heating RENAULT SCENIC 2010 J95 / 3.G Air Conditioning User Guide
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2010, Model line: SCENIC, Model: RENAULT SCENIC 2010 J95 / 3.GPages: 60
Page 25 of 60

62A - 25
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating (continued 3)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
InjectionET024:Set number of
RCH.NO
NOTE: According to the
injection's requirements:
power requirement, torque
reduction, etc., the injection
computer sets the number
of RCH stages switched on
(no more, no less).If there is a fault, refer to the
fault finding procedure
for this status.
PR064:Coolant
temperature.X = engine coolant
temperature.If there is a fault, refer to the
fault finding procedure
for this parameter.
Protection and
Switching UnitPR002:Alternator charge
signal99 %, engine stopped.If there is a fault, refer to the
fault finding procedure
for this parameter.
AC011:Heated rear
screen.Command for testing the
operation of the rear screen
heating.If there is a fault, consult the
fault finding procedure
for this command.
NOTE: The UPC cannot
test the heated rear screen
control circuit; this
command is the only way to
test its operation.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif
Page 35 of 60

62A - 35
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating
NOTESOnly carry out this conformity check after a full check with the diagnostic tool (fault
reading and configuration checks).
Test conditions: engine at idle speed,
AIR CONDITIONING OPERATING (air
conditioning compressor engaged).
NOTE: The interpretation of the statuses, parameters and controls listed in this check
is explained in the Technical Notes relating to the computer which generates the signal
(see the Introduction section).
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Climate controlET086:Heated rear
screen: manual
mode.ACTIVE: De-icing button at
the bottom of the control
panel pressed.
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET085:Heated rear
screen: auto
mode.ACTIVE: De-icing button at
the top of the control panel
pressed ("See clear"
function).
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
PR121:Blown air
temperature
setpoint.0 < X < 80 ˚C.If there is a fault, refer to the
fault finding procedure
for this parameter.
PR001:Interior
temperature.X = interior temperature
± 5 ˚C
(invalid value: 87.5 ˚C).If there is a fault, refer to the
fault finding procedure
for this parameter.
PR012:Mixing flap
position.0% = Max. cold position
(15 ˚C)
100% = Max. warm position
(27 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
ET141:Passenger
compartment
blower.RUNNING.
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for climate
control systems.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif
Page 36 of 60

62A - 36
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating (continued 1)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCHPR001:Battery voltage.12.5 < X < 14.4 volts.If there is a fault, refer to the
fault finding procedure
for this parameter. If the
fault is still present, carry
out fault finding on the
charge circuit.
PR002:Exterior
temperature.X = exterior temperature
± 5˚C
(invalid value: 215 ˚C).If there is a fault, refer to the
fault finding procedure
for this parameter.
ET025:Retractable roof.CLOSED or NOT CLOSED
ABSENT if the vehicle does
not have one.If there is a fault, refer to the
fault finding procedure
for this status.
ET091:Engine running:YES
NOTE: This status is
displayed by the UCH but it
is generated by the injection
computer.If there is a fault, refer to the
fault finding procedure
for this status.
(Injection Technical Note).
ET015:Passenger
compartment
blower.ACTIVE
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for manual air
conditioning(and heater
versions without air
conditioning).
ET026:Heated rear
screen switch.ACTIVE if the heated rear
screen is operating.
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET031:Fast idle request
for RCH.ACTIVE if the RCH are
operating.
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET017:Number RCH
required.0, 1, 2 or 3 for Mégane
saloons and sport hatches
(1000 watt RCH).
0, 1, 2, 3, 4 or 5 for Mégane
Scénics (1800 watt RCH).
(according to heat
requirement).If there is a fault, refer to the
fault finding procedure
for this status.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif
Page 37 of 60

62A - 37
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating (continued 2)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCH
(continued 1)ET018:Number RCH
authorised by
alternator.0, 1, 2 or 3 for Mégane
saloons and sport hatches
(1000 watt RCH).
0, 1, 2, 3, 4 or 5 for Mégane
Scénics (1800 watt RCH).
(depending on the electrical
availability).If there is a fault, refer to the
fault finding procedure
for this status.
ET019:Number RCH
authorised by
injection.0, 1, 2 or 3 for Mégane
saloons and sport hatches
(1000 watt RCH).
0, 1, 2, 3, 4 or 5 for Mégane
Scénics (1800 watt RCH).
(according to the injection's
requirements: power
requirement, torque
reduction, etc.).If there is a fault, refer to the
fault finding procedure
for this status.
ET020:Number RCH
actuated.0, 1, 2 or 3 for Mégane
saloons and sport hatches
(1000 watt RCH).
0, 1, 2, 3, 4 or 5 for Mégane
Scénics (1800 watt RCH).
(depending on statuses
"ET017, ET018 and
ET019").If there is a fault, refer to the
fault finding procedure
for this status.
ET021:RCH no. 1 control
relay.ACTIVE or INACTIVE
(depending on status
ET020).If there is a fault, refer to the
fault finding procedure
for this status.
ET022:RCH no. 2 control
relay.ACTIVE or INACTIVE
(depending on status
ET020).If there is a fault, refer to the
fault finding procedure
for this status.
ET023:RCH no. 3 control
relay (Mégane
Scénic and
Scénic 4x4 only).ACTIVE or INACTIVE
(depending on status
ET020).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is
inoperative for Mégane
saloons and Mégane sport
hatches.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif
Page 38 of 60

62A - 38
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating (continued 3)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCH
(continued 2)AC016:RCH no. 1 relay. Commands for testing the
operation of the RCH
(passenger compartment
air heating resistors). The
number of RCH stages
switched on depends on the
number of relays actuated.
NOTE: RCH no. 3 relay is
only fitted to Mégane
Scénics.If there is a fault, refer to the
fault finding procedure
for these controls.
NOTE: To find the relays
actuated/number of RCH
engaged correlation, refer
to the "general operation"
section of the UCH
Technical Note. AC017:RCH no. 2 relay.
AC018:RCH no. 3 relay.
(Mégane Scénics
only)
InjectionET024:Set number of
RCH.YES or NO
NOTE: According to the
injection's requirements:
power requirement, torque
reduction, etc., the injection
computer sets the number
of RCH stages switched on
(no more, no less).If there is a fault, refer to the
fault finding procedure
for this status.
PR064:Coolant
temperature.X = engine coolant
temperature.If there is a fault, refer to the
fault finding procedure
for this parameter.
Protection and
Switching UnitPR002:alternator charge
signal0 < X <100 %
–0 % = zero electrical
consumption.
–100 % = maximum
electrical consumption.If there is a fault, refer to the
fault finding procedure
for this parameter.
AC011:Heated rear
screen.Command for testing the
operation of the rear screen
heating.If there is a fault, consult the
fault finding procedure
for this command.
NOTE: The UPC cannot
test the heated rear screen
control circuit; this
command is the only way to
test its operation.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif
Page 43 of 60

62A-43
AIR CONDITIONING
Fault finding - Customer complaints62A
V4 MR-372-J84-62A000$070.mif
Manual air conditioning
and
Climate controlAIR CONDITIONING
Fault finding - Customer complaints
NOTESSpecial notes:
This section gives the complete list of possible customer complaints (the fault finding
charts are to be found in sections 62A, 62B and 62C: see below).
COMMUNICATION FAULT (only for regulated versions) Section 62B
NO DIALOGUE WITH THE COMPUTER ALP 1
AIR DISTRIBUTION PROBLEMSections 62B and 62C
AIR DISTRIBUTION PROBLEM ALP 2
AIR FLOW FAULT ALP 3
INEFFICIENT WINDSCREEN DEMISTING ALP 4
NO PASSENGER COMPARTMENT VENTILATION ALP 5
AIR CONDITIONING FAULTSection 62A
NO HEATING OR INADEQUATE HEATING ALP 6
EXCESSIVE HEATING ALP 7
NO COLD AIR ALP 8
TOO MUCH COLD AIR ALP 9
INEFFICIENT REAR SCREEN DE-ICING OR DEMISTING ALP 10
PASSENGER COMPARTMENT ODOURSSections 62B and 62C
UNPLEASANT ODOURS IN PASSENGER COMPARTMENT ALP 11
CLIM X84 1.1
Edition 2
Page 45 of 60

AIR CONDITIONING
Fault finding - Fault Finding Chart62A
62A-45V4 MR-372-J84-62A000$080.mif
Manual air conditioning
and
Climate controlAIR CONDITIONING
Fault finding - Fault Finding Chart
ALP 6 No heating or inadequate heating
NOTESOnly refer to this customer complaint after a full check with the diagnostic tool (fault
reading and configuration checks).
Is the air flow correct?
YES
Is the air distribution correct?
YES
With the engine warm, select the MAX heat position.
Is the blown air hot?
NO
Using the diagnostic tool statuses and parameters
screen (cold loop sub-function), check that the
temperature signals are correct (no sensor drift
resulting in incorrect measurement).
For manual air conditioning systems:
–External air temperature and engine coolant
temperature.
For climate control systems:
–External air temperature, engine coolant
temperature and internal air temperature.
Depending on the vehicle equipment, also check that
the internal air temperature sensor mini-turbine is
operating correctly (this can distort the measurement if
it is faulty).
Are the temperature signals consistent?
YES
NO
NO
YES
NOSee ALP 3, air flow fault.
See ALP 2, air distribution fault.
If necessary, explain how the
system works to the customer
again.
Carry out a conformity check on
the sensors (refer to the relevant
section).
Replace any faulty components.
AFTER REPAIRPerform a complete check using the diagnostic tool.
CLIM X84 1.1
Edition 2
Page 46 of 60

AIR CONDITIONING
Fault finding - Fault Finding Chart62A
62A-46V4 MR-372-J84-62A000$080.mif
Manual air conditioning
and
Climate control
ALP 6
CONTINUED
With the engine warm and
passenger compartment ventilation
operating, vary the position of the
mixing flap from the very cold
position to the very hot position and
check subjectively that there is a
difference in temperature.
Can you feel the difference in
temperature?
YES
NOFor climate control systems:
Carry out a conformity check on the mixing motor
(PR012 Mixing motor). If the conformity check does not
reveal any faults, look for a mechanical fault with the
mixing flap (condition of the motor's toothed sector, flap
jammed inside the unit, etc.).
For manual air conditioning and heater versions:
Check the condition and routing of the mixing flap
control cable. Eliminate any constraints on it: kinks,
cable restricted by plastic clips, etc. Replace it if
necessary. Unclip the cable from the side of the unit and
check the stiffness of movement of each component:
control button and flap control on the air distribution unit.
Check that there is no mechanical fault with the mixing
flap (flap jammed inside the unit, etc.).
Carry out any necessary repairs.
Is the fault still present?
YES
Is the lower heater matrix pipe
(coolant inlet) hot?
NOTE: Pipe located on the left-hand
side of the heater-air conditioning
unit, near the engine bulkhead.
YES
Check that the heater matrix is not blocked: The top heater matrix pipe should be hot.
NOTE: Pipe located on the left-hand side of the heater-air conditioning unit, near the engine
bulkhead. Clean the heater matrix or replace it if necessary.
Is the fault still present?
YES NO
If the vehicle is fitted with passenger compartment heating
resistors (RCH), check that these are operating correctly by
referring to the fault finding procedure in the UCH Technical Note.
NOCarry out a check on the coolant circuit and
ensure that the thermostatic valve opens at the
correct temperature.
Replace the valve if necessary.
NO
End of fault finding procedure.
AFTER REPAIRPerform a complete check using the diagnostic tool.
CLIM X84 1.1
Edition 2
Page 48 of 60

62A-48
AIR CONDITIONING
Fault finding - Fault Finding Chart62A
V4 MR-372-J84-62A000$080.mif
Manual air conditioning
and
Climate control
ALP 7
CONTINUED
For climate control systems:
Using the diagnostic tool statuses and parameters screen (passenger compartment ventilation sub-function),
check that the recirculation flap is in the external air position: status ET062 Recirculation flap position should
display OPEN. If it is closed when the user does not want recirculation, use the fault finding procedure for fault:
DF021 Recirculation motor circuit.
For manual air conditioning systems:
check that the recirculation flap is in the external air position. If this is not operating correctly (impossible to change
the flap to the exterior air position), check the condition and routing of the recirculation flap control cable. Eliminate
any constraints on it: kinks, cable restricted by plastic clips, etc.
Replace it if necessary.
Check that there is no mechanical fault with the recirculation flap (flap jammed).
Carry out any necessary repairs.
Is the fault still present?
YES NO
Is the lower heater matrix pipe (coolant
inlet) hot?
NOTE: Pipe located on the left-hand
side of the heater-air conditioning unit,
near the engine bulkhead.NOCarry out a check on the
coolant circuit and ensure
that thermostatic valve
opens at the correct
temperature.
Replace the valve if
necessary.
YES
If the vehicle is fitted with passenger compartment heating resistors,
check that these are operating correctly (not switching on
unnecessarily) by referring to the fault finding procedure contained in
the UCH technical note.
End of fault finding procedure.
AFTER REPAIRPerform a complete check using the diagnostic tool.
CLIM X84 1.1
Edition 2
Page 50 of 60

AIR CONDITIONING
Fault finding - Fault Finding Chart62A
62A-50V4 MR-372-J84-62A000$080.mif
Manual air conditioning
and
Climate control
ALP 8
CONTINUED 1
With the engine running at idle speed, use the
diagnostic tool to check that the UCH does in fact
send the start air conditioning request to the
injection computer. Status ET030 AIR
CONDITIONING REQUEST 2 should display
ACTIVE.
Is the correct status displayed? NO
YES YES
View the following states on the diagnostic tool
(cold loop subsystem screen):
–ET004 AIR CONDITIONING
AUTHORISATION: this status should be
displayed as YES,
–ET088 COMPRESSOR ENGAGEMENT
REQUEST: this status should be displayed as
ACTIVE.
Are the correct statuses displayed? YES
NO
Check that the injection computer is correctly configured. Status ET079 AIR CONDITIONING PRESENT should
display YES (cold loop sub-function screen).
NOTE: Status ET079 is present in all injection systems.
S3000 injection (K4J, K4M, F4R and F4RT engines) has 2 additional configuration readings:
–LC009 "AIR CONDITIONING" should display "CONNECTED",
–LC016 "AIR CONDITIONING PRESSURE SIGNAL MANAGEMENT" should display "WITH".
Is the injection computer correctly configured?
YES NO
Reconfigure the injection computer (automatic
configuration: see the "Introduction" section in the
Injection note).
Check that the UCH is correctly configured
by viewing the configuration reading
LC013 TYPE OF AIR CONDITIONING.
Reconfigure the UCH if necessary.
Check that the UCH is receiving the engine
operating status and passenger
compartment fan signals correctly (for
manual air conditioning).
On the heating sub-function screen, status
ET091 ENGINE RUNNING should display
YES and status ET015 PASSENGER
COMPARTMENT FAN should display
ACTIVE.
Are the correct statuses displayed?
NO
Carry out a fault finding procedure on the
multiplex network, the injection
(interpretation of status ET091), and the
UCH (interpretation of status ET015).
AFTER REPAIRPerform a complete check using the diagnostic tool.
CLIM X84 1.1
Edition 2