instrument cluster NISSAN MURANO HYBRID 2016 3.G First Responders Guide
[x] Cancel search | Manufacturer: NISSAN, Model Year: 2016, Model line: MURANO HYBRID, Model: NISSAN MURANO HYBRID 2016 3.GPages: 44, PDF Size: 5.13 MB
Page 9 of 44
1-3 Warning and Indicator Lamp Information
1. Hybrid System Warning Lamp
(Orange) 2. Master Warning Lamp
(Orange or Red)3. READY Indicator (Green)Lamp Name
Icon Description
READ
Y Indicator
(Green) This lamp is on when the high-voltage system is powered
up
and the vehicle is ready to drive.
Master Warning Lamp
(Orange or Red) This lamp is on when another warning lamp or message is
displayed
in the instrument cluster.
Hybrid System
Warning Lamp *1
(Orange) This lamp is on or blinking when:
•
Malfunction has occurred in the hybrid control system
and/or
• High-voltage leak to vehicle chassis and/or
• Emergency shut-off system has been activated. The shut-off system activates in the following conditions:
– Front and side collisions in which the air bags are deployed.
– Certain rear collisions.
– Certain high-voltage system malfunctions.
*1: When this lamp is ON, the READY Indicator will turn OFF. 1
0
2
3
4
5
6
7
8
PWR km/h
MPH
RPMx1000 20
0 0
0
20
40
60
80
180
200
220
240
260
100
160
120 140
1
2
40
60
80
100
120
140
160 1 2 3
AAYIA0426ZZ
FRG–9
Page 15 of 44
• The high-voltage system and high-voltage capacitor may remain powered for up to
approximately 10 minutes after the vehicle is shut off. Appropriate Personal Protective
Equipment (PPE) must always be worn when touching or working on high-voltage
components to avoid risk of electrical shock and severe personal injury or death.
• The high-voltage battery retains high-voltage at all times. Appropriate PPE must always be worn when touching or working on high-voltage components to avoid risk of electrical
shock and severe personal injury or death.
• A ground fault monitor continuously monitors for high-voltage leakage to the metal chassis while the vehicle is running. If a malfunction is detected, the HPCM (hybrid powertrain control module) will
illuminate the hybrid system warning lamp in the instrument cluster.
•
The high-voltage battery relays (SMR1 and SMR2) will automatically open to stop the electrical flow
in a front, side or certain rear collisions that are sufficient enough to activate the supplemental
restraint system (SRS) . Passenger Compartment
J
unction Box High-voltage Battery
System main relay 1
Service Plug (With Fuse)
System main relay 2
Transmission
Traction Motor Traction
Motor Inverter
(With built in high- voltage capacitor) DC/DC
Converter
HPCM
(Hybrid Powertrain Control Module)
Engine Compartment AAYIA0136GB
FRG–15
Page 17 of 44
3. Emergency Response Steps
DANGER
• Failure to properly shut down the high-voltage electrical system before the
Emergency Response Procedures are performed will result in serious injury or death
from electrical shock. To prevent serious injury or death, NEVER touch high-voltage
harnesses or components without always wearing appropriate Personal Protective
Equipment (PPE) . PPE must always be worn when touching or working on high-
voltage components.
• If it is necessary to touch any of the high-voltage harnesses or components you
must
always wear appropriate PPE to avoid electrical shock. PPE must always be worn
when touching or working on high-voltage components. Shut down the high-voltage
system by following the steps outlined in 3-3.1 High-voltage System Shut-Down
Procedure
(FRG–22) . Wait approximately ten (10) minutes for complete discharge of
the
high-voltage capacitor after the high-voltage system has been shut down. • NEVER assume the Murano HYBRID is shut OFF simply because it is quiet.
•
If the READY indicator is ON the high-voltage system is active.
•
If possible, be sure to check the READY indicator on the instrument cluster and
verify
that the READY indicator is OFF and the high-voltage system is stopped.
FRG–17
Page 23 of 44
Powering Down the High-voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the ignition switch and disconnect the 12-volt battery. Refer to Primary Procedure
(FRG–23) .
•
Remove the underhood fuse for the high-voltage control system and disconnect the 12-volt battery.
Refer to Alternate Procedure 1 (Remove Fuses) (FRG–25).
•
Remove the service plug and disconnect the 12-volt battery. Refer to Alternate Procedure 2
(Remove
Service Plug) (FRG–27) .
Primary
Procedure
NOTE:
Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate.
1. If possible, check the READY indicator status in the instrument cluster. If it is on,
the
high-voltage system is active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch once to turn OFF the high- voltage system. Verify that the READY indicator is off
and then continue to the next steps to open the hood
for 12-volt battery negative cable access.
If the READY indicator does not turn off, refer to
Alternate Procedure 1 (Remove Fuses) (FRG–25).
4.
If possible, keep the Nissan Intelligent Key® at least
5 meters (16 feet) away from the vehicle.P R N
D ACC
ENGINESTART
STOP LOCK
(OFF)
ON
AAYIA0137GB
HOLD AAYIA0446ZZ
FRG–23
Page 27 of 44
Alternate Procedure 2 (Remove Service Plug)
DANGER
• Do not remove the service plug without always wearing appropriate Personal
Protective Equipment (PPE) to help protect the responder from serious injury or death
by electrical shock.
• Immediately cover the service plug socket with insulated tape. The high-voltage
battery
retains high-voltage power even when the service plug is removed. To avoid
electric shock, NEVER touch the terminals inside the socket. To avoid unintended reinstallation and risk of electrical shock and severe personal
injury
or death, the rescuer should carry the service plug on his/her person while work is
in progress.
NOTE: Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate.
1. If possible, check the READY indicator status in the instrument cluster. If it is on,
the
high-voltage system is active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch once to turn OFF the high- voltage system. Then verify whether the READY
indicator is off.
If the READY indicator does not turn off, continue to
step 4.
4. If possible, keep the Nissan Intelligent Key® at least 5 meters (16 feet) away from the vehicle.
PR N
D ACC
ENGINESTART
STOP LOCK
(OFF)
ON
AAYIA0137GB
HOLD AAYIA0446ZZ
FRG–27