Fault finding – Fault summary table
Tool faultAssociated
DTCDiagnostic tool title
DF003 50C3Computer
DF004 50CAComputer
DF006 50C5Computer configuration
DF015 5166Clutch position sensor circuit
DF016 50 CBWarning light circuit
DF025 5168Vehicle movement with maximum application
DF028 517EComputer
DF029 517BComputer
DF035 5170Undervoltage
DF036 5180No injection multiplex signal
DF037 5181No ABS system multiplex signal
DF038 5188No automatic transmission multiplex signal
DF039 5183No UCH multiplex signal
DF041 5160Angle sensor (internal)
DF042 5161Force sensor (internal)
DF043 5162Parking brake motor
DF044 516CBrake switch
DF045 5172Redundant brake switch
DF046 516FBrake motor/cables connection
DF047 5171Manual control
DF048 5173Release switch
DF049 5175Braking
DF050 5178Mechanical jamming (internal)
DF051 5176System fault after computer replacement
DF052 516DMultiplex network
DF054 50C1Battery overvoltage
DF055 50C0Battery voltage too low
DF056 5163Brake cables incorrectly fitted
DF057 517AComputer internal temperature sensor
DF058 5177Parking brake motor current (internal)
DF059 5194No Protection and Switching Unit multiplex signal
DF073 5174Computer
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
MR-372-J84-37B000$432.mif
Page 25 of 115
37B-25
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults37B
DF025
PRESENT
OR
STOREDVEHICLE MOVEMENT WITH MAXIMUM APPLICATION
1. DEF: Rear wheel movement with parking brake applied
2. DEF: Front wheel movement with parking brake applied
NOTESPriorities when dealing with a number of faults:
First deal with faults DF046 Brake motor/cables connection, DF042 Force sensor,
DF035 Undervoltage, DF041 Slope sensor, DF049 Brake application, DF054
Battery voltage too high and DF055 Battery undervoltage, if they are present or
stored.
If none of these faults is present or stored, the parking brake computer is not normally
the cause.
Conditions for applying the fault finding procedure to a stored fault:
Apply the fault finding procedure even if the fault is stored.
Note:
The fault does not remain present after it has been detected.
1. DEF
NOTESSpecial notes:
– This fault indicates that the electronic parking brake
computer detected rear wheel movement although the
parking brake was applied with maximum force.
– It may be associated with 2.DEF.
If this fault is not associated with the faults mentioned
above, check the conformity of the parking brake's
mechanical force line:
– Condition and conformity of rear brake pads.
– Parking brake cables correctly fitted.
– Good condition of the parking brake cables (no seizing
or deterioration).
– Conformity, condition and correct operation of the rear
brake callipers.
This fault is an operational warning. Check the context in
which it appears.
It may appear during:
– incorrect use of a roller test bench which drives the
rear wheels (MOT test),
– forced assisted release when starting, when the
starting conditions have not been met,
– vehicle overload on a very steep slope (maximum
permissible all-up weight exceeded + angle > 18°: e.g.
towing a trailer or a caravan).
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0D_DF025/FPA_V11_DF025
FPA
Vdiag No.: 0D, 11
Page 27 of 115
37B-27
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults37B
DF025
PRESENT
OR
STOREDVEHICLE MOVEMENT WITH MAXIMUM APPLICATION
1. DEF: The computer has detected vehicle movement when parked (parking brake
applied)
NOTESPriorities when dealing with a number of faults:
First deal with faults DF046 Brake motor/cables connection, DF042 Force sensor,
DF035 Undervoltage, DF041 Slope sensor, DF049 Brake application, DF054
Battery voltage too high and DF055 Battery undervoltage, if they are present or
stored.
If none of these faults is present or stored, the parking brake computer is not normally
the cause.
Conditions for applying the fault finding procedure to a stored fault:
Apply the fault finding procedure even if the fault is stored.
Note:
The fault does not remain present after it has been detected.
Special notes:
– this fault indicates that the electronic parking brake computer detected movement
of the vehicle although the parking brake was applied.
– if this fault is present, with the ignition on, the buzzer on the instrument panel is
activated (when the vehicle is moving with the parking brake applied).
This fault is an operational warning. Check the context in which it appears.
It may appear during:
– an application request, whilst the vehicle is still being driven,
– forced assisted release when starting, when the starting conditions have not
been met,
– parked on a steep slope with slippery surface,
– incorrect use of a roller test bench (MOT test).
Only for Vdiag 08 and 0C:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction section.
If the fault is stored and PR018 = 0 and PR022 > 25, clear the fault: do not take this
fault into account.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF025/FPA_V04_DF025/FPA_V08_DF025
FPA
Vdiag No.: 0C, 04, 08
Page 54 of 115
37B-54
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults37B
DF049
PRESENT
OR
STOREDBRAKING
1. DEF: Inconsistent braking value
2. DEF: Normal brake application value not reached
3. DEF: Normal brake release value not reached
4. DEF: Insufficient braking force
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– a braking command is issued on a slope.
Priorities when dealing with a number of faults:
Deal with faults: DF046 Brake motor / cables connection, DF050 Mechanical
seizure, DF035 Undervoltage, DF058 Parking brake motor current and DF055
Battery undervoltage first if they are present or stored.
Check that the parking brake mechanical tensioning line is correct:
– that the parking brake cables are fitted correctly (refer to the repair procedure),
– that the parking brake cables are in good condition (not seized or deteriorated),
– that the rear brake callipers are correct, in good condition and operating correctly,
– that the rear brake pads are correct and in good condition.
Carry out the necessary repairs.
Using the diagnostic tool statuses screen, display parameter PR003 Slope value.
If the value displayed is not 0 degrees (± 1) on level ground, carry out slope initialisation again (actuator control
mode menu).
Using the diagnostic tool parameters screen, display the following parameters: PR005 Force setpoint and PR004
Measured force value. These must show the various values recorded in the conformity check.
Clear the fault, switch off the ignition for 5 minutes (vehicle doors and windows closed), switch the ignition back
on and repeat a braking command on a slope.
If the fault reappears, switch off the ignition and disconnect the computer supply fuse (fuse F23 of the engine fuse
box, refer to the wiring diagram) for approximately 1 minute.
Reconnect the fuse, switch the ignition on and establish dialogue with the computer. Apply the brake to check
whether the fault recurs.
If the fault reappears despite the above tests, or if the parameter values are not within conformity check
tolerances while the brake is applied, then contact your Techline.
AFTER REPAIRClear the fault memory.
Follow the instructions to confirm repair.
If the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other possible faults.
FPA
Vdiag No.: 04
FPA_V04_DF049
Page 55 of 115
37B-55
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults37B
DF049
PRESENT
OR
STOREDBRAKING
1. DEF: Inconsistent braking value
2. DEF: Normal brake application value not reached
3. DEF: Normal brake release value not reached
4. DEF: Insufficient braking force
NOTESPriorities when dealing with a number of faults:
Deal first with faults DF003 (1.DEF; 2.DEF), DF004, DF028, DF029, DF041, DF042,
DF043, DF050, DF055, DF057, DF058 and DF073.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the ignition is switched on (forced + after ignition
feed, see Introduction) and an application request on a slope.
1. DEF
NOTESSpecial notes:
The 1.DEF code indicates an inconsistency between the
measured force value (PR004) and the parking brake status
(ET030: Electronic parking brake operation when there
is a fault in the fault context).
This fault can appear after disconnecting the battery
(parking brake applied).
Check the context of the fault when the fault appears:
If ET030 is S TAT U S 5 , S TAT U S 6 , S TAT U S 7 , S TAT U S 8 , S TAT U S 9 o r S TAT U S 1 0 and if PR004 is greater than
450 N and if PR012 Vehicle speed is 0 mph (0 km/h) when the fault appears:
– check to see if the battery has been disconnected, if it has, the appearance of this fault is normal, clear the
fault,
– if not, check the computer supply voltage and the battery.
Repair if necessary.
If the fault persists, contact the Techline.
If ET030 is S TAT U S 5 , S TAT U S 6 , S TAT U S 7 and if PR004 is less than 450 N and if PR012 Vehicle speed is
less than 3 mph (5 km/h) when the fault appears:
– Check for traces of heating on the brakes:
– Check that the pads have returned correctly to the rest position.
– Check that the small lever has sufficient return force.
– Check that there is no friction or points of resistance on the cables.
– If there is no indication of any defective operation of these components and if PR019 < 3 and PR022 >
25 and PR018 < 15, then clear the fault.
– If not, contact the Techline.
If the fault is still present, contact the Techline.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF049/FPA_V08_DF049/FPA_V0D_DF049/FPA_V11_DF049
FPA
Vdiag No.: 0C, 08, 0D,
11
Page 56 of 115
37B-56
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults37B
DF049
CONTINUED 1
2. DEF
NOTESSpecial notes:
The specification 2.DEF mainly comes from a fault with the
electrical power supply, braking application travel or the
internal force sensor.
If this fault appears after the parking brake has been replaced:
– Check the conformity of the parking brake fitting.
– Check that the battery voltage PR001 is greater than 12.5 V.
– Clear the fault and restart the procedure for fitting the parking brake: see Replacement of components.
Check the fault context when the fault appears: if the battery voltage PR001 is less than 9 V when the fault
appears, then:
– Check the supply line and that the resistance is less than 150 m.
– If there is no sign of a fault on the supply line and if PR019 < 3 and PR022 > 25 and PR018 < 15 then clear
the fault.
Check the fault context when the fault appears: If ET028 Brake switch signal is PRESSED, then:
–If PR019 < 3 and PR022 > 25 and PR018 < 15, then clear the fault.
– The fault can be caused when the user depresses the brake pedal hard, when the parking brake is being
applied. If this is the case, clear the fault.
If there is a loud noise when applying, when maximum braking is requested, then the cause may be mechanical.
Check that the parking brake mechanical tensioning line is correct:
– Parking brake cables correctly fitted.
– Good condition of the parking brake cables (no seizing or deterioration).
– Conformity, condition and proper functioning of the rear brake callipers.
– Condition and conformity of rear brake pads.
– Conformity of rear brakes bleeding.
Carry out the necessary repairs.
Using the diagnostic tool (PARKING sub-function), display the parameters PR005 Force setpoint and PR004
Measured force value. These must have the various values recorded in the conformity check.
If the fault is still present, contact the Techline.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA
Vdiag No.: 0C, 08, 0D,
11
Page 57 of 115
37B-57
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults37B
DF049
CONTINUED 2
3. DEF
4. DEF
NOTESSpecial notes:
The specification 3.DEF mainly comes from a fault with the
electrical power supply or the internal force sensor.
The 4.DEF code is mainly generated by an electrical supply
fault or an internal fault (motor, sensor, etc.). It indicates that
the parking brake is neither applied or released.
If the fault persists, contact the Techline.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA
Vdiag No.: 0C, 08, 0D,
11
Page 63 of 115
37B-63
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF055
PRESENT
OR
STOREDBATTERY UNDERVOLTAGE
1. DEF: Battery voltage too low
2. DEF: Electronic parking brake reset when vehicle being driven
1. DEF
NOTESSpecial notes:
The fault does not usually come from the electronic parking
brake computer.
This fault appears as present if the computer supply voltage
is less than 10.3 V, and becomes stored once the voltage
rises back above 10.5 V.
Only for Vdiag 08, 0C and 0D:
If there is a stored fault, refer to the statuses and
parameters when it appears.
Explanation of counters: see Introduction.
If the fault is stored and PR018 = 0 and PR022 > 25,
clear the fault:
do not take this fault into account.
Note:
This fault may appear if starting is very difficult.
Conditions for applying the fault finding procedure to
a stored fault:
Apply this fault finding procedure if the fault reappears as
present after the ignition has been switched on (forced
+ after ignition feed, see Introduction).
2. DEF
NOTESNote:
This fault only affects Vdiag 0D.
Priorities when dealing with a number of faults:
Deal first with faults DF046 Brake motor/cables
connection, DF042 Force sensor, DF035 Undervoltage,
DF041 Slope sensor, DF049 Brake application, DF054
Battery voltage too high and DF055 Battery
undervoltage if they are present or stored.
If none of these faults is present or stored, the parking brake
computer is not normally the cause.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF055/FPA_V04_DF055/FPA_V08_DF055/FPA_V0D_DF055/FPA_V11_DF055
Page 72 of 115
37B-72
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
MAIN SCREEN (CONTINUED 1)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, make sure that
the multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay and
notesFault finding
3Electronic
parking brakePR005: Force setting In rest position:
X = 0 N
When applying the brake
on a level surface:
400 < X < 550 N
When fully applied (lever
fully pulled for 2 seconds)
on a level surface:
1100 < X < 1150 N
Note: depressing the
brake pedal once when
the parking brake is
applied changes the
measured force value
(change in the tension of
the brake cables) and the
parking brake may be
over-applied.
Interpretation of these
parameters is only valid
without any pressure on
the brake pedal.The difference between the
reference and measured
values must not be more than
-50 N or + 100 N. If the
measured value does not
reach or exceeds the reference
value (mechanical or electrical
fault with the control), the
electronic parking brake
computer will detect a fault
(DF025 Vehicle movement
with maximum application,
DF049 Brake application or
DF050 Mechanical jamming).
If one of these three faults is
displayed by the diagnostic
tool, use the relevant
interpretation. PR004:Measured force
value
Page 76 of 115
37B-76
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
SUB-FUNCTION: PARKING (CONTINUED 2)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, make sure that
the multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay
and notesFault finding
3Parking brake
assistPR005:Force setting In rest position:
X = 0 N
When applying the brake
on a level surface:
400 < X < 550 N
When fully applied (lever
fully pulled for 2 seconds)
on a level surface:
1100 < X < 1150 N
Note: depressing the
brake pedal once when
the parking brake is
applied changes the
measured force value
(change in the tension of
the brake cables) and the
parking brake may be
over-applied.
Interpretation of these
parameters is only
valid without any
pressure on the brake
pedal.The difference between the
reference and measured
values must not be more than
-50 N or + 100 N.
If the measured value does not
reach or exceeds the reference
value (mechanical or electrical
fault with the control), the
electronic parking brake
computer will detect a fault
(DF025 Vehicle movement
with maximum application,
DF049 Brake application or
DF050 Mechanical jamming).
If one of these three faults is
displayed by the diagnostic
tool, use the relevant
interpretation. PR004:Measured force