Page 28 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
B.3.7 Audio amplifier abnormal operating conditions P
B.3.8 Safeguards functional during and after abnormal
operati ng conditions ................................ .............. : (See appended table B.3) P
B.4 Simulated single fault conditions
P
B.4.1 General P
B.4.2 Temperature controlling device N/A
B.4.3 Blocked motor test (See appended table B. 4 ) N/A
B.4.4 Functional insulation P
B.4.4.1 Sh ort circuit of clearances for functional insulation P
B.4.4.2 Short circuit of creepage distances for functional
insulation P
B.4.4.3 Short circuit of functional insulation on coated
printed boards N/A
B.4.5 Short - circuit and interruption of electrod es in tubes
and semiconductors P
B.4.6 Short circuit or disconnection of passive
components P
B.4.7 Continuous operation of components N/A
B.4.8 Compliance during and after single fault conditions
................................ ................................ ............... : (See appended table B.4) P
B.4.9 Battery charging and discharging under single fault
conditions Battery is not provided N/A
C UV RADIATION
N/A
C.1 Protection of materials in equipment from UV radiation
N/A
C.1.2 Requirements N/A
C.1.3 Test method N/A
C.2 UV light conditioning test
N/A
C.2.1 Test apparatus ................................ ....................... : N/A
C.2.2 Mounting of test samples N/A
C.2.3 Carbon - arc light - exposure test N/A
C.2.4 Xenon - arc light - exposure test N/A
D TEST GENERATORS
N/A
D.1 Impulse test generators
N/A
D.2 Antenna interface test generator
N/A
D.3 Electronic pul se generator
N/A
Page 281 of 406

Page 68 of 88 Report No. : 60404489 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
ATTACHMENT TO TEST R EPORT
IEC 62368 - 1
EUROPEAN GROUP DIFFE RENCES AND NATIONAL DIFFERENCES
(AUDIO/VIDEO, INFORM ATION AND COMMUNICAT ION TECHNOLOGY EQUIP MENT - PART 1: SAFET Y
REQUIREMENTS)
Differences according to ............... :
EN IEC 62368 - 1:2020+A11:2020
Attachment Form No . ..................... :
EU_GD_IEC62368_1C
Attachment Originator ................... :
UL(Demko)
Master Attachment ......................... :
2020 - 03 - 10
Copyright © 2020 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland . All rights reserved.
CENELEC COMMON MODIFICATIONS (EN)
P
Clause numbers in the cells that are shaded light grey are clause references in EN
IEC 62368 - 1:2020+A11:2020. All other clause numbers in that column, except for
those in the paragraph below, r efers to IEC 62368 - 1:2018.
Clauses, subclauses, notes, tables, figures and annexes which are additional to
those in IEC 62368 - 1:2018 are prefixed “Z”. P
Add the following annexes:
Annex ZA (normative) Normative references to international publications
with their corresponding European publications
Annex ZB (normative) Special national conditions
Annex ZC (informative) A - deviations
Annex ZD (informative) IEC and CENELEC code designations for flexible
cords P
1 Modification to Clause 3 .
N/A
3.3.19 Sound exposure
Replace 3.3.19 of IEC 62368 - 1 with the following definitions: N/A
3.3.19.1
momentary exposure level, MEL
metric for estimating 1 s sound exposure level from
the HD 483 - 1 S2 test signal applied to both channels,
based on EN 50332 - 1: 2013, 4.2.
Note 1 to entry: MEL is measured as A - weighted levels in dB.
Note 2 to entry: See B.3 of EN 50332 - 3:2017 for additional
information. N/A
Page 322 of 406

Page 11 of 88 Report No. : 60404490 001
TR F No. IEC62368_1 C
10 Radiation
Cla ss and Energy Source
(e.g. RS1: PMP sound output) Body Part
(e.g., Ordinary) Safeguards
B S R
RS1:Indicating lights Ordinary N/A N/A N/A
Supplementary Information:
“B” – Basic Safeguard; “S” – Supplementary Safeguard; “R” – Reinforced Safeguard
Page 323 of 406

Page 12 of 88 Report No. : 60404490 001
TR F No. IEC62368_1 C
E NERGY SOURCE DIAGRAM
Optional . Manufacturers are to provide the energy sources diagram identify declared energy sources and
identifying the demarcations are between power sources. Recommend diagram be provided included in
power supply and multipart system s.
Insert diagram below. Example diagram designs are; Block diagrams; image(s) with layered data; mechanical
drawings
■ ES ■ PS ■ MS ■ TS ■ RS
ES Classification:
ES1: All parts .
PS Classification:
PS3: Head unit .
PS2: LCD m odule and Keyboard circuits .
MS classification:
MS1 : There are no sharp edges or corners . Equipment mass is under 7 kg .
TS classification:
TS1: All accessible parts including monitor enclosure, screen surface and keyboard enclosure .
RS classification:
R S1: Indicating lights and low power devices.
Page 339 of 406

Page 28 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
B.3.7 Audio amplifier abnormal operating conditions P
B.3.8 Safeguards functional during and after abnormal
operati ng conditions ................................ .............. : (See appended table B.3) P
B.4 Simulated single fault conditions
P
B.4.1 General P
B.4.2 Temperature controlling device N/A
B.4.3 Blocked motor test (See appended table B. 4 ) N/A
B.4.4 Functional insulation P
B.4.4.1 Sh ort circuit of clearances for functional insulation P
B.4.4.2 Short circuit of creepage distances for functional
insulation P
B.4.4.3 Short circuit of functional insulation on coated
printed boards N/A
B.4.5 Short - circuit and interruption of electrod es in tubes
and semiconductors P
B.4.6 Short circuit or disconnection of passive
components P
B.4.7 Continuous operation of components N/A
B.4.8 Compliance during and after single fault conditions
................................ ................................ ............... : (See appended table B.4) P
B.4.9 Battery charging and discharging under single fault
conditions Battery is not provided N/A
C UV RADIATION
N/A
C.1 Protection of materials in equipment from UV radiation
N/A
C.1.2 Requirements N/A
C.1.3 Test method N/A
C.2 UV light conditioning test
N/A
C.2.1 Test apparatus ................................ ....................... : N/A
C.2.2 Mounting of test samples N/A
C.2.3 Carbon - arc light - exposure test N/A
C.2.4 Xenon - arc light - exposure test N/A
D TEST GENERATORS
N/A
D.1 Impulse test generators
N/A
D.2 Antenna interface test generator
N/A
D.3 Electronic pul se generator
N/A
Page 379 of 406

Page 68 of 88 Report No. : 60404490 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
ATTACHMENT TO TEST R EPORT
IEC 62368 - 1
EUROPEAN GROUP DIFFE RENCES AND NATIONAL DIFFERENCES
(AUDIO/VIDEO, INFORM ATION AND COMMUNICAT ION TECHNOLOGY EQUIP MENT - PART 1: SAFET Y
REQUIREMENTS)
Differences according to ............... :
EN IEC 62368 - 1:2020+A11:2020
Attachment Form No . ..................... :
EU_GD_IEC62368_1C
Attachment Originator ................... :
UL(Demko)
Master Attachment ......................... :
2020 - 03 - 10
Copyright © 2020 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland . All rights reserved.
CENELEC COMMON MODIFICATIONS (EN)
P
Clause numbers in the cells that are shaded light grey are clause references in EN
IEC 62368 - 1:2020+A11:2020. All other clause numbers in that column, except for
those in the paragraph below, r efers to IEC 62368 - 1:2018.
Clauses, subclauses, notes, tables, figures and annexes which are additional to
those in IEC 62368 - 1:2018 are prefixed “Z”. P
Add the following annexes:
Annex ZA (normative) Normative references to international publications
with their corresponding European publications
Annex ZB (normative) Special national conditions
Annex ZC (informative) A - deviations
Annex ZD (informative) IEC and CENELEC code designations for flexible
cords P
1 Modification to Clause 3 .
N/A
3.3.19 Sound exposure
Replace 3.3.19 of IEC 62368 - 1 with the following definitions: N/A
3.3.19.1
momentary exposure level, MEL
metric for estimating 1 s sound exposure level from
the HD 483 - 1 S2 test signal applied to both channels,
based on EN 50332 - 1: 2013, 4.2.
Note 1 to entry: MEL is measured as A - weighted levels in dB.
Note 2 to entry: See B.3 of EN 50332 - 3:2017 for additional