21B-33
MR-413-X44-21B000$413.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No.: 04
21B
DF067
PRESENT
OR
STOREDLEVER POSITION SWITCH CIRCUIT
CC.0: Short circuit to earth
CO.1: Open circuit or short circuit to + 12 V
1.DEF: Values outside the limits
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the ignition is switched on or the engine is started.
Use the Wiring Diagrams Technical Note for New TWINGO.
Check the connection and condition of the connectors of components 1058 and 119.
If the connectors are faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the connectors; otherwise, replace the wiring.
Check the continuity and insulation to earth and + 12 V on the following connections:
●Connection code 5FJ,
●Connection code 5FK,
●Connection code 5FM,
●Connection code 5FL,
●Connection code 5FI,
between components 1058 and 119.
If the connections are faulty, check the connection and condition of intermediate connector R107 located under
the dashboard and intermediate connector R67 located near the engine fuse and relay box.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the wiring, otherwise replace it.
If the wiring harness is correct, apply the fault finding procedure associated with the statuses: ET043 Lever
switch No. 0, ET044 Lever switch No. 1, ET045 Lever switch No. 2 and ET046 Lever switch No. 3 (see
Interpretation of statuses).
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF067