37B-27
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults37B
DF025
PRESENT
OR
STOREDVEHICLE MOVEMENT WITH MAXIMUM APPLICATION
1. DEF: The computer has detected vehicle movement when parked (parking brake
applied)
NOTESPriorities when dealing with a number of faults:
First deal with faults DF046 Brake motor/cables connection, DF042 Force sensor,
DF035 Undervoltage, DF041 Slope sensor, DF049 Brake application, DF054
Battery voltage too high and DF055 Battery undervoltage, if they are present or
stored.
If none of these faults is present or stored, the parking brake computer is not normally
the cause.
Conditions for applying the fault finding procedure to a stored fault:
Apply the fault finding procedure even if the fault is stored.
Note:
The fault does not remain present after it has been detected.
Special notes:
– this fault indicates that the electronic parking brake computer detected movement
of the vehicle although the parking brake was applied.
– if this fault is present, with the ignition on, the buzzer on the instrument panel is
activated (when the vehicle is moving with the parking brake applied).
This fault is an operational warning. Check the context in which it appears.
It may appear during:
– an application request, whilst the vehicle is still being driven,
– forced assisted release when starting, when the starting conditions have not
been met,
– parked on a steep slope with slippery surface,
– incorrect use of a roller test bench (MOT test).
Only for Vdiag 08 and 0C:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction section.
If the fault is stored and PR018 = 0 and PR022 > 25, clear the fault: do not take this
fault into account.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF025/FPA_V04_DF025/FPA_V08_DF025
FPA
Vdiag No.: 0C, 04, 08
Page 31 of 115
37B-31
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF035
PRESENT
OR
STOREDUNDERVOLTAGE
1. DEF: Insufficient feed voltage during the command
NOTESPriority in the event of a number of faults:
Deal with fault DF055 Battery undervoltage first if it is present or stored.
Conditions for applying the fault finding procedure to a stored fault:
Apply this fault finding procedure if the fault reappears after the ignition has been
switched off and on again (+ forced after ignition feed: see Introduction) and an
application or release request using the control lever.
Special notes:
This fault is a power supply fault and does not usually stem from the electronic
parking brake computer.
This fault does not indicate computer feed undervoltage but a significant drop in
voltage to the parking brake motor while the command is being issued.
Only for Vdiag 08, 0C and 0D:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction.
If the fault is stored and PR018 = 0 and PR022 > 25, clear the fault:
do not take this fault into account.
Disconnect the electronic parking brake computer connector to check the conformity of the supplies and to
check the insulation, continuity and the absence of interference resistance on the following connections:
Electronic parking brake computer connector
track H4
(except Laguna II, Vel Satis and Espace IV)
track G4+12V
track H2
(except Laguna II, Vel Satis and Espace IV)
track G2earth
Repair if necessary (see the vehicle wiring diagram).
Apply the brake and then release it (engine running) to check that during the command the voltage measured at
the fuse does not drop below 10.5 V.
Make the repairs necessary for the parking brake computer electrical supply to be correct (equal to the battery
voltage).
If the fault persists, contact the Techline.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF035/FPA_V04_DF035/FPA_V08_DF035/FPA_V0D_DF035/FPA_V11_DF035
Page 32 of 115
37B-32
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF036
PRESENT
OR
STOREDINJECTION MULTIPLEX SIGNAL ABSENT
1. DEF: Multiplex signals absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESPriority in the event of a number of faults:
Deal with faults DF055 Battery undervoltage and DF052 Multiplex network first if
they are present or stored.
Deal with any injection computer faults first.
The fault does not usually come from the electronic parking brake computer.
Note:
If there is a multiplex line fault like this one, the parking brake loses its assisted
application and release functions.
Conditions for applying the fault finding procedure to a stored fault:
Apply this fault finding procedure if the fault reappears as present or stored after a
fault has been cleared, and the ignition has been switched off and on again (forced
+ after ignition feed: see Introduction).
Special notes:
This fault only relates to multiplex signals received from the injection computer.
This fault indicates either that there is no transmission, or that the signals received by
the parking brake are inconsistent.
Only for Vdiag 08, 0C and 0D:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction section.
If the fault is stored and PR018 = 0 and PR022 > 25, clear the fault:
do not take this fault into account.
If the fault is stored and PR019 < 10, clear the fault:
do not take this fault into account.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF036/FPA_V04_DF036/FPA_V08_DF036/FPA_V0D_DF036/FPA_V11_DF036
Page 34 of 115
37B-34
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF037
PRESENT
OR
STOREDNO ABS MULTIPLEX SIGNAL
1. DEF: Multiplex signals absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESPriority in the event of a number of faults:
Deal with faults DF055 Battery undervoltage and DF052 Multiplex network first if
they are present or stored.
Deal with any ABS computer faults first.
The fault does not usually come from the electronic parking brake computer.
Note:
If this fault is present, the parking brake loses its assisted application and release
functions.
Conditions for applying the fault finding procedure to a stored fault:
Apply this fault finding procedure if the fault reappears as present or stored after a
fault has been cleared and the ignition has been switched off and on again
(forced + after ignition feed: see Introduction).
Special notes:
This fault only relates to multiplex signals received from the ABS computer.
This fault indicates either that there is no transmission, or that the signals received by
the electronic parking brake computer are inconsistent.
Only for Vdiag 08, 0C and 0D:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction.
If the fault is stored and PR018 = 0 and PR022 > 25, clear the fault:
do not take this fault into account.
If the fault is stored and PR019 < 10, clear the fault:
do not take this fault into account.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF037/FPA_V04_DF037/FPA_V08_DF037/FPA_V0D_DF037/FPA_V11_DF037
Page 36 of 115
37B-36
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF038
PRESENT
OR
STOREDNO AUTOMATIC TRANSMISSION MULTIPLEX SIGNAL
1. DEF: Multiplex signals absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESPriority in the event of a number of faults:
Deal with faults DF055 Battery undervoltage and DF052 Multiplex network first if
they are present or stored.
Deal with any automatic transmission computer faults first.
The fault does not usually come from the electronic parking brake computer.
Note:
If this fault is present, the parking brake loses its assisted application and release
functions.
Conditions for applying the fault finding procedure to a stored fault:
Apply this fault finding procedure if the fault reappears as present or stored after a
fault has been cleared, and the ignition has been switched off and on again (forced
+ after ignition feed: see Introduction).
Special notes:
This fault only relates to multiplex signals received from the automatic transmission
computer.
This fault indicates either that there is no signal or that the signals transmitted are
inconsistent.
Only for Vdiag 08, 0C and 0D:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction.
If the fault is stored and PR018 = 0 and PR022 > 25, clear the fault:
do not take this fault into account.
If the fault is stored and PR019 < 15 clear the fault:
do not take this fault into account.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF038/FPA_V04_DF038/FPA_V08_DF038/FPA_V0D_DF038/FPA_V11_DF038
Page 38 of 115
37B-38
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF039
PRESENT
OR
STOREDNO UCH MULTIPLEX SIGNAL
1. DEF: Multiplex signals absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESPriority in the event of a number of faults:
Deal with faults DF055 Battery undervoltage and DF052 Multiplex network first if
they are present or stored.
Deal with any UCH computer faults first.
The fault does not usually come from the electronic parking brake computer.
Note:
If this fault is present, the parking brake loses its assisted application and release
functions.
Conditions for applying the fault finding procedure to a stored fault:
Apply this fault finding procedure if the fault reappears as present or stored after a
fault has been cleared and the ignition has been switched off and on again
(forced + after ignition feed: see Introduction).
Special notes:
This fault only relates to multiplex signals received from the UCH computer.
This fault indicates either that there is no signal or that the signals transmitted are
inconsistent.
Only for Vdiag 08, 0C and 0D:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction.
If the fault is stored and PR018 = 0 and PR022 > 25, clear the fault:
do not take this fault into account.
If the fault is stored and PR019 < 15 clear the fault:
do not take this fault into account.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF039/FPA_V04_DF039/FPA_V08_DF039/FPA_V0D_DF039/FPA_V11_DF039
Page 41 of 115
37B-41
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF042
PRESENT
OR
STOREDFORCE SENSOR
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1. DEF: Sensor supply fault
2 CO.0: Open circuit or short circuit to earth
CC.1
1. DEF
NOTESPriorities when dealing with a number of faults:
This fault must be dealt with first.
Special notes:
The force sensor is internal to the electronic parking brake
computer; it cannot be separated.
Before replacing an electronic parking brake computer,
save the data from the old computer (for vehicles fitted
with a manual gearbox).
For this operation, (see Replacement of components).
Contact the Techline without clearing the faults.
CC.0
NOTESPriority when dealing with a number of faults:
Deal with faults DF055 Battery undervoltage and DF052
Multiplex network first if they are present or stored.
Special notes:
The force sensor is internal to the electronic parking brake
computer; it cannot be separated.
Before replacing a parking brake control unit, save the data
from the old computer (for vehicles fitted with a manual
gearbox).
For this operation, (see Replacement of components).
Contact the Techline without clearing the faults.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF042/FPA_V04_DF042/FPA_V08_DF042/FPA_V0D_DF042/FPA_V11_DF042
Page 44 of 115
37B-44
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF044
PRESENT
OR
STOREDBRAKING SWITCH
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
NOTESPriority when dealing with a number of faults:
Deal first with faults DF047 Manual control, DF035 Undervoltage, DF055 Battery
undervoltage and DF054 Battery voltage too high, if they are present or stored.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the ignition is switched on (forced + after ignition
feed, see Introduction) and an application request using the control lever.
The fault does not usually come from the electronic parking brake computer.
Special notes:
The braking switch is in fact the first contact of the lever (the lever travels about
3mm).
This fault appears naturally when the lever is disconnected.
Note:
The fault warning light comes on 10 seconds after the fault appears.
Only for Vdiag 08, 0C and 0D:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction.
If the fault is stored and PR018 = 0 and PR022 > 25, clear the fault:
do not take this fault into account.
If the fault is stored and PR019 < 3, clear the fault:
do not take this fault into account.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF044/FPA_V04_DF044/FPA_V08_DF044/FPA_V0D_DF044/FPA_V11_DF044
Page 47 of 115
37B-47
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF045
PRESENT
OR
STOREDREDUNDANT BRAKE SWITCH
1. DEF: Signal inconsistency
NOTESPriority when dealing with a number of faults:
Deal first with faults DF047 Manual control, DF035 Undervoltage and DF055
Battery voltage too low, if they are present or stored.
Conditions for applying the fault finding procedure to a stored fault:
This fault must be dealt with first.
Special notes:
The fault does not usually come from the electronic parking brake computer.
The redundant brake switch is the second contact of the lever (maximum lever travel).
Only for Vdiag 08, 0C and 0D:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction.
If the fault is stored and PR018 = 0 and PR022 > 25 clear the fault: do not take this
fault into account.
If the fault is stored and PR019 < 3, clear the fault: do not take this fault into account.
Using the diagnostic tool (PARKING sub-function), check the operation of the parking brake control lever. With
the ignition switched on, statuses ET008, ET009 and ET010 should operate as follows:
ET008 "Engagement
switch position"ET009 "Redundant
braking switch position"ET010 "Release switch
position"
Lever at rest INACTIVE INACTIVE RELEASED
Lever pulled slightly
(3 mm travel)ACTIVE INACTIVE RELEASED
Lever pulled to end of
travelACTIVE ACTIVE RELEASED
Lever pulled and release
switch pressedACTIVE ACTIVE PRESSED
If the statuses do not operate as explained above, check the connection and condition of the parking brake
control lever connector.
Repair if necessary.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF045/FPA_V04_DF045/FPA_V08_DF045/FPA_V0D_DF045/FPA_V11_DF045
Page 50 of 115
37B-50
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF047
PRESENT
OR
STOREDMANUAL CONTROL
1. DEF: No signal
2. DEF: Signal inconsistency
3. DEF: Short circuit
4. DEF: Lever fault
NOTESPriorities when dealing with a number of faults:
Deal with faults: DF035 Undervoltage, DF055 Battery undervoltage and DF054
Battery voltage too high first, if they are present or stored.
Note:
The fault does not usually come from the electronic parking brake computer.
The fault is only stored after the brakes have been applied 3 times with the control
level.
Conditions for applying the fault finding procedure to a stored fault:
Deal with the fault as if it were present.
Only for Vdiag 08, 0C and 0D:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction.
If the fault is stored and PR018 = 0 and PR022 > 25 clear the fault: do not take this
fault into account.
If the fault is stored and PR019 < 3, clear the fault: do not take this fault into account.
Using the diagnostic tool (PARKING sub-function), check the operation of the parking brake control lever. With the
ignition switched on, statuses ET008, ET009 and ET010 should operate as follows:
ET008 "Engagement
switch position"ET009 "Redundant
braking switch position"ET010 "Release switch
position"
Lever at rest INACTIVE INACTIVE RELEASED
Lever pulled slightly
(3 mm travel)ACTIVE INACTIVE RELEASED
Lever pulled to end of
travelACTIVE ACTIVE RELEASED
Lever pulled and release
switch pressedACTIVE ACTIVE PRESSED
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF047/FPA_V04_DF047/FPA_V08_DF047/FPA_V0D_DF047/FPA_V11_DF047