wiring RENAULT TWINGO 2009 2.G Air Conditioning User Guide
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: TWINGO, Model: RENAULT TWINGO 2009 2.GPages: 122
Page 63 of 122

61A-60
HEATING
Passenger compartment fan assembly control unit: Removal - Refitting
LEFT-HAND DRIVE
61A
aDisconnect the connector (8) from the blower unit
control unit on the right-hand side.
aMove aside the blower unit control unit wiring har-
ness (9) .aRemove:
-the blower unit control unit bolts (10) ,
-the blower unit control unit (11) .
REFITTING
I - REFITTING OPERATION FOR PART 
CONCERNED
aRefit:
-the blower unit control unit,
-the bolts to the blower unit control unit.
aFit the wiring harness on the blower unit control unit.
aConnect the blower unit control unit connector.
aRefit:
-the blower unit control unit,
-the bolts to the blower unit control unit. AIR CONDITIONING or STANDARD HEATING
121170
121169
119714
AIR CONDITIONING or STANDARD HEATING
CLIMATE CONTROL 
Page 66 of 122

61A-63
HEATING
Passenger compartment fan assembly control unit: Removal - Refitting
RIGHT-HAND DRIVE
61A
II -  REMOVAL OPERATION FOR PART 
CONCERNED
aDisconnect the connector (3) from the blower unit
control unit on the left-hand side.
aRemove:
-the blower unit control unit bolts (4) ,
-the blower unit control unit.aDisconnect the connector (5) from the blower unit
control unit on the right-hand side.
aMove the electrical wiring (6) away from the fan as-
sembly control unit. CLIMATE CONTROL
124100
AIR CONDITIONING or STANDARD HEATING
124101
121169 
Page 67 of 122

61A-64
HEATING
Passenger compartment fan assembly control unit: Removal - Refitting
RIGHT-HAND DRIVE
61A
aRemove:
-the blower unit control unit bolts (7) ,
-the blower unit control unit (8) .
REFITTING
I - REFITTING OPERATION FOR PART 
CONCERNED
aRefit:
-the blower unit control unit,
-the bolts to the blower unit control unit.
aFit the fan assembly control unit electrical wiring.
aConnect the blower unit control unit connector.
aRefit:
-the blower unit control unit,
-the bolts to the blower unit control unit.aConnect the blower unit control unit connector.
II -  FINAL OPERATION.
aConnect the hazard warning lights switch connector.
aClip on the "trim - air vent" assembly.
aRefit the instrument panel (see Instrument panel:
Removal - Refitting) (MR 411, 83A, Instrument
panel).
aRefit the passenger's front airbag (see Passenger's
frontal airbag: Removal - Refitting) (MR 411, 88C,
Airbags and seat belt pretensioners).
aClip on the upper storage compartment on the driv-
er’s side.
aConnect the battery (see  ) (MR 411, 80A, Battery).
aUnlock the airbag computer using the Diagnostic
tool (see Fault finding - Replacement of compo-
nents) (MR 413, 88C, Airbags and pretensioners).
124100
AIR CONDITIONING or STANDARD HEATING
CLIMATE CONTROL
AIR CONDITIONING or STANDARD HEATING
AIR CONDITIONING or STANDARD HEATING 
Page 122 of 122

62A-41
AIR CONDITIONING
Exterior air temperature sensor: Removal - Refitting
62A
REMOVAL
I - REMOVAL PREPARATION OPERATION
aRemove:
-the right-hand door mirror glass (see Door mirror
glass: Removal - Refitting) (MR 412, 56A, Exteri-
or equipment),
-the right-hand door mirror cover (see Door mirror
casing: Removal - Refitting) (MR 412, 56A, Exte-
rior equipment).
II -  OPERATION FOR REMOVAL OF PART 
CONCERNED
aUnclip the exterior air temperature sensor from its
mounting using a flat-blade screwdriver.
aCut the exterior air temperature sensor wires (see
Wiring: Repair) (Technical Note 6015A, 88A, Wir-
ing).
REFITTING
I - REFITTING OPERATION FOR PART 
CONCERNED
aSolder the exterior air temperature sensor feed
wires (see Wiring: Repair) (Technical Note 6015A,
88A, Wiring).
aClip the external air temperature sensor onto its sup-
port.II -  FINAL OPERATION.
aRefit:
-the right-hand door mirror cover (see Door mirror
casing: Removal - Refitting) (MR 412, 56A, Exte-
rior equipment),
-the right-hand door mirror glass (see Door mirror
glass: Removal - Refitting) (MR 412, 56A, Exteri-
or equipment).
101624