This
manual describes dismantling operations and important safetyrelated warnings and cautions for this
vehicle.
This vehicle is equipped with a high-voltage battery pack. Failure to follow r

Page 3 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide Table of Contents
FOREWORD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DG–2
INFINITI EMERGENCY CONTACT INF

Page 4 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide 4. JUMP STARTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . DG–36
4-1 JUMP STARTING PROCEDURES . . . . . . . . . . . .

Page 5 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide 1. About the INFINITI Q50 HYBRID
This
hybrid electric vehicle (HEV) uses two types of batteries. One is a 12-volt battery that is the same as
the battery in vehicles powered by internal combustion eng

Page 10 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide 2. Basic High-voltage Information
2-1
Battery Information
The Q50 HYBRID utilizes two batteries in order to supply both high and low voltage.
2-1.1 12-Volt Battery • The Q50 HYBRID contains a conven

Page 12 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide No. Component
LocationDescription
� T
raction Motor
Inverter
Engine compartment
(right rear side)Converts the DC power stored in the high-
voltage battery to three-phase AC power and
controls motor to

Page 13 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide 2-4 High-voltage Safety Measures
Circuit insulation
The high-voltage positive (+) and negative (-) circuits are insulated
from the metal chassis.
Reducing the risk of electrocution The high-voltage co

Page 14 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide 2-5 High-voltage Safety System
The
high-voltage safety system is intended to help keep vehicle occupants and emergency responders safe
from high-voltage electricity. • A high-voltage fuse provides s

Page 15 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide • The high-voltage system and high-voltage capacitor may remain powered for up to
approximately 10 minutes after the vehicle is shut off. Personal Protective Equipment
(PPE) must always be worn when

Page 16 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide 3. Preparation for Dismantling
DANGER
• Failure to properly shut down the high-voltage electrical system before the
Dismantling Procedures are performed will result in serious injury or death from
e