engine coolant RENAULT SCENIC 2010 J95 / 3.G Petrol Injection S3000 Injection User Guide
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2010, Model line: SCENIC, Model: RENAULT SCENIC 2010 J95 / 3.GPages: 230, PDF Size: 0.92 MB
Page 55 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-55
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-55V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF061
PRESENT
OR
STOREDCOMBUSTION MISFIRING ON CYLINDER 3
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– ignition: DF361 Ignition coil circuit cylinders 1-4
DF362 Ignition coil circuit cylinders 2-3
– fuel supply circuit:
DF026 Injector control circuit cylinder 1,
DF027 Injector control circuit cylinder 2,
DF028 Injector control circuit cylinder 3,
DF029 Injector control circuit cylinder 4,
DF085 Fuel pump relay control circuit.
– engine flywheel signal: DF154 Flywheel signal sensor circuit
DF457 Flywheel target
Check whether there are other cylinders with a combustion misfire fault detected by the
tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (coolant temperature 75°C minimum),
– engine running at idling speed with all electrical consumers on for approximately
15 minutes.
Special note:
–OBD warning light illuminated.
1.DEF
NOTESSpecial note:
– As soon as the fault is detected, the injection is cut off on
the faulty cylinder(s) to limit the temperature increase in
the catalytic converter,
– if a fault is present, the OBD warning light flashes.
2.DEFSpecial note:
–the OBD warning light remains continuously lit.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF061/S3000_V54_DF061
Page 57 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-57
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-57V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF062
PRESENT
OR
STOREDCOMBUSTION MISFIRING ON CYLINDER 4
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– ignition: DF361 Ignition coil circuit cylinders 1-4
DF362 Ignition coil circuit cylinders 2-3
– fuel supply circuit:
DF026 Injector control circuit cylinder 1,
DF027 Injector control circuit cylinder 2,
DF028 Injector control circuit cylinder 3,
DF029 Injector control circuit cylinder 4,
DF085 Fuel pump relay control circuit.
– engine flywheel signal: DF154 Flywheel signal sensor circuit
DF457 Flywheel target
Check whether there are other cylinders with a combustion misfire fault detected by the
tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (coolant temperature 75°C minimum),
– engine running at idling speed with all electrical consumers on for approximately
15 minutes.
Special note:
–OBD warning light illuminated.
1.DEF
NOTESSpecial note:
– As soon as the fault is detected, the injection is cut off on
the faulty cylinder(s) to limit the temperature increase in
the catalytic converter,
– if a fault is present, the OBD warning light flashes.
2.DEFSpecial note:
–the OBD warning light remains continuously lit.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF062/S3000_V54_DF062
Page 82 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-82
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-82V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF109
PRESENT
OR
STOREDLOW FUEL LEVEL MISFIRING
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– fuel supply circuit:
DF085 Fuel pump relay control circuit,
DF026 Injector control circuit cylinder 1,
DF027 Injector control circuit cylinder 2,
DF028 Injector control circuit cylinder 3,
DF029 Injector control circuit cylinder 4
– combustion misfiring:
DF059 Combustion misfire in cylinder 1,
DF060 Combustion misfire in cylinder 2,
DF061 Combustion misfire in cylinder 3,
DF062 Combustion misfire in cylinder 4.
Conditions for applying the fault finding procedure to stored faults:
The fault is present after starting the engine and under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (coolant temperature 75°C minimum),
– engine running with electrical consumers on for 15 minutes.
Special note:
–OBD warning light illuminated.
Check the presence and conformity of the fuel in the tank.
If there is no present or stored combustion misfire fault, the misfire was caused by the low fuel level.
Clear fault DF109.
AFTER REPAIREnsure that all the faults have been dealt with.
Do not clear the programming.
To check that the system has been repaired correctly:
– there must be no further electrical faults,
– programming has been carried out,
– warm engine (minimum 75°C).
– running at idle speed with all electrical consumers drawing power for 15 minutes.
If the fault reappears, continue the fault finding procedure.
S3000_V4C_DF109/S3000_V54_DF109
Page 99 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-99
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-99V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF394
PRESENT
OR
STOREDCATALYTIC CONVERTER OPERATING FAULT
1.DEF: Component in bad condition
2.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Deal with the other faults first.
There must be no other injection system faults, either present or stored.
– combustion misfiring:
DF059 Combustion misfire in cylinder 1,
DF060 Combustion misfire in cylinder 2,
DF061 Combustion misfire in cylinder 3,
DF062 Combustion misfire in cylinder 4, in 1.DEF or 2.DEF.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming done,
– warm engine (coolant temperature 75°C minimum),
– engine running at idling speed with all electrical consumers on for approximately
15 minutes.
Special note:
–OBD warning light illuminated.
Check the appearance and condition of the catalytic converter.
Check that there is no air leaking in, heat shock, misfires, consumption of coolant or oil.
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF394/S3000_V54_DF394
Page 107 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-107
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-107V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF570
PRESENT
OR
STOREDCOOLANT PUMP RELAY
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the engine is running or on command AC195
Electric coolant pump.
Check the cleanliness, condition and fitting of the coolant pump.
Top up the coolant if necessary.
If the fault is still present, manipulate the harness to see if the status changes.
Look for any harness damage, and check the condition and connection points of the injection computer and the
coolant pump connectors.
Repair if necessary.
If the fault is still present, check for +12V on track 2 of the coolant pump.
If +12V is not present on track 2 of the coolant pump, check the following connection for insulation, continuity
and the absence of interference resistance:
Coolant pump track 2 track 6, connector CN, of the Protection and
Switching Unit
Repair if necessary.
If the fault is still present, check the insulation, continuity and the absence of interference resistance on the
following connection:
Computer, connectorB, track L4 track 1 of the coolant pump
Repair if necessary.
If the fault is still present, check that the resistance between tracks 1 and 2 of the coolant pump is neither zero
nor infinite.
Replace the coolant pump if necessary.
If the fault is still present, deal with the other faults then proceed to the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF570/S3000_V54_DF570
Page 121 of 230

PETROL INJECTION
Fault finding - Conformity check
17B
17B-121
PETROL INJECTION
Fault finding - Conformity check
17B
17B-121V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
SUB FUNCTION: SUB-FUNCTION (TURBOCHARGING/INLET):
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
1
Air circuit
pressurePR035:Atmospheric
pressurePR035 = 1000 mb
± 100 mbIf not consistent, check
PR035 = PR312 = local
atmospheric pressure,
with the engine stopped
and ignition on.
2 PR312:Inlet manifold
vacuumPR312 = 1000 mb
± 100 mbIn the event of a fault
apply the interpretation for
PR312 Inlet manifold
vacuum.
3 Engine speed PR055:Engine speedIndicates the engine's
speed of rotation in
rpm.
PR055 = 0 rpmIn the event of a fault,
apply the interpretation for
DF154 Flywheel signal
sensor circuit.
4
Idle speedET054:Idle speed
regulationINACTIVE None
5 PR010:Idle speed
regulation
setting700 < X < 750 rpm
Indicates the speed of
rotation setpoint before
last engine stop in rpm.None
6Air
temperaturePR058:Air
temperature- 40°C < PR058 < 120°C
Default value: 120°CIn the event of a fault,
apply the interpretation of
DF002 Air temperature
sensor circuit.
7 Coolant
temperaturePR064:Coolant
temperature- 40°C < PR064 < 120°C
Default value: - 39°CIn the event of a fault,
apply the interpretation of
DF001 Coolant
temperature sensor
circuit.
Page 122 of 230

PETROL INJECTION
Fault finding - Conformity check
17B
17B-122
PETROL INJECTION
Fault finding - Conformity check
17B
17B-122V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
SUB FUNCTION: (TURBO/INLET) (continued):
OCR: Opening Cycle Ratio
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
8 Air flow PR018:Estimated air
flowIndicates the air flow
value estimated by the
motorised throttle
valve.
PR018= 0kg/hIf there is a fault, apply the
interpretation of faults
DF095 Throttle
potentiometer circuit
gang 1 and DF096
Throttle potentiometer
circuit gang 2.
9
Camshaft
dephaser (Only
on K4M
engines)ET083:Camshaft
dephaser in
defect modeSTATUS 1: This defect
mode covers all faults
that affect the dephaser
position measurement.
The dephaser is set to the
lower stop and the
camshaft angle
measurement is forced
to 0. Tooth signal fault.
STATUS 2: This defect
mode covers all faults
that affect the dephaser
(pulley and solenoid
valve). The dephaser is
set to the low stop.
NOFor STATUS 1, carry out
a camshaft signal/tooth
consistency diagnostic.
For STATUS 2, carry out
fault finding on the
camshaft dephaser
position.
10 PR094:Camshaft
dephaser OCR
setpointShows required camshaft
offset value (in %).
PR094 = 0%
WITHOUT
11 ET086:Camshaft
dephaser
controlACTIVE
INACTIVE
12electric coolant
pumpAC195:Electric coolant
pumpThe pump should be
heard operatingIn the event of a fault,
apply interpretation of
DF570 Coolant pump
relay.
Page 134 of 230

PETROL INJECTION
Fault finding - Conformity check
17B
17B-134
PETROL INJECTION
Fault finding - Conformity check
17B
17B-134V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
SUB-FUNCTION: IGNITION/PREHEATING (continued 1):
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status Checked
or ActionDisplay and notes Fault finding
9ET581:Petrol combustion
misfire fault findingINACTIVEIn the event of a fault,
apply interpretation of
faults DF059
Combustion misfire
in cylinder 1, DF060
Combustion misfire
in cylinder 2, DF061
Combustion misfire
in cylinder 3, DF062
Combustion misfire
in cylinder 4. 10
Combustion
misfireET057:Misfiring on cylinder 1NO
11 ET058:Misfiring on cylinder 2NO
12 ET059:Misfiring on cylinder 3NO
13 ET060:Misfiring on cylinder 4NO
14 ActuatorsAC079
:Actuator static testAll the actuators must
be operated (fuel
pump relay, electric
coolant pump on
F4RT, downstream
and upstream sensor
heating, motorised
throttle)In the event of a fault,
apply interpretation of
fault associated with
the actuators
concerned.
Page 135 of 230

PETROL INJECTION
Fault finding - Conformity check
17B
17B-135
PETROL INJECTION
Fault finding - Conformity check
17B
17B-135V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
IGNITION/PREHEATING SUB-FUNCTION (continued 2):
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status Checked
or ActionDisplay and notes Fault finding
15
Combustion
misfire
GasET582:LPG combustion
misfire fault findingINACTIVEIn the event of a fault,
apply interpretation of
faults DF635
Combustion misfire
in LPG cylinder 1,
DF636 Combustion
misfire in LPG
cylinder 2, DF637
Combustion misfire
in LPG cylinder 3,
DF638 Combustion
misfire in LPG
cylinder 4. 16 ET583:LPG cylinder 1
combustion misfireNO
17 ET584:LPG cylinder 2
combustion misfireNO
18 ET585:LPG cylinder 3
combustion misfireNO
19 ET586:LPG cylinder 4
combustion misfireNO
20 Actuators AC079:Actuator static testAll the actuators
must be operated
(fuel pump relay,
electric coolant
pump on F4RT,
downstream and
upstream sensor
heating, motorised
throttle)In the event of a fault,
apply interpretation of
fault associated with
the actuators
concerned.
Page 136 of 230

PETROL INJECTION
Fault finding - Conformity check
17B
17B-136
PETROL INJECTION
Fault finding - Conformity check
17B
17B-136V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
COLD LOOP SUB-FUNCTION:
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
1
Air conditioningET079:Air conditioning
presentShows whether or not
the vehicle is equipped
with air conditioning.
YES: Air conditioning is
detected by the injection
computer.
NO: Air conditioning is not
detected by the injection
computer.If inconsistent with
the vehicle
equipment, carry out
a multiplex network
test and apply the
relevant procedure.
2 ET088:Compressor
actuation
requestThe injection requests
the UCH (via the
multiplex network) to
start the compressor.
ACTIVE: The multiplex
network must not be faulty
on the automatic gearbox
or UCH systems. The
UCH must send a
compressor starting
request to the injection.
The coolant pressure
sensor must not be
defective. Satisfactory
engine operating
conditions (coolant
temperature, engine load,
etc.).
INACTIVE: One of the
above conditions has not
been met.WITHOUT
3 ET004:Air conditioning
authorisationYES
NO