jump start MAZDA MODEL MX-5 RF 2017 Owners Manual (in English)
[x] Cancel search | Manufacturer: MAZDA, Model Year: 2017, Model line: MODEL MX-5 RF, Model: MAZDA MODEL MX-5 RF 2017Pages: 609, PDF Size: 5.96 MB
Page 495 of 609

7–1*Some models.7–1
7If Trouble Arises
Helpful information on what to do if a problem arises with the vehicle.
Parking in an Emergency ................... 7-2
Parking in an Emergency ............... 7-2
Roadside Emergency Triangle
Retaining Strap
* ............................. 7-2
Flat Tyre ............................................... 7-3
Flat Tyre
* ........................................ 7-3
Tool Storage ................................... 7-5
Emergency Flat Tyre Repair
Kit
* ................................................. 7-7
Changing a Tyre ........................... 7-14
Battery Runs Out .............................. 7-20
Jump-Starting ............................... 7-20
Emergency Starting .......................... 7-23
Starting a Flooded Engine ............ 7-23
Push-Starting ................................ 7-23
Overheating ....................................... 7-24
Overheating .................................. 7-24
When Fuel-Filler Flap Cannot be
Opened ............................................... 7-26
When Fuel-Filler Flap Cannot be
Opened ......................................... 7-26
Emergency Towing ............................ 7-27
Towing Description ...................... 7-27
Towing Hooks .............................. 7-28 Warning/Indicator Lights and Warning
Sounds ................................................ 7-31
If a Warning Light Turns On or
Flashes .......................................... 7-31
Message Indicated in Multi-
information Display
* .................... 7-46
Message Indicated on Display * .... 7-47
Warning Sound is Activated ......... 7-49
When Boot Lid Cannot be
Opened ............................................... 7-55
When Boot Lid Cannot be
Opened ......................................... 7-55
When the Roof Cannot be Closed.... 7-60
When the Roof Cannot be
Closed .......................................... 7-60
/ : A ( . ' ' , A ' F K V K Q P K P F D
Page 514 of 609

7–20
If Trouble Arises
Battery Runs Out
J u m p - S t a r t i n g
Jump-starting is dangerous if done incorrectly. So follow the procedure carefully. If you
feel unsure about jump-starting, we strongly recommend that you have a competent service
technician do the work.
WARNING
Follow These Precautions Carefully:
To ensure safe and correct handling of the battery, read the following precautions
carefully before using the battery or inspecting it.
Do not allow the positive ( ) terminal to contact any other metal object that
could cause sparks:
Flames and sparks near open battery cells are dangerous. Hydrogen gas, produced
during normal battery operation, could ignite and cause the battery to explode. An
exploding battery can cause serious burns and injuries. When working near a battery,
do not allow metal tools to contact the positive (
) or negative ( ) terminal of the
battery.
Keep all À ames, including cigarettes, and sparks away from open battery cells:
Flames and sparks near open battery cells are dangerous. Hydrogen gas, produced
during normal battery operation, could ignite and cause the battery to explode. An
exploding battery can cause serious burns and injuries.
Do not jump-start a frozen battery or one with a low À uid level:
Jump-starting a frozen battery or one with a low À uid level is dangerous. It may rupture
or explode, causing serious injury.
Connect the negative lead to a good ground point away from the battery:
Connecting the end of the second jumper lead to the negative (
) terminal of the
discharged battery is dangerous.
A spark could cause the gas around the battery to explode and injure someone.
Route the jumper leads away from parts that will be moving:
Connecting a jumper lead near or to moving parts (cooling fans, belts) is dangerous.
The lead could get caught when the engine starts and cause serious injury.
/ : A ( . ' ' , A ' F K V K Q P K P F D
Page 515 of 609

7–21
If Trouble Arises
Battery Runs Out
CAUTION
Use only a 12 V booster system. You can damage a 12 V starter, ignition system, and other
electrical parts beyond repair with a 24 V power supply (two 12 V batteries in series or a
24 V motor generator set).
Jumper leads
Booster batteryDischarged battery
/ : A ( . ' ' , A ' F K V K Q P K P F D
Page 516 of 609

7–22
If Trouble Arises
Battery Runs Out
1. Remove the battery cover.
2. Make sure the booster battery is 12
V and that its negative terminal is
grounded.
3. If the booster battery is in another
vehicle, do not allow both vehicles
to touch. Turn off the engine of the
vehicle with the booster battery and
all unnecessary electrical loads in both
vehicles.
4. Connect the jumper leads in the exact
sequence as in the illustration.
Connect one end of a lead to the
positive terminal on the discharged
battery (1).
Attach the other end to the positive
terminal on the booster battery (2).
Connect one end of the other lead to
the negative terminal of the booster
battery (3).
Connect the other end to the ground
point indicated in the illustration
away from the discharged battery (4).
5. Start the engine of the booster vehicle
and run it a few minutes. Then start the
engine of the other vehicle.
6. When ¿ nished, carefully disconnect the
leads in the reverse order described in
the illustration. 7. If the battery cover has been removed,
install it in the reverse order of
removal.
NOTE
Verify that the covers are securely
installed.