INFINITI Q50 HYBRID 2016  Dismantling Guide 4. JUMP STARTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . DG–35
4-1 JUMP STARTING PROCEDURES . . . . . . . . . . . .

Page 18 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide 3-2 Personal Protective Equipment (PPE) and Insulated Tools
3-2.1
Personal Protective Equipment (PPE) Protective Wear Control
Perform an inspection of the Personal Protective Equipment (PPE) items bef

Page 19 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide NOTE:
The
engine must not be running at this time. If the engine has restarted, repeat the previous
steps.
9. Release the parking brake.
10. Unbuckle the seat belt and open the driver door. The READY

Page 20 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide • The vehicle contains parts that contain powerful magnets. If a person who is wearing
a
pacemaker or other medical device is close to these parts, the medical device may be
affected by the magnets.

Page 21 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide Primary Procedure
NO
TE:
Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery i

Page 23 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide NOTE:
If
the electrical release does not work, the trunk will have to be forced open.
6. Open the 12-volt battery service access cover.
7. Disconnect negative (-) battery cable and cover it withinsula

Page 26 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide 8. Open the 12-volt battery service access cover.
9.
Disconnect negative (-) battery cable and cover it with
insulated tape.
10. Wait approximately ten (10) minutes for complete discharge of the high-

Page 27 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide 2. Place the shift selector in the Park (P) position.
3.Push the ignition switch once to turn OFF the high-voltage
system. Then verify whether the READY indicator is off.
If the READY indicator does n

Page 29 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide 6. Open the 12-volt battery service access cover.
7.
Disconnect negative (-) battery cable and cover it with
insulated tape.
8. Open service plug access cover.
9. Remove the service plug (A) by pullin

Page 36 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide 4-1 Jump Starting Procedures
NO
TE:
Jumper cable connections under the hood of the Q50 HYBRID are not connected directly to
a battery. They are connected to chassis ground and a fuse box terminal. Ref