air flow through mass air flow sensor. Refer to following.
Crushed air ducts
Malfunctioning seal of air cleaner element
Uneven dirt of air cleaner element
Improper specification of intake air system parts
Condition MAS A/F SE-B1 (V)
Ignition switch ON (Engine stopped.) Approx. 0.4
Idle (Engine is warmed-up to normal
operating temperature.)0.9 - 1.2
2,500 rpm (Engine is warmed-up to
normal operating temperature.)1.6 - 1.9
Idle to about 4,000 rpm 0.9 - 1.2 to Approx. 2.4*
PBIB2371E
Condition Voltage V
Ignition switch ON (Engine stopped.) Approx. 0.4
Idle (Engine is warmed-up to normal
operating temperature.)0.9 - 1.2
2,500 rpm (Engine is warmed-up to
normal operating temperature.)1.6 - 1.9
Idle to about 4,000 rpm 0.9 - 1.2 to Approx. 2.4*