hood release INFINITI QX60 HYBRID 2015 Dismantling Guide
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2015, Model line: QX60 HYBRID, Model: INFINITI QX60 HYBRID 2015Pages: 49, PDF Size: 3.21 MB
Page 7 of 49
1-1.2 Interior
Interior components referenced in this manual are as follows:A. Assist charge gauge B. READY indicator (green) C. Energy flow display *1
D. Energy flow display *1 E. Liftgate switch F. Hood release handle
G. START/STOP switch and
ON indicator lamp (orange)
*1: This screen may not be displayed due to customer settings. Only one of these screens will display
energy flow depending on vehicle optional equipment.
A
GFE
BCD
AAYIA0261ZZ
DG–7
Page 22 of 49
5. Pull release handle (1) and pull up release lever (2) to open hood.
6. Remove traction motor inverter cover (1) .
7. Disconnect negative (-) battery cable and cover it withinsulated tape.
8. Wait approximately ten (10) minutes for complete discharge of the high voltage capacitor
after the battery cable has been disconnected.
9. Perform the dismantling operation. Refer to
6. Dismantling Information (DG–39).
1
2
AAYIA0272ZZ
1
AAYIA0273ZZ
AAYIA0274ZZ
DG–22
Page 23 of 49
Alternate Procedure 1 (Remove Fuses)
NOTE:Before removing any fuses, if necessary, lower the windows, adjust the steering column,
adjust the seats, unlock the doors, etc. Once fuses are removed, power controls will notoperate. 1. Pull release handle (1) and pull up release lever (2) to open the hood.
2. Release clips (A) and remove fuse box cover (1) .
: Vehicle front
3. Remove IGCT RLY fuse (F/L V IGCT RLY 50A) .
4. If you cannot identify the correct fuse, remove all the fuses.
To avoid unintended reinstallation and risk of
electrical shock and severe personal injury or death,
the dismantler should carry the fuse or fuses on his/her
person and cover the fuse box with insulated tape.
1
2
AAYIA0272ZZ
1
A
AAYIA0303ZZ
F/L V IGCT RLY 50A (Red)
AAYIA0071GB
DG–23
Page 28 of 49
8. Remove the service plug (A) by pulling the locking lever (B) , then pressing the locking tab (C)and rotating the handle (D) fully outward. Using the handle, pull the service plug (E) completely
out of its socket.
9. Cover the service plug socket with insulated tape.
10. Wait approximately ten (10) minutes for complete discharge of the high voltage capacitor
after the service plug has been removed.
11. Pull release handle (1) and pull up release lever (2) to open hood.
12. Remove traction motor inverter cover (1) .
A
B
C
DE
AAYIA0202ZZ
1
2
AAYIA0272ZZ
1
AAYIA0273ZZ
DG–28