ad blue RENAULT SCENIC 2013 J95 / 3.G Electronic Parking Brake Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2013, Model line: SCENIC, Model: RENAULT SCENIC 2013 J95 / 3.GPages: 115, PDF Size: 0.64 MB
Page 71 of 115
37B-71
MR-372-J84-37B000$576.mif
V11
37B
ELECTRONIC PARKING BRAKE
Fault finding – Conformity check
MAIN SCREEN
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, make sure that
the multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes:
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay
and notesFault finding
1Parking brake
operation statusET024:System operationCUSTOMER MODEIf the status displays FACTORY
MODE, the computer is not
operational.
To enter CUSTOMER MODE,
initialise the computer again, by
running command VP011
Computer calibration and
initialisation (see
Replacement of components).
2Computer
electrical supplyET001:+ After ignition
feedIgnition off: ABSENT
Ignition on: PRESENTIn the event of a fault on this
status, refer to the interpretation
of status ET001: + after
ignition supply.
PR001:Battery voltage9.6V
insulation, continuity and the
absence of interference
resistance on the computer
supplies and earths (see wiring
diagram). If the fault is still
present, carry out fault finding
on the charging circuit (see
Technical Note 6014A,
Checking the charging
circuit).
FPA_V0C_CCONF / FPA_V04_CCONF / FPA_V08_CCONF / FPA_V0D_CCONF / FPA_V11_CCONF
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
MR-372-J84-37B000$576.mif
Page 72 of 115
37B-72
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
MAIN SCREEN (CONTINUED 1)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, make sure that
the multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay and
notesFault finding
3Electronic
parking brakePR005: Force setting In rest position:
X = 0 N
When applying the brake
on a level surface:
400 < X < 550 N
When fully applied (lever
fully pulled for 2 seconds)
on a level surface:
1100 < X < 1150 N
Note: depressing the
brake pedal once when
the parking brake is
applied changes the
measured force value
(change in the tension of
the brake cables) and the
parking brake may be
over-applied.
Interpretation of these
parameters is only valid
without any pressure on
the brake pedal.The difference between the
reference and measured
values must not be more than
-50 N or + 100 N. If the
measured value does not
reach or exceeds the reference
value (mechanical or electrical
fault with the control), the
electronic parking brake
computer will detect a fault
(DF025 Vehicle movement
with maximum application,
DF049 Brake application or
DF050 Mechanical jamming).
If one of these three faults is
displayed by the diagnostic
tool, use the relevant
interpretation. PR004:Measured force
value
Page 73 of 115
37B-73
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
MAIN SCREEN (CONTINUED 2)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, make sure that
the multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay and
NotesFault finding
Electronic
parking brake
(continued)ET011:Parking brakeNo movement of the
lever:
INACTIVE
When released:
Released (while
releasing, then
INACTIVE).
When applying the brake:
STATUS 1 Static
braking
During emergency
braking:
STATUS 2 Dynamic
braking (over 6 mph
(10 km/h)).
When the system is
faulty:
DEFECTIVEIf the status does not operate
as specified, refer to the
interpretation of fault DF043
Parking brake motor.
Page 74 of 115
37B-74
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
SUB FUNCTION: PARKING
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, make sure that
the multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
1Computer
electrical supplyET001:+ After ignition
feedIgnition off: ABSENT
Ignition on:
PRESENTIn the event of a fault on this
status, refer to the interpretation of
status ET001: + after ignition
supply.
PR001:Battery voltage9V
continuity and the absence of
interference resistance on the
computer supplies and earths
(see wiring diagram). If the fault is
still present, carry out fault
finding on the charging circuit
(see Technical Note 6014A,
Checking the charging circuit).
ET009:Redundant
braking switch
positionLever released:
INACTIVE
Lever pulled to the
second contact (end of
travel):
ACTIVEIf the status does not operate as
specified, use the interpretation
of status ET009 Redundant
braking switch position.
ET010:Release switch
positionLever in rest position
RELEASED
Lever fully pulled and
releasing switch
pressed: PRESSEDIf the status does not operate as
specified, apply the
interpretation of status ET010
Releasing switch position.
Page 75 of 115
37B-75
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
SUB-FUNCTION: PARKING (CONTINUED 1)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, make sure that
the multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
2Parking brake
control leverET008:Braking switch
positionLever released:
INACTIVE
Lever pulled to the first
contact (approximately
3mm
travel):
ACTIVEIf the status does not operate as
specified, apply the
interpretation of status ET008
Brake application switch
position.
ET009:Redundant
braking switch
positionLever released:
INACTIVE
Lever pulled to the
second contact (end of
travel):
ACTIVEIf the status does not operate as
specified, use the
interpretation of status ET009
Redundant braking switch
position.
ET010:Release switch
positionLever in rest position
RELEASED
Lever fully applied and
release switch pressed:
PRESSEDIf the status does not operate as
specified, apply the
interpretation of status ET010
Releasing switch position.
Page 76 of 115
37B-76
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
SUB-FUNCTION: PARKING (CONTINUED 2)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, make sure that
the multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay
and notesFault finding
3Parking brake
assistPR005:Force setting In rest position:
X = 0 N
When applying the brake
on a level surface:
400 < X < 550 N
When fully applied (lever
fully pulled for 2 seconds)
on a level surface:
1100 < X < 1150 N
Note: depressing the
brake pedal once when
the parking brake is
applied changes the
measured force value
(change in the tension of
the brake cables) and the
parking brake may be
over-applied.
Interpretation of these
parameters is only
valid without any
pressure on the brake
pedal.The difference between the
reference and measured
values must not be more than
-50 N or + 100 N.
If the measured value does not
reach or exceeds the reference
value (mechanical or electrical
fault with the control), the
electronic parking brake
computer will detect a fault
(DF025 Vehicle movement
with maximum application,
DF049 Brake application or
DF050 Mechanical jamming).
If one of these three faults is
displayed by the diagnostic
tool, use the relevant
interpretation. PR004:Measured force
value
Page 77 of 115
37B-77
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
SUB-FUNCTION: PARKING (CONTINUED 3)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, make sure that
the multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
checked
or ActionDisplay and
NotesFault finding
ET011:Parking brakeNo movement of the lever:
INACTIVE
When released: Released
(while releasing, then
INACTIVE). When
applying the brake:
STATUS 1 Static braking
During emergency
braking:
STATUS 2 Dynamic
braking (over 6 mph
(10 km/h)). When the
system is faulty:
DEFECTIVEIf the status does not operate as
specified, refer to the
interpretation of fault DF043
Parking brake motor.
4BrakingAC002: BrakingACTIVE or INACTIVE
5ReleaseAC003: ReleaseACTIVE or INACTIVE
Page 78 of 115
37B-78
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
SUB-FUNCTION: AUTOMATIC APPLICATION
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, check that the
multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
1Assisted
braking
configurationET022:Automatic
braking
configurationWITH or WITHOUTDepending on the customer's
request, the electronic parking
brake computer may be
configured WITH or WITHOUT
assisted braking when the
engine stops. Refer to the
interpretation of status ET022
Automatic braking
configuration.
2Computer
electrical supplyET001:+ After ignition
feedIgnition off: ABSENT
Ignition on: PRESENTIn the event of a fault on this
status, refer to the interpretation
of status ET001: + after ignition
feed.
3EnginePR015:Engine speed0rpmIn the event of a fault with this
parameter and these statuses,
make sure that the injection
computer is in fact sending
signals (absence of faults DF036
No injection multiplex
transmission and DF052
Multiplex network).
If the fault is still present, run
fault finding on the injection
computer (see 13B, Diesel
injection or 17B, Petrol
injection). ET019:EngineSTOPPED
Other possibilities
depending on the
operating status of the
engine:
RUNNING
- UNDER STARTER
- STALLED
Page 79 of 115
37B-79
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
SUB-FUNCTION: AUTOMATIC APPLICATION (CONTINUED 1)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, check that the
multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay and
notesFault finding
4Wheel speedsPR012:Vehicle speedX = 0 mph (km/h)In the event of a fault on this
parameter, check that the anti-
lock braking system computer
is sending the signal correctly
(absence of faults DF037 No
ABS multiplex signal and
DF052 Multiplex network). If
the fault is still present, run
fault finding on the anti-lock
braking system computer (see
38C, Anti-lock braking
system).
5Electronic
parking brakeET011:Parking brakeNo movement of the lever:
INACTIVE
When released: Released
(while releasing, then
INACTIVE).
When applying the brake:
STATUS 1 Static braking
During emergency braking:
STATUS 2 Dynamic braking
(over 6 mph (10 km/h)).
When the system is faulty:
DEFECTIVEIf the status does not operate
as specified, refer to the
interpretation of fault DF043
Parking brake motor.
Page 80 of 115
37B-80
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
SUB FUNCTION: AUTOMATIC APPLICATION (CONTINUED 2)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, check that the
multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes:
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay and
notesFault finding
Electronic
parking
brake
(continued)PR005:Force settingIn rest position:
X = 0 N
When applying the brake on a
level surface:
400
pulled for 2 seconds) on a level
surface:
1100
depressing the brake pedal
once when the parking brake
is applied changes the
measured value of the force
(change in the tension of the
brake cables) and the parking
brake may be over-applied.
Interpretation of these
parameters is only valid
without any pressure on the
brake pedal.The difference between the
reference and measured values
must not be more than - 50 N or
+ 100 N. If the measured value
does not reach or exceeds the
reference value (mechanical or
electrical fault with the control), the
electronic parking brake computer
will detect a fault (DF025 Vehicle
movement with maximum
application, DF049 Brake
application or DF050
Mechanical jamming). If one of
these three faults is displayed by
the diagnostic tool, use the
relevant interpretation.
6Vehicle
inclinePR004:Measured
force valueOn horizontal ground the value
is:
-2d°
the slope:
-25d°
the interpretation of parameter
PR003 Slope value PR003: Slope value