cooling INFINITI QX60 HYBRID 2015 Dismantling Guide
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2015, Model line: QX60 HYBRID, Model: INFINITI QX60 HYBRID 2015Pages: 49, PDF Size: 3.21 MB
Page 10 of 49

2. Basic High Voltage Information
2-1 Battery Information
The QX60 HYBRID utilizes two batteries in order to supply both high and low voltage.
2-1.1 12-Volt Battery• The QX60 HYBRID contains a conventional lead-acid12-volt battery.
• The 12-volt battery is located in the front of the vehicle on the left side of the engine compartment.
• The 12-volt battery is charged by the high voltage battery through the DC/DC converter.
: Vehicle front
2-1.2 High Voltage Battery • The QX60 HYBRID contains a high voltage battery.
• The high voltage battery is mounted in the cargo areaunder the 3rd row seating, enclosed in a metal case
and concealed by trim cover.
•
The high voltage battery stores approximately 144 volts DC.
• A vent hose is provided to exhaust gasses outside the vehicle if necessary.
• Air vents (A) are located on the cargo area trim panels for battery cooling.
The high voltage battery supplies power to the following: • High voltage harnesses
• DC/DC converter
• Traction motor inverter
• Traction motor
AAYIA0300ZZ
AAYIA0301ZZ
AA
AAYIA0264ZZ
DG–10
Page 34 of 49

4. Jump Starting
To start the hybrid system with a booster battery, the instructions and precautions below must be followed.
If done incorrectly, jump starting can lead to a 12-volt battery explosion, resulting in severe
personal injury or death. It could also damage your vehicle.
Jump starting provides power to the 12-volt system to allow the electrical systems to operate. The electrical
systems must be operating to allow the high voltage battery to be charged. Jump starting does not charge
the high voltage battery.
Discharged 12-volt battery may cause the following issues: • The instrument cluster cannot be displayed while the ignition switch is turned ON. (The hybridsystem cannot start.)
• Headlamps, horn, etc. are weak.
•To avoid electrical shock, the high voltage battery CANNOT be jump started.
• Explosive hydrogen gas is always present in the vicinity of the 12-volt battery. Keep all sparks and flames away from the 12-volt battery. Make sure the vent tube is mounted.
• Do not allow battery fluid to come into contact with eyes, skin, clothing or painted surfaces. Battery fluid is a corrosive sulfuric acid solution that can cause severe burns.
If the fluid comes into contact with anything, immediately flush the contacted area
with water.
• The booster battery must be rated at 12 volts. Use of an improperly rated battery can damage the vehicle.
• Whenever working on or near a 12-volt battery, always wear suitable eye protectors (for example, goggles or industrial safety spectacles) and remove rings, metal bands, or
any other jewelry. Do not lean over the 12-volt battery when jump starting.
• Do not attempt to jump start a frozen battery. It could explode and cause serious injury.
• QX60 HYBRID is equipped with an automatic cooling fan. It could come on at any time. Keep hands and other objects away from it.
• Always follow the jump starting instructions below. Failure to do so could result in damage to the charging system and cause personal injury.
DG–34
Page 42 of 49

Rear Ducts Exploded View1. Rear ventilator duct 1 2. Rear ventilator duct 2 3. Rear ventilator duct 3
4. Rear ventilator duct lower 5. Rear cooling unit assembly 6. Rear ventilator duct upper
1
2
3
4
5
6
AAYIA0310ZZ