83A-50
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V5 MR-413-X44-83A000$952.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart Vdiag No.: 04, 0883A
Vdiag No.: 04 08
ALP 1
CONTINUED 1
VEHICLE CHECK
Check the cleanliness and condition of the contacts of the diagnostic socket,
component code 225 connected to the vehicle.
Check the condition of the cable from the diagnostic socket to the sensor and the
cleanliness and condition of the connections.
Check the sensor connections.
Check the condition of the cable from the sensor to the CLIP tool and the cleanliness
and condition of the connections.
Check the cleanliness and condition of the CLIP socket.
If the connector or connectors are faulty and if there is a repair procedure (see
Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the connector, otherwise replace the wiring.
If the fault is still present, contact Techline.
Check the condition and connection of the instrument panel connector, component
code 247.
If the connector is faulty and there is a repair method (see Technical Note 6015A,
Repairing electrical wiring, Wiring: Precautions for repair), repair the connector,
otherwise replace the wiring.
Check instrument panel supply fuse MIN (5 A), component code 247 on the passenger
compartment fuse box, component code 1016 and the condition and cleanliness of
the contacts.
Check the instrument panel after ignition supply fuse MIN (15 A), component code
247 on the passenger compartment fuse box, component code 1016, and the
condition and cleanliness of the contacts.