NOTE:
The
engine must not be running at this time. If the engine has restarted, repeat the previous
steps.
9. Release the parking brake.
10. Unbuckle the seat belt and open the driver door. The READY indicator should remain ON
and
the engine should not be running.
11. Turn ON electric devices such as headlamps, A/C (set to the coldest temperature) and rear window defogger to discharge the high-voltage battery. Discharge is complete when the
READY indicator (B) (green) turns OFF, and the hybrid system warning indicator (C)
(orange)
turns ON.
12.
Move shift selector into the Park (P) position and press the ignition switch (A) to turn the system OFF.
Please contact following number if the vehicle could not be discharged. • 1-800-662-6200 (US) or 1-800-361-4792 (Canada)
• Hours of operation are 8am - 5pm (Monday-Friday) Eastern, Central and Pacific time zones.
3-4 How to Handle a Damaged Vehicle
3-4.1 High-voltage System Shut-Down Procedure
Any of the following procedures can shut down the high-voltage system. The dismantling operation can only
begin after shutting down the high-voltage system. If the vehicle is heavily damaged, for example the high-
voltage battery is deformed, broken or cracked, appropriate PPE must always be used and the high-voltage
battery and high-voltage components must not be touched. DANGER
• Failure to properly shut down the high-voltage system before the dismantling
procedures
are performed will result in serious injury or death from electrical shock. To
prevent serious injury or death, NEVER touch high-voltage harnesses or components
without always wearing appropriate Personal Protective Equipment (PPE) . PPE
must always be worn when touching or working on high-voltage components.
•
When contact with high-voltage components or high-voltage harnesses is
unavoidable, or when there is risk of such contact, you must always wear appropriate
PPE. PPE must always be worn when touching or working on high-voltage components. A B
CLOCK
ACC
(OFF)
ON
AAYIA0078GB
DG–19
Page 20 of 54

• The vehicle contains parts that contain powerful magnets. If a person who is wearing
a
pacemaker or other medical device is close to these parts, the medical device may be
affected by the magnets. Such persons must not perform work on the vehicle.
• Be sure to verify that the READY indicator is off (if possible) , and the high-voltage
system
is stopped.
• After the high-voltage system is shut down, please wait approximately ten (10) minutes for complete discharge of the high-voltage capacitor. While waiting, do not operate any
vehicle functions.
• After shutting down the high-voltage system and removing the 12-volt battery negative (-) terminal, wait at least three (3) minutes to discharge the air bag capacitor. Even though
the 12-volt battery negative (-) is disconnected, the Supplemental Restraint System (SRS)
air bag maintains voltage at least three (3) minutes. During this time, there is a possibility
of sudden SRS air bag inflation due to harness short circuit or damage and it may cause
serious injuries.
• The 12V system will remain active even after the 12-volt battery negative (-) terminal is removed while the high-voltage system is active. This is because the charging system
will not shut down and power will be supplied to the 12V system and high-voltage system
continuously.
Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust the steering
column, adjust the seats, unlock the doors, open the trunk, etc. as required. Once the 12-volt battery is
disconnected, power controls will not operate.
Powering Down the High-voltage System
The high-voltage system can be shut down with any 1 of the following procedures: • Turn OFF the power switch and disconnect the 12-volt battery. Refer to Primary Procedure
(DG–21) .
•
Remove the fuse for the high-voltage control system and disconnect the 12-volt battery. Refer to
Alternate Procedure 1 (Disconnect Underhood Fuse Panel) (DG–23).
•
Remove the service plug and disconnect the 12-volt battery. Refer to Alternate Procedure 2
(Remove
Service Plug) (DG–26) .
DG–20
Page 21 of 54

Primary Procedure
NO
TE:
Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate.
1. If possible, check the READY indicator status in the instrument cluster. If it is on, the high-
voltage
system is active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch once to turn OFF the high- voltage system. Verify that the READY indicator is off
and then continue to the next steps to open the trunk for
12-volt battery negative cable access.
If the READY indicator does not turn off, refer to
Alternate Procedure 1 (Disconnect Underhood Fuse
Panel)
(DG–23)
4. If possible, keep the Infiniti Intelligent Key at least 5
meters (16 feet) away from the vehicle (except to
open the trunk as noted below) . AAYIA0191ZZ
LOCK
ACC
(OFF)
ON
AAYIA0192ZZ
AAYIA0068ZZ
DG–21
Page 23 of 54

NOTE:
If
the electrical release does not work, the trunk will have to be forced open.
6. Open the 12-volt battery service access cover.
7. Disconnect negative (-) battery cable and cover it withinsulated tape.
8. Wait approximately ten (10) minutes for complete discharge of the high-voltage capacitor
after the battery cable has been disconnected.
9. Perform the dismantling operation. Refer to 6. Dismantling Information (DG–40).
Alternate
Procedure 1 (Disconnect Underhood Fuse Panel)
NOTE:
Before disconnecting the underhood fuse panel and the negative (-) battery cable, if
necessary, lower the windows, adjust the steering column, adjust the seats, unlock the
doors, etc. Once the underhood fuse panel and negative (-) battery cable are disconnected,
power controls will not operate. 1. Pull release handle (1) and pull up release lever (2) to open the hood. AAYIA0195ZZ
AAYIA0196ZZ
AAYIA0205ZZ
DG–23
Page 26 of 54

8. Open the 12-volt battery service access cover.
9.
Disconnect negative (-) battery cable and cover it with
insulated tape.
10. Wait approximately ten (10) minutes for complete discharge of the high-voltage capacitor
after the fuse panel and battery cable have been disconnected.
11. Perform the dismantling operation. Refer to 6. Dismantling Information (DG–40).
Alternate
Procedure 2 (Remove Service Plug) DANGER
• Do not remove the service plug without always wearing appropriate Personal
Protective
Equipment (PPE) to help protect the dismantler from serious injury or death
by electrical shock.
• Immediately cover the service plug socket with insulated tape. The high-voltage
battery
retains high-voltage power even when the service plug is removed. To avoid
electric shock, NEVER touch the terminals inside the socket. To avoid unintended reinstallation and risk of electrical shock and severe personal injury
or
death, the dismantler should carry the service plug on his/her person while work is in
progress.
NOTE: Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate. 1. If possible, check the READY indicator status in the instrument cluster. If it is on, the high-
voltage
system is active. AAYIA0195ZZ
AAYIA0196ZZ
DG–26