wiring Seat Ibiza 2020 Directive 2014/53/EU Bluetooth
[x] Cancel search | Manufacturer: SEAT, Model Year: 2020, Model line: Ibiza, Model: Seat Ibiza 2020Pages: 406, PDF Size: 9.22 MB
Page 351 of 406

Page 40 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
O MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES
N/A
Value of X (mm) ................................ ..................... :
P SAFEGUARDS AGAINST CONDUCTIVE OBJECTS
N/A
P.1 General
N/A
P.2 Safeguards against entry or consequences of entry of a foreign object
N/A
P.2.1 General No opening in accessible
enclosure N/A
P.2.2 Safeguards agai nst entry of a foreign object N/A
Location and Dimensions (mm) ............................ :
P.2.3 Safeguards against the consequences of entry of a
foreign object N/A
P.2.3.1 Safeguard requirements N/A
The ES3 and PS3 keep - out volume in Figure P.3
not applicable to tran sportable equipment N/A
Transportable equipment with metalized plastic
parts ................................ ................................ ....... : N/A
P.2.3.2 Consequence of entry test ................................ .... : N/A
P.3 Safeguards against spillage of internal liquids
N/A
P.3.1 General No internal liquids N/A
P.3.2 Determination of spilla ge consequences N/A
P.3.3 Spillage safeguards N/A
P.3.4 Compliance N/A
P.4 Metallized coatings and adhesives securing parts
N/A
P.4.1 General No meta l lized coating and
adhesive conducted parts N/A
P.4.2 Tests N/A
Conditioning, T
C (°C) ................................ ............. :
Du ration (weeks) ................................ ................... :
Q CIRCUITS INTENDED FOR INTERCONNECTION WITH BUILDING WIRING
P
Q.1 Limited power sources
P
Q.1.1 Requirements P
a) Inherently limited output N/A
b) Impedance limited output N/A
c) Regulating network limited output P
Page 365 of 406

Page 54 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS)
N/A
Output
Circuit Condition U
oc (V) Time (s) I
sc (A) S (VA)
Meas. Limit Meas. Limit
Supplementary Information:
SC=Short circuit, OC=Open circuit
T.2, T.3,
T.4, T.5 TABLE: Steady force test
N/A
Part/Location Material Thickness
(mm) Probe Force
(N) Test
Duration
(s) Observation
Supplementary information:
T.6, T.9 TABLE: Impact test
P
Location/part Material Thickness
(mm) Height
(mm) Observation
Front, Top / Monitor PC /ABS Min. 1.5 1 300 No damaged, no hazard
Front / Keyboard PC/ABS Min. 1.5 1 300 No damaged, no hazard
Supplementary information:
T.7 TABL E: Drop test
N/A
Location/part Material Thickness
(mm) Height
(mm) Observation
Supplementary information:
Page 376 of 406

Page 65 of 88 Report No. : 60404490 001
IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.7.6.2 Denmark
To the end of the subclause the following is added:
The warning (marking safeguard) for high touch current
is required if the touch current or the protective current
exceed the limits of 3,5 mA . N/A
B.3.1 and
B.4 Ireland and United Kingdom
The following is applicable:
To protect against excessive currents and short - circuits
in the primary circuit of direct plug - in equipment , tests
according to Annexes B.3.1 and B.4 shall be conducted
using an external miniature circuit breaker complying
with EN 60898 - 1, Type B, rated 32A. If the equipment
does not pass these tests, s uitable protective devices
shall be included as an integral part of the direct plug -
in equipment , until the requirements of Annexes B.3.1
and B.4 are met N/A
G.4.2 Denmark
To the end of the subclause the following is added:
Supply cords of single phase a ppliances having a rated
current not exceeding 13 A shall be provided with a plug
according to DS 60884 - 2 - D1:2011.
CLASS I EQUIPMENT provided with socket - outlets with earth
contacts or which are intended to be used in locations where
protection against ind irect contact is required according to the
wiring rules shall be provided with a plug in accordance with
standard sheet DK 2 - 1a or DK 2 - 5a.
If a single - phase equipment having a RATED CURRENT
exceeding 13 A or if a poly - phase equipment is provided with
a su pply cord with a plug, this plug shall be in accordance with
the standard sheets DK 6 - 1a in DS 60884 - 2 - D1 or EN 60309 -
2.
Mains socket outlets intended for providing power to
Class II apparatus with a rated current of 2,5 A shall be
in accordance DS 60884 - 2 - D1:2011 standard sheet
DKA 1 - 4a.
Other current rating socket outlets shall be in
compliance with Standard Sheet DKA 1 - 3a or DKA 1 -
1c.
Mains socket - outlets with earth shall be in compliance
with DS 60884 - 2 - D1:2011 Standard Sheet DK 1 - 3a, DK
1 - 1c, DK1 - 1d, D K 1 - 5a or DK 1 - 7a
Justification:
Heavy Current Regulations, Section 6c N/A
Page 396 of 406

Page 85 of 88 Report No. : 60404490 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC62368_1 C
B.3.1 and
B.4 Ireland and United Kingdom
The following is applicable:
To protect against exce ssive currents and short -
circuits in the primary circuit of direct plug - in
equipment , tests according to Annexes B.3.1 and
B.4 shall be conducted using an external miniature
circuit breaker complying with EN 60898 - 1, Type B,
rated 32A. If the equipment doe s not pass these
tests, suitable protective devices shall be included
as an integral part of the direct plug - in equipment ,
until the requirements of Annexes B.3.1 and B.4 are
met N/A
G.4.2 Denmark
To the end of the subclause the following is added:
Sup ply cords of single phase appliances having a
rated current not exceeding 13 A shall be provided
with a plug according to DS 60884 - 2 - D1:2011.
CLASS I EQUIPMENT provided with socket - outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2 - 1a or DK 2 - 5a.
If a single - phase equipment having a RATED
CURRENT exceeding 13 A or if a polyphase
equ ipment is provided with a supply cord with a
plug, this plug shall be in accordance with the
standard sheets DK 6 - 1a in DS 60884 - 2 - D1 or EN
60309 - 2.
Mains socket outlets intended for providing power to
Class II apparatus with a rated current of 2,5 A shal l
be in accordance DS 60884 - 2 - D1:2011 standard
sheet DKA 1 - 4a.
Other current rating socket outlets shall be in
compliance with Standard Sheet DKA 1 - 3a
or DKA 1 - 1c.
Mains socket - outlets with earth shall be in
compliance with DS 60884 - 2 - D1:2011
Standard Sh eet DK 1 - 3a, DK 1 - 1c, DK1 - 1d, DK 1 - 5a
or DK 1 - 7a
Justification:
Heavy Current Regulations, Section 6c N/A