Page  60   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
  For special national conditions, see Annex ZB.  
1   Add   the following note:  
NOTE Z1  The use of certain substances in electrical and electronic 
equipment is restricted   within the EU: see Directive 2011/65/EU.     P  
4.Z1   Add   the following new subclause after 4.9:  
To protect against excessive current, short - circuits and 
earth faults in circuits connected to an a.c.  mains , 
protective devices shall be included either as integ ral 
parts of the equipment or as parts of the building 
installation, subject to the following, a), b) and c):  
a) except as detailed in b) and c), protective devices 
necessary to comply with the requirements of B.3.1 and 
B.4 shall be included as parts of th e equipment;  
b) for components in series with the mains input to the 
equipment such as the supply cord, appliance coupler, 
r.f.i. filter and switch, short - circuit and earth fault 
protection may be provided by protective devices in the 
building installation ;  
c) it is permitted for  pluggable equipment type B   or 
permanently connected equipment , to rely on 
dedicated overcurrent and short - circuit protection in the 
building installation, provided that the means of 
protection, e.g. fuses or circuit breakers, is fu lly 
specified in the installation instructions.  
If reliance is placed on protection in the building 
installation, the installation instructions shall so state, 
except that for  pluggable equipment type A   the 
building installation shall be regarded as provid ing 
protection in accordance with the rating of the wall 
socket outlet.     N/A  
5.4.2.3.2.4   Add   the following to the end of this subclause:  
The requirement for interconnection with  external 
circuit   is in addition given in EN 50491 - 3:2009.     N/A  
10.2.1   Add th e following to  c)
  and  d)
  in table 39:  
For additional requirements, see 10.5.1.     N/A   
Page 70 of 406

   
 
Page  65   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 5.5.6   Finland, Norway  and   Sweden  
To the end of the subclause the following is added:  
Resistors used as  basic safeguard   or bridging  basic 
insulation   in  class I pluggable equipment   type A  
shall comply w ith G.10.1 and the test of G.10.2.     N/A  
5.6.1   Denmark  
Add   to the end of the subclause  
Due to many existing installations where the socket -
outlets can be protected with fuses with higher rating 
than the rating of the socket - outlets the protection for 
plugg able equipment type A shall be an integral part of 
the equipment.  
Justification:  
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse.     N/A  
5.6.4.2.1   Ireland and United Kingdom  
After the indent for  pluggable equipment type A , the 
foll owing is added:  
–   the  protective current rating   is taken to be 13 A, this 
being the largest rating of fuse used in the  mains   plug.     N/A  
5.6.5.1   To the second paragraph the following is added:  
The range of conductor sizes of flexible cords to be 
accepted b y terminals for equipment with a rated 
current over 10 A and up to and including 13 A is:  
1,25 mm 2
  to 1,5 mm 2
  in cross - sectional area.     N/A  
5.7.5   Denmark  
To the end of the subclause the following is added:  
The installation instruction shall be affixed to  the 
equipment if the  protective conductor current  
exceeds the limits of 3,5 mA a.c. or 10 mA d.c.     N/A   
Page 85 of 406

   
 
Page  80   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
5  
Modification to 4.Z1  
N /A  
4.Z1   Add  the following new subclause after 4.9:  
 
To protect against excessive current, short - circuits 
and earth faults in circuits connected to an a.c. 
mains , protective devices shall be included either as 
integral parts of the equipment or as parts of   the 
building installation, subject to the following, a), b) 
and c):  
a) except as detailed in b) and c), protective devices 
necessary to comply with the requirements of B.3.1 
and B.4 shall be included as parts of the equipment;  
b) for components in series  with the mains input to 
the equipment such as the supply cord, appliance 
coupler, r.f.i. filter and switch, short - circuit and earth 
fault protection may be provided by protective 
devices in the building installation;  
c) it is permitted for  pluggable equipm ent type B  or 
permanently connected equipment , to rely on 
dedicated overcurrent and short - circuit protection in 
the building installation, provided that the means of 
protection, e.g. fuses or circuit breakers, is fully 
specified in the installation instruc tions.  
 
If reliance is placed on protection in the building 
installation, the installation instructions shall so state, 
except that for  pluggable equipment type A  the 
building installation shall be regarded as providing 
protection in accordance with the ra ting of the wall 
socket outlet.     N/A  
6  
Modification to 5.4.2.3.2.4  
N/A  
5.4.2.3.2.4   Add  the following to the end of this subclause:  
 
The requirement for interconnection with  external 
circuit   is in addition given in EN 50491 - 3:2009.     N/A  
7  
Modification to   10.2.1  
N/A  
10.2.1  
Add the following to  c)
  and  d)
  in table 39:  
 
For additional requirements, see 10.5.1.     N/A   
Page 89 of 406

   
 
Page  84   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TRF No.  IEC62368_1 C    
   
A   capacitor classified Y3 according to EN 60384 -
14:2005, may bridge this insulation under  
the following conditions:  
 
•    the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by EN 
60384 - 14, which in addition to the Y3 tes ting, is 
tested with an impulse test of 2,5 kV defined in 
5.4.11;  
 
•   the additional testing shall be performed on all the 
test specimens as described in EN 60384 - 14;  
 
the impulse test of 2,5 kV is to be performed before 
the endurance test in EN 60384 - 14,   in the sequence 
of tests as described in EN 60384 - 14.  
5.5.2.1   Norway  
 
After the 3rd paragraph the following is added:  
 
Due to the IT power system used, capacitors are 
required to be rated for the applicable line - to - line 
voltage (230 V).     N/A  
5.5.6   Finland, Norway  and  Sweden  
 
To the end of the subclause the following is added:  
 
Resistors used as  basic safeguard  or bridging 
basic insulation  in  class I pluggable equipment 
type A  shall comply with G.10.1 and the test of 
G.10.2.     N/A  
5.6.1   Denmark  
 
Add  to the end of the subclause  
Due to many existing installations where the socket -
outlets can be protected with fuses  
with higher rating than the rating of the socket -
outlets the protection for pluggable  
equipment type A shall be an integral part of the 
equi pment.  
Justification:  
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse.     N/A  
5.6.4.2.1   Ireland and United Kingdom  
 
After the indent for  pluggable equipment type A , 
the following is added:  
–   the  protective current rating  is taken t o be 13 A, 
this being the largest rating of fuse used in the 
mains  plug.     N/A   
Page 169 of 406

   
 
Page  59   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
  For special national conditions, see Annex ZB.  
1   Add   the following note:  
NOTE Z1  The use of certain substances in electrical and electronic 
equipment is restricted within the EU: see Directive 2011/65/EU.     P  
4.Z1   Add   the following new subclause after 4.9:  
To protect against excessive current, short - circuits and 
earth faults in circuits connected to an a.c.  mains , 
protective devices shall be included either as integral 
parts of the equipment or as parts of the building 
installation, subject to the following, a), b) and c):  
a) except as detailed in b) and c), protective devices 
necessary to comply with the requirements of B.3.1 and 
B.4 shall be included as parts of the equipment;  
b) for components in series with the mains   input to the 
equipment such as the supply cord, appliance coupler, 
r.f.i. filter and switch, short - circuit and earth fault 
protection may be provided by protective devices in the 
building installation;  
c) it is permitted for  pluggable equipment type B   or 
permanently connected equipment , to rely on 
dedicated overcurrent and short - circuit protection in the 
building installation, provided that the means of 
protection, e.g. fuses or circuit breakers, is fully 
specified in the installation instructions.  
If reli ance is placed on protection in the building 
installation, the installation instructions shall so state, 
except that for  pluggable equipment type A   the 
building installation shall be regarded as providing 
protection in accordance with the rating of the wal l 
socket outlet.     N/A  
5.4.2.3.2.4   Add   the following to the end of this subclause:  
The requirement for interconnection with  external 
circuit   is in addition given in EN 50491 - 3:2009.     N/A  
10.2.1   Add the following to  c)
  and  d)
  in table 39:  
For additional re quirements, see 10.5.1.     N/A   
Page 174 of 406

   
 
Page  64   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 5.5.6   Finland, Norway  and   Sweden  
To the end of the subclause the following is added:  
Resistors used as  basic safeguard   or bridging  basic 
insulation   in  class I pluggable equipment   type A  
shall comply with G.10. 1 and the test of G.10.2.     N/A  
5.6.1   Denmark  
Add   to the end of the subclause  
Due to many existing installations where the socket -
outlets can be protected with fuses with higher rating 
than the rating of the socket - outlets the protection for 
pluggable equi pment type A shall be an integral part of 
the equipment.  
Justification:  
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse.     N/A  
5.6.4.2.1   Ireland and United Kingdom  
After the indent for  pluggable equipment type A , the 
following is  added:  
–   the  protective current rating   is taken to be 13 A, this 
being the largest rating of fuse used in the  mains   plug.     N/A  
5.6.5.1   To the second paragraph the following is added:  
The range of conductor sizes of flexible cords to be 
accepted by termina ls for equipment with a rated 
current over 10 A and up to and including 13 A is:  
1,25 mm 2
  to 1,5 mm 2
  in cross - sectional area.     N/A  
5.7.5   Denmark  
To the end of the subclause the following is added:  
The installation instruction shall be affixed to the 
equip ment if the  protective conductor current  
exceeds the limits of 3,5 mA a.c. or 10 mA d.c.     N/A   
Page 189 of 406

   
 
Page  79   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
5  
Modification to 4.Z1  
N /A  
4.Z1   Add  the following new subclause after 4.9:  
 
To protect against excessive current, short - circuits 
and earth faults in circuits connected to an a.c. 
mains , protective devices shall be included either as 
integral parts of the equipment or as parts of   the 
building installation, subject to the following, a), b) 
and c):  
a) except as detailed in b) and c), protective devices 
necessary to comply with the requirements of B.3.1 
and B.4 shall be included as parts of the equipment;  
b) for components in series  with the mains input to 
the equipment such as the supply cord, appliance 
coupler, r.f.i. filter and switch, short - circuit and earth 
fault protection may be provided by protective 
devices in the building installation;  
c) it is permitted for  pluggable equipm ent type B  or 
permanently connected equipment , to rely on 
dedicated overcurrent and short - circuit protection in 
the building installation, provided that the means of 
protection, e.g. fuses or circuit breakers, is fully 
specified in the installation instruc tions.  
 
If reliance is placed on protection in the building 
installation, the installation instructions shall so state, 
except that for  pluggable equipment type A  the 
building installation shall be regarded as providing 
protection in accordance with the ra ting of the wall 
socket outlet.     N/A  
6  
Modification to 5.4.2.3.2.4  
N/A  
5.4.2.3.2.4   Add  the following to the end of this subclause:  
 
The requirement for interconnection with  external 
circuit   is in addition given in EN 50491 - 3:2009.     N/A  
7  
Modification to   10.2.1  
N/A  
10.2.1  
Add the following to  c)
  and  d)
  in table 39:  
 
For additional requirements, see 10.5.1.     N/A   
Page 193 of 406

   
 
Page  83   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TRF No.  IEC62368_1 C    
   
A   capacitor classified Y3 according to EN 60384 -
14:2005, may bridge this insulation under  
the following conditions:  
 
•    the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by EN 
60384 - 14, which in addition to the Y3 tes ting, is 
tested with an impulse test of 2,5 kV defined in 
5.4.11;  
 
•   the additional testing shall be performed on all the 
test specimens as described in EN 60384 - 14;  
 
the impulse test of 2,5 kV is to be performed before 
the endurance test in EN 60384 - 14,   in the sequence 
of tests as described in EN 60384 - 14.  
5.5.2.1   Norway  
 
After the 3rd paragraph the following is added:  
 
Due to the IT power system used, capacitors are 
required to be rated for the applicable line - to - line 
voltage (230 V).     N/A  
5.5.6   Finland, Norway  and  Sweden  
 
To the end of the subclause the following is added:  
 
Resistors used as  basic safeguard  or bridging 
basic insulation  in  class I pluggable equipment 
type A  shall comply with G.10.1 and the test of 
G.10.2.     N/A  
5.6.1   Denmark  
 
Add  to the end of the subclause  
Due to many existing installations where the socket -
outlets can be protected with fuses  
with higher rating than the rating of the socket -
outlets the protection for pluggable  
equipment type A shall be an integral part of the 
equi pment.  
Justification:  
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse.     N/A  
5.6.4.2.1   Ireland and United Kingdom  
 
After the indent for  pluggable equipment type A , 
the following is added:  
–   the  protective current rating  is taken t o be 13 A, 
this being the largest rating of fuse used in the 
mains  plug.     N/A   
Page 271 of 406

   
 
Page  58   of  88   Report No. :  60404489 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
  For special national conditions, see Annex ZB.  
1   Add   the following note:  
NOTE Z1  The use of certain substances in electrical and electronic 
equipment is restricted within the EU: see Directive 2011/65/EU.     P  
4.Z1   Add   the following ne w subclause after 4.9:  
To protect against excessive current, short - circuits and 
earth faults in circuits connected to an a.c.  mains , 
protective devices shall be included either as integral 
parts of the equipment or as parts of the building 
installation, su bject to the following, a), b) and c):  
a) except as detailed in b) and c), protective devices 
necessary to comply with the requirements of B.3.1 and 
B.4 shall be included as parts of the equipment;  
b) for components in series with the mains input to the 
eq uipment such as the supply cord, appliance coupler, 
r.f.i. filter and switch, short - circuit and earth fault 
protection may be provided by protective devices in the 
building installation;  
c) it is permitted for  pluggable equipment type B   or 
permanently conn ected equipment , to rely on 
dedicated overcurrent and short - circuit protection in the 
building installation, provided that the means of 
protection, e.g. fuses or circuit breakers, is fully 
specified in the installation instructions.  
If reliance is placed o n protection in the building 
installation, the installation instructions shall so state, 
except that for  pluggable equipment type A   the 
building installation shall be regarded as providing 
protection in accordance with the rating of the wall 
socket outlet.     N/A  
5.4.2.3.2.4   Add   the following to the end of this subclause:  
The requirement for interconnection with  external 
circuit   is in addition given in EN 50491 - 3:2009.     N/A  
10.2.1   Add the following to  c)
  and  d)
  in table 39:  
For additional requirements, see  10.5.1.     N/A   
Page 276 of 406

   
 
Page  63   of  88   Report No. :  60404489 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 5.5.6   Finland, Norway  and   Sweden  
To the end of the subclause the following is added:  
Resistors used as  basic safeguard   or bridging  basic 
insulation   in  class I pluggable equipment   type A  
shall comply with G.10.1 and the  test of G.10.2.     N/A  
5.6.1   Denmark  
Add   to the end of the subclause  
Due to many existing installations where the socket -
outlets can be protected with fuses with higher rating 
than the rating of the socket - outlets the protection for 
pluggable equipment type   A shall be an integral part of 
the equipment.  
Justification:  
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse.     N/A  
5.6.4.2.1   Ireland and United Kingdom  
After the indent for  pluggable equipment type A , the 
following is added:  
–   t he  protective current rating   is taken to be 13 A, this 
being the largest rating of fuse used in the  mains   plug.     N/A  
5.6.5.1   To the second paragraph the following is added:  
The range of conductor sizes of flexible cords to be 
accepted by terminals for equ ipment with a rated 
current over 10 A and up to and including 13 A is:  
1,25 mm 2
  to 1,5 mm 2
  in cross - sectional area.     N/A  
5.7.5   Denmark  
To the end of the subclause the following is added:  
The installation instruction shall be affixed to the 
equipment if th e  protective conductor current  
exceeds the limits of 3,5 mA a.c. or 10 mA d.c.     N/A