Page  40   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  O   MEASUREMENT OF CREEPAGE DISTANCES AND  CLEARANCES  
N/A  
  Value of  X   (mm)   ................................ .....................   :  
 
  
P   SAFEGUARDS AGAINST CONDUCTIVE OBJECTS  
N/A  
P.1   General  
  N/A  
P.2   Safeguards against entry or consequences of entry of a foreign object  
N/A  
P.2.1   General   No opening in accessible 
enclosure   N/A  
P.2.2   Safeguards agai nst entry of  a  foreign object     N/A  
  Location and Dimensions (mm)    ............................   :    
  
P.2.3   Safeguards against the consequences of entry of a 
foreign object     N/A  
P.2.3.1   Safeguard requirements     N/A  
  The ES3 and PS3 keep - out volume in Figure P.3 
not applicable to tran sportable equipment      N/A  
  Transportable equipment with metalized plastic 
parts   ................................ ................................ .......   :     N/A  
P.2.3.2   Consequence of entry test   ................................ ....   :     N/A  
P.3   Safeguards against spillage of internal liquids  
N/A  
P.3.1   General   No internal liquids   N/A  
P.3.2   Determination of spilla ge consequences      N/A  
P.3.3   Spillage safeguards     N/A  
P.3.4   Compliance     N/A  
P.4   Metallized coatings and adhesives securing parts  
N/A  
P.4.1   General   No meta l lized coating  and  
adhesive conducted parts   N/A  
P.4.2   Tests     N/A  
  Conditioning, T
C   (°C)   ................................ .............   :    
  
  Du ration (weeks)   ................................ ...................   :    
  
Q   CIRCUITS INTENDED FOR INTERCONNECTION WITH BUILDING WIRING  
P  
Q.1   Limited power sources  
  P  
Q.1.1   Requirements     P  
  a) Inherently limited output     N/A  
  b) Impedance limited output     N/A  
  c) Regulating network limited output     P   
Page 365 of 406

   
 
Page  54   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
Q.1   TABLE: Circuits intended for interconnection with building wiring (LPS)  
N/A  
Output 
Circuit   Condition   U
oc   (V)   Time (s)   I
sc  (A)   S (VA)  
Meas.   Limit   Meas.   Limit  
   
   
   
   
   
   
   
   
Supplementary Information:  
SC=Short circuit, OC=Open circuit  
 
 
T.2, T.3, 
T.4, T.5   TABLE: Steady force test  
N/A  
Part/Location   Material   Thickness 
(mm)   Probe   Force  
(N)   Test 
Duration  
(s)   Observation  
             
Supplementary information:  
 
 
T.6,  T.9   TABLE: Impact test  
P  
Location/part   Material   Thickness 
(mm)   Height 
(mm)   Observation  
Front, Top / Monitor   PC /ABS   Min. 1.5   1 300   No damaged, no hazard  
Front / Keyboard   PC/ABS   Min. 1.5   1 300   No damaged, no hazard  
Supplementary information:  
 
 
T.7     TABL E: Drop test  
N/A  
Location/part   Material   Thickness 
(mm)   Height 
(mm)   Observation  
         
Supplementary information:  
 
  
Page 376 of 406

   
 
Page  65   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 5.7.6.2   Denmark  
To the end of the subclause the following is added:  
The warning  (marking safeguard) for high touch current 
is required if the touch current or the protective current 
exceed the limits of 3,5 mA .     N/A  
B.3.1 and 
B.4   Ireland and United Kingdom  
The following is applicable:  
To protect against excessive currents and short - circuits 
in the primary circuit of  direct plug - in equipment , tests 
according to Annexes B.3.1 and B.4 shall be conducted 
using an external miniature circuit breaker complying 
with EN 60898 - 1, Type B, rated 32A. If the equipment 
does not pass these tests, s uitable protective devices 
shall be included as an integral part of the  direct plug -
in equipment , until the requirements of Annexes B.3.1 
and B.4 are met     N/A  
G.4.2   Denmark  
To the end of the subclause the following is added:  
Supply cords of single phase a ppliances having a rated 
current not exceeding 13 A shall be provided with a plug 
according to DS 60884 - 2 - D1:2011.  
CLASS I EQUIPMENT provided with socket - outlets with earth 
contacts or which are intended to be used in locations where 
protection against ind irect contact is required according to the 
wiring rules shall be provided with a plug in accordance with 
standard sheet DK 2 - 1a or DK 2 - 5a.  
If a single - phase equipment having a RATED CURRENT 
exceeding 13 A or if a poly - phase equipment is provided with 
a su pply cord with a plug, this plug shall be in accordance with 
the standard sheets DK 6 - 1a in DS 60884 - 2 - D1 or EN 60309 -
2.  
Mains socket outlets intended for providing power to 
Class II apparatus with a rated current of 2,5 A shall be 
in accordance DS 60884 - 2 - D1:2011 standard sheet 
DKA 1 - 4a.  
Other current rating socket outlets shall be in 
compliance with Standard Sheet DKA 1 - 3a or DKA 1 -
1c.  
Mains socket - outlets with earth shall be in compliance 
with DS 60884 - 2 - D1:2011 Standard Sheet DK 1 - 3a, DK 
1 - 1c, DK1 - 1d, D K 1 - 5a or DK 1 - 7a  
Justification:  
Heavy Current Regulations, Section 6c     N/A   
Page 396 of 406

   
 
Page  85   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TRF No.  IEC62368_1 C    
 B.3.1 and  
B.4   Ireland and United Kingdom  
 
The following is applicable:  
 
To protect against exce ssive currents and short -
circuits in the primary circuit of  direct plug - in 
equipment , tests according to Annexes B.3.1 and 
B.4 shall be conducted using an external miniature 
circuit breaker complying with EN 60898 - 1, Type B, 
rated 32A. If the equipment doe s not pass these 
tests, suitable protective devices shall be included 
as an integral part of the  direct plug - in equipment , 
until the requirements of Annexes B.3.1 and B.4 are 
met     N/A  
G.4.2   Denmark  
 
To the end of the subclause the following is added:  
 
Sup ply cords of single phase appliances having a 
rated current not exceeding 13 A shall be provided 
with a plug according to DS 60884 - 2 - D1:2011.  
 
CLASS I EQUIPMENT provided with socket - outlets 
with earth contacts or which are intended to be used 
in locations  where protection against indirect contact 
is required according to the wiring rules shall be 
provided with a plug in accordance with standard 
sheet DK 2 - 1a or DK 2 - 5a.  
 
If a single - phase equipment having a RATED 
CURRENT exceeding 13 A or if a polyphase  
equ ipment is provided with a supply cord with a 
plug, this plug shall be in accordance with the 
standard sheets DK 6 - 1a in DS 60884 - 2 - D1 or EN 
60309 - 2.  
 
Mains socket outlets intended for providing power to 
Class II apparatus with a rated current of 2,5 A shal l 
be in accordance DS 60884 - 2 - D1:2011 standard 
sheet DKA 1 - 4a.  
 
Other current rating socket outlets shall be in 
compliance with Standard Sheet DKA 1 - 3a  
or DKA 1 - 1c.  
 
Mains socket - outlets with earth shall be in 
compliance with DS 60884 - 2 - D1:2011  
Standard Sh eet DK 1 - 3a, DK 1 - 1c, DK1 - 1d, DK 1 - 5a 
or DK 1 - 7a  
 
Justification:  
Heavy Current Regulations, Section 6c     N/A