5. CHECK MOTOR GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect each door motor connector.
3. Check continuity between each door motor harness connector
terminal 2 and ground.
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.
6. CHECK MOTOR OPERATION
1. Reconnect each door motor connector.
2. Turn ignition switch ON.
3. Confirm operation of each door motor.
OK or NG
OK >> Return to operate normally.
Poor contact in motor connector
NG >> Does not operate normally.
GO TO 7.
7. CHECK AIR MIX DOOR MOTOR AND INTAKE DOOR MOTOR OPERATION
1. Turn ignition switch OFF.
2. Disconnect mode door motor, air mix door motor and intake door motor connector.
3. Reconnect air mix door motor and intake door motor connector.
4. Turn ignition switch ON.
5. Confirm operation of air mix door motor and intake door motor.
OK or NG
OK >> Air mix door motor and intake door motor operate normally.
Replace mode door motor.
NG >> Air mix door motor and intake door motor does not operate normally.
GO TO 8.
8. CHECK MODE DOOR MOTOR AND INTAKE DOOR MOTOR OPERATION
1. Turn ignition switch OFF.
2. Disconnect air mix door motor connector.
3. Reconnect mode door motor connector.
4. Turn ignition switch ON.
5. Confirm operation of mode door motor and intake door motor.
OK or NG
OK >> Mode door motor and intake door motor operate normally.
Replace air mix door motor.
NG >> Mode door motor and intake door motor does not operate normally.
GO TO 9. 2 – Ground : Continuity should exist.
RJIA1990E
Page 59 of 142

TROUBLE DIAGNOSIS
ATC-59
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 November2007 350Z
9. CHECK MODE DOOR MOTOR AND AIR MIX DOOR MOTOR OPERATION
1. Turn ignition switch OFF.
2. Disconnect intake door motor connector.
3. Reconnect air mix door motor connector.
4. Turn ignition switch ON.
5. Confirm operation of mode door motor and air mix door motor.
OK or NG
OK >> Mode door motor and air mix door motor operate normally.
Replace intake door motor.
NG >> Mode door motor and air mix door motor does not operate normally.
Replace unified meter and A/C amp.
Page 72 of 142

ATC-72
TROUBLE DIAGNOSIS
Revision: 2006 November2007 350Z
1. CHECK POWER SUPPLY FOR BLOWER MOTOR
1. Disconnect blower motor connector.
2. Turn ignition switch ON.
3. Check voltage between blower motor harness connector M62
terminal 1 and ground.
OK or NG
OK >> GO TO 2.
NG >> Check power supply circuit and 15A fuses [Nos. 10 and
11, located in the fuse block (J/B)]. Refer to PG-85,
"FUSE BLOCK - JUNCTION BOX (J/B)" .
If fuse are OK, check harness for open circuit. Repair or replace if necessary.
If fuse are NG, check harness for short circuit and replace fuse.
2. CHECK GROUND CIRCUIT FOR BLOWER MOTOR
1. Turn ignition switch OFF.
2. Check continuity between blower motor harness connector M62
terminal 3 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connector.
3. CHECK CIRCUIT CONTINUITY BETWEEN BLOWER MOTOR AND UNIFIED METER AND A/C AMP.
1. Disconnect unified meter connector and A/C amp. connector.
2. Check continuity between blower motor harness connector M62
terminal 2 and unified meter and A/C amp. harness connector
M50 terminal 53.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.1 – Ground : Battery voltage
RJIA1997E
3 – Ground : Continuity should exist.
RJIA1998E
2 – 53 : Continuity should exist.
RJIA1999E
Page 73 of 142

TROUBLE DIAGNOSIS
ATC-73
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 November2007 350Z
4. CHECK UNIFIED METER AND A/C AMP. OUTPUT SIGNAL
1. Reconnect blower motor connector and unified meter and A/C
amp. connector.
2. Turn ignition switch ON.
3. Change the fan speed from Lo to Hi, and check the duty ratios
between blower motor harness connector M62 terminal 2 and
ground by using an oscilloscope. Normal terminal 2 drive signal
duty ratios are shown in the table below.
OK or NG
OK >> Replace blower motor after confirming the fan air flow does not change.
NG >> Replace unified meter and A/C amp.
COMPONENT INSPECTION
Blower Motor
Confirm smooth rotation of the blower motor.
Ensure that there are no foreign particles inside the blower unit.
RJIA2000E
RJIA1390E
RJIA0905E
Page 76 of 142

ATC-76
TROUBLE DIAGNOSIS
Revision: 2006 November2007 350Z
1. CHECK AMBIENT SENSOR CIRCUIT AND INTAKE SENSOR CIRCUIT
Check ambient sensor and intake sensor. Refer to AT C - 4 6 , "
FUNCTION CONFIRMATION PROCEDURE" ,
see No. 9.
OK or NG
OK >> GO TO 2.
NG >>
Malfunctioning ambient sensor: Refer to AT C - 9 2 , "Ambient Sensor Circuit" .
Malfunctioning intake sensor: Refer to ATC-100, "Intake Sensor Circuit" .
2. PERFORM AUTO ACTIVE TEST
Refer to PG-20, "
Auto Active Test" .
Dose the magnet clutch operate?
YES >> WITH CONSULT-III: GO TO 5.
WITHOUT CONSULT-III: GO TO 6.
NO >> Check 10A fuse (No. 79, located in IPDM E/R), and GO TO 3. Refer to PG-23, "
IPDM E/R Termi-
nal Arrangement" .
3. CHECK CIRCUIT CONTINUITY BETWEEN IPDM E/R AND COMPRESSOR
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and compressor connector.
3. Check continuity between IPDM E/R harness connector E8 ter-
minal 33 and compressor harness connector F24 terminal 1.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.
4. CHECK MAGNET CLUTCH CIRCUIT
Check for operation sound when applying battery voltage direct cur-
rent to terminal.
OK or NG
OK >> 1. Replace IPDM E/R.
2. Go to self-diagnosis procedure AT C - 4 6 , "
FUNCTION
CONFIRMATION PROCEDURE" and preform self-
diagnosis STEP-4. Confirm that magnet clutch opera-
tion normal.
NG >> 1. Replace magnet clutch.
2. Go to self-diagnosis procedure AT C - 4 6 , "
FUNCTION
CONFIRMATION PROCEDURE" and preform self-
diagnosis STEP-4. Confirm that magnet clutch operation normal.
5. CHECK BCM INPUT (COMPRESSOR ON) SIGNAL
Check compressor ON/OFF signal. Refer to AT C - 3 3 , "
CONSULT-III Function (BCM)" .
OK or NG
OK >> GO TO 8.
NG >> GO TO 6.
33 – 1 : Continuity should exist.
RJIA2004E
RJIA2005E
A/C SW ON : AIR COND SIG ON
A/C SW OFF : AIR COND SIG OFF
Page 77 of 142

TROUBLE DIAGNOSIS
ATC-77
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 November2007 350Z
6. CHECK CIRCUIT CONTINUITY BETWEEN BCM AND UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Disconnect BCM connector and unified meter and A/C amp.
connector.
3. Check continuity between BCM harness connector M90 terminal
27 and unified meter and A/C amp. harness connector M50 ter-
minal 42.
OK or NG
OK >> GO TO 7.
NG >> Repair harness or connector.
7. CHECK VOLTAGE FOR UNIFIED METER AND A/C AMP. (COMPRESSOR ON SIGNAL)
1. Reconnect BCM connector and unified meter and A/C amp.
connector.
2. Turn ignition switch ON.
3. Check voltage between unified meter and A/C amp. harness
connector M50 terminal 42 and ground.
OK or NG
OK >> GO TO 8.
NG-1 >> If the voltage is approx. 5 V when A/C switch is ON: Replace unified meter and A/C amp.
NG-2 >> If the voltage is approx. 0 V when A/C switch is OFF: Replace BCM.27 – 42 : Continuity should exist.
RJIA2006E
Terminals
Condition Voltage (+)
(−) Unified meter
and A/C amp.
connectorTerminal No.
M50 42 GroundA/C switch: ON
(Blower motor oper-
ates.)Approx. 0 V
A/C switch: OFF Approx. 5 V
RJIA2007E
Page 78 of 142

ATC-78
TROUBLE DIAGNOSIS
Revision: 2006 November2007 350Z
8. CHECK REFRIGERANT PRESSURE SENSOR
WITH CONSULT-III
1. Start the engine.
2. Check voltage of refrigerant pressure sensor. Refer to EC-127, "
CONSULT-III Reference Value in Data
Monitor" .
WITHOUT CONSULT-III
1. Start the engine.
2. Check voltage between ECM harness connector M71 terminal 105 and ground.
OK or NG
OK >> WITH CONSULT-III: GO TO 9.
WITHOUT CONSULT-III: GO TO 10.
NG >> Refer to EC-710, "
REFRIGERANT PRESSURE SENSOR" .
9. CHECK BCM INPUT (FAN ON) SIGNAL
Check FAN ON/OFF signal. Refer to AT C - 3 3 , "
CONSULT-III Function (BCM)" .
OK or NG
OK >> GO TO 12.
NG >> GO TO 10.
10. CHECK CIRCUIT CONTINUITY BETWEEN BCM AND UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Disconnect BCM connector and unified meter and A/C amp.
connector.
3. Check continuity between BCM harness connector M90 terminal
28 and unified meter and A/C amp. harness connector M50 ter-
minal 57.
OK or NG
OK >> GO TO 11.
NG >> Repair harness or connector.
Terminals
Condition Voltage (+)
(−)
ECM con-
nectorTerminal No.
M71 105 GroundA/C switch: ON
(Blower motor
operates.)Approx. 1.0 - 4.0 V
FAN SW ON : HEATER FAN SW ON
FAN SW OFF : HEATER FAN SW OFF
28 – 57 : Continuity should exist.
RJIA2009E
Page 79 of 142

TROUBLE DIAGNOSIS
ATC-79
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 November2007 350Z
11 . CHECK VOLTAGE FOR UNIFIED METER AND A/C AMP. (FAN ON SIGNAL)
1. Reconnect BCM connector and unified meter and A/C amp.
connector.
2. Turn ignition switch ON.
3. Check voltage between unified meter and A/C amp. harness
connector M50 terminal 57 and ground.
OK or NG
OK >> GO TO 12.
NG-1 >> If the voltage is approx. 5 V when blower motor is ON: Replace unified meter and A/C amp.
NG-2 >> If the voltage is approx. 0 V when blower motor is OFF: Replace BCM.
12. CHECK CAN COMMUNICATION
Check CAN communication. Refer to BCS-16, "
CAN Communication Inspection Using CONSULT-III (Self-
Diagnosis)" .
BCM – ECM
ECM – IPDM E/R
ECM – Unified meter and A/C amp.
OK or NG
OK >> Replace ECM.
NG >> Repair or replace malfunctioning part(s).
Terminals
Condition Voltage (+)
(−) Unified meter
and A/C amp.
connectorTerminal No.
M50 57 GroundFan control dial: ON
(Blower motor oper-
ates.)Approx. 0 V
Fan control dial: OFF Approx. 5 V
RJIA2010E
Page 92 of 142

ATC-92
TROUBLE DIAGNOSIS
Revision: 2006 November2007 350Z
Ambient Sensor CircuitNJS0001A
COMPONENT DESCRIPTION
Ambient Sensor
The ambient sensor is attached on the hood lock stay. It detects
ambient temperature and converts it into a resistance value which is
then input into the unified meter and A/C amp.
AMBIENT TEMPERATURE INPUT PROCESS
The unified meter and A/C amp. includes a processing circuit for the ambient sensor input. However, when the
temperature detected by the ambient sensor increases quickly, the processing circuit retards the unified meter
and A/C amp. function. It only allows the unified meter and A/C amp. to recognize an ambient temperature
increase of 0.33°C (0.6°F) per 100 seconds.
As an example, consider stopping for a few minutes after high speed driving. Although the actual ambient tem-
perature has not changed, the temperature detected by the ambient sensor will increase. This is because the
heat from the engine compartment can radiate to the front bumper area, location of the ambient sensor.
DIAGNOSIS PROCEDURE FOR AMBIENT SENSOR
SYMPTOM: Ambient sensor circuit is open or shorted. (LED of A/C
switch does not illuminate as a result of performing self-diagnosis
STEP-2.)
1. CHECK VOLTAGE BETWEEN AMBIENT SENSOR AND GROUND
1. Disconnect ambient sensor connector.
2. Turn ignition switch ON.
3. Check voltage between ambient sensor harness connector E34
terminal 1 and ground.
OK or NG
OK >> GO TO 2.
NG >> GO TO 4.
RJIA1398E
RJIA1461E
1 – Ground : Approx. 5 V
RJIA2017E
Page 93 of 142

TROUBLE DIAGNOSIS
ATC-93
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 November2007 350Z
2. CHECK CIRCUIT CONTINUITY BETWEEN AMBIENT SENSOR AND UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Disconnect unified meter and A/C amp. connector.
3. Check continuity between ambient sensor harness connector
E34 terminal 2 and unified meter and A/C amp. harness connec-
tor M50 terminal 49.
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connector.
3. CHECK AMBIENT SENSOR
Refer to AT C - 9 4 , "
Ambient Sensor" .
OK or NG
OK >> 1. Replace unified meter and A/C amp.
2. Go to self-diagnosis AT C - 4 6 , "
FUNCTION CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-2.
NG >> 1. Replace ambient sensor.
2. Go to self-diagnosis AT C - 4 6 , "
FUNCTION CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-2.
4. CHECK CIRCUIT CONTINUITY BETWEEN AMBIENT SENSOR AND UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Disconnect unified meter and A/C amp. connector.
3. Check continuity between ambient sensor harness connector
E34 terminal 1 and unified meter and A/C amp. harness connec-
tor M50 terminal 39.
4. Check continuity between ambient sensor harness connector
E34 terminal 1 and ground.
OK or NG
OK >> 1. Replace unified meter and A/C amp.
2. Go to self-diagnosis AT C - 4 6 , "
FUNCTION CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-2.
NG >> Repair harness or connector.2 – 49 : Continuity should exist.
RJIA2018E
1 – 39 : Continuity should exist.
1 – Ground : Continuity should not exist.
RJIA2019E