Page 23 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
6.4.3 Redu ction of the likelihood of ignition under single
fault conditions in PS2 and PS3 circuits N/A
6.4.3.1 Supplementary safeguards N/A
6.4.3.2 Single Fault Conditions ................................ .......... : N/A
Special conditions for temperature limited by fuse N/A
6.4.4 Control of fire spread in PS1 circuits P
6.4.5 Control of fire spread in PS2 circuits P
6.4.5.2 Supplementary safeguards For conductor and devices are
mounted on printed board
made of Min. V - 1.
Other components in PS2 are
mounted on printed board
made of Min. V - 1 and PVC
wire used .
Not ignite during single fault
condition . P
6.4.6 Control of fire spread in PS3 circuits Provided Metallic enclosure P
6.4.7 Separation of combustible materials from a PIS P
6.4.7.2 Separation by distance N/A
6.4.7.3 Separation by a f ire barrier P
6.4.8 Fire enclosures and fire barriers P
6.4.8.2 Fire enclosure and fire barrier material properties P
6.4.8.2.1 Requirements for a fire barrier V - 0 class material or metal,
Printed board made of V - 0 P
6.4.8.2.2 Requirem ents for a fire enclosure Metallic enclosure provided P
6.4.8.3 Constructional requirements for a fire enclosure
and a fire barrier P
6.4.8.3.1 Fire enclosure and fire barrier openings P
6.4.8.3.2 Fire barrier dimensions P
6.4.8.3.3 Top openings and properties E quipment for building - in ,
e valuation shall be considered
in the end product N/A
Openings dimensions (mm) ................................ ... : N/A
6.4.8.3.4 Bottom openings and properties E quipment for building - in ,
e valuation shall be considered
in the end product N/A
Open ings dimensions (mm) ................................ ... : N/A
Flammability tests for the bottom of a fire enclosure N/A
Page 37 of 406

Page 32 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
F.3.3.6 Rated current or rated power ................................ : See copy of marking plate P
F.3.3.7 Equipment with multiple supply connections N/A
F.3.4 Voltage setting device N/A
F.3.5 Terminals and operating devices N/A
F.3.5.1 Mains appliance outlet an d socket - outlet markings
................................ ................................ ............... : No such component N/A
F.3.5.2 Switch position identification marking .................... : No such component N/A
F.3.5.3 Replacement fuse identification and rating
markings ................................ ................................ : No replaceable fuse N/A
Instructional safeguards for neutral fuse ............... : N o such component N/A
F.3.5.4 Replacement battery identification marking .......... : No replaceable battery N/A
F.3.5.5 Neutral conductor terminal N/A
F.3.5.6 Terminal marking location N/A
F.3.6 Equipment markings related to equipment
classification N/A
F.3.6 .1 Class I equipment N/A
F.3.6.1.1 Protective earthing conductor terminal .................. : N/A
F.3.6.1.2 Protective bonding conductor terminals ............... : N/A
F.3.6.2 Equipment class marking ................................ ...... : N/A
F.3.6.3 Functional earthing terminal marking .................... : N/A
F.3.7 Equipment IP ra ting marking ................................ . : N/A
F.3.8 External power supply output marking .................. : N/A
F.3.9 Durability, legibility and permanence of marking P
F.3.10 Test for permanence of markings P
F.4 Instructions
N/A
a) Information prior to installation and initial use It sha ll be evaluated in the
end - equipment N/A
b) Equipment for use in locations where children not
likely to be present N/A
c) Instructions for installation and interconnection N/A
d) Equipment intended for use only in restricted
access area N/A
e) Equipment intended to be fastened in place N/A
f) Instructions for audio equipment terminals N/A
g) Protective earthing used as a safeguard N/A
Page 54 of 406

Page 49 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.5.2.2 TABLE: Stored discharge on capacitors
N/A
Location Supply voltage (V) Operating and fault
condition 1)
Switch
position Measured
voltage
(Vpk) ES Class
Supplementary information:
X - capacitors installed for testin g:
bleeding resistor rating:
ICX:
1) Normal operating condition (e.g., normal operation, or open fuse), SC= short circuit, OC= open circuit
5.6.6 TABLE: Resistance of protective conductors and terminations
N/A
Loca tion Test current
(A) Duration
(min) Voltage drop
(V) Resistance
( Ω )
Supplementary information:
5.7.4 TABLE: Unearthed accessible parts
N/A
Location Operating and
fault conditions Supply
Voltage (V) Parameters ES
class
Voltage
(V
rms or V
pk ) Current
(A
rms or A
pk ) Freq.
(Hz)
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit
5.7.5 TABLE: Earthed accessible conductive part
N/A
Supply voltage (V) ........................... :
Phase(s) ................................ ......... : [] Single Phase; [ ] Three Pha se : [ ] Delta [ ] W ye
Power Distribution System ............. : TN TT IT
Location Fault Condition No in IEC
60990 clause 6.2.2 Touch current
(mA) Comment
Supplementary Information:
Page 58 of 406

Page 53 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
16. Power key knob body 25.5 29.5 - 60
17. Enclosure near media button 28.6 32.6 - 77
18. Frame body (Not accessible) 34.4 - 98.4 -
19. Metal enclosure body (Not accessible) 40.4 - 104.4 -
Ambient temperature See
above See
above See
above -
Temperature T of winding: t
1 (°C)
R
1 ( ) t
2 (°C)
R
2 ( ) T ( C) Allowed
T
max ( C) Insulation
class
Supplementary information:
Note 1. The temperatures for accessible parts are adjusted to reflect a value of 25 °C .
Note 2. Maximum operating Temperature pe rmitted by the Manufacturer(Tma) is 85 C .
B.2.5 TABLE: Input test
P
U (V) Hz I (A) I rated (A) P (W) P rated (W) Fuse No I fuse (A) Condition/status
10.2 -
2.31 -
23.56 - - -
Max. normal
load condition.
12.0 -
2.20 3.5
26.40 - - -
Max. normal
load condition.
14.4 -
2.16 -
31.10 - - -
Max. normal
lo ad condition.
Supplementary information:
Max. normal load condition : The equipment is operated in such a way as to deliver one - eighth of the NON -
CLIPPED OUTPUT POWER to the RATED LOAD IMPEDANCE ( 4Ω ) using the standard signal described
in Annex E and Max. brightness for LCD module.
Page 59 of 406

Page 54 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
B.3, B.4 TABLE: Abnormal operating and fault condition tests
P
Ambient temperature T
amb ( C) ................................ ..................... : 2 1 - 2 3
Power source for EUT: Manufacturer, model/type, outputrating .. : -
Component No. Condition Supply
voltage
(V) Test
tim e Fuse no. Fuse
current
(A) Observation
Ventilation
openings Block ed 14.4 2 h - - FI : 2.16 A, NO,
CT (Monitor body : 3 8.0 C,
Power key knob body : 2 6.1
C, Enclosure near media
button : 29.4 C, Ambient :
2 1.2 C, NCD, NH
Speaker output Max. non -
clipp ed output 14.4 2 h - - FI : Max. 3.43 A, NO,
CT ( Amp IC body (IC163) :
80.4 C , Monitor body : 3 8.0
C, Power key knob body :
26.3 C, Enclosure near
media button : 29.5 C,
Ambient : 2 1.5 C, NCD, NH
Speaker output SC 14.4 1 h - - FI : 0.5 - 1.5 5 A , IP , NCD,
NH
IC101(3,8) SC 14.4 1 h - - FI : 0.5 A , CD(IC101) , NH
IC902(1,6) SC 14.4 1 h - - FI : 0.5 A , CD(IC902) , NH
Supplementary information:
Abbreviation:
FI – Final Input Current; IP – Internal protection operated; NO – Normal Operated;
CD – Componen t Damaged (list damaged components); NCD – No Component Damaged;
NH – No Hazard ; CT – Constant temperatures were obtained (list components: temperature;);
NB – No indication of dielectric breakdown; YB – Dielectric breakdown (indicate time and location);
NC – Cheesecloth remained intact; YC – Cheesecloth charred or flamed;
Page 63 of 406

Page 58 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4.1.2 TABLE: Critical components information
P
Object / part No. Manufacturer/
trademark Type / model Technical data S tandard Mark(s) of
conformity 1)
Plastic
Enclosure LG CHEM LTD LUPOY GN -
5007F(#) V - 0 UL 94 UL ( E67171 )
Alternate Interchangeable Interchangeable Min. HB UL 94 UL
- Description: Interchangeability based on specified ratings
Metal Enclosure Interchangeabl e Interchangeable AL or EGI(SECC)
or GI(SGCC) or
NI or ALDC or
MG or SUS or
STS or NSP or
STEEL, Min. 0.4
thickness IEC 62368 - 1 Tested in
equipment
- Description: Interchangeability based on specified ratings and dimensions
PCB ZHEJIANG
HUABANG
ELE CTRONICS
CO LTD H - 01 V - 0 UL 796 UL ( E251053 )
Alternate HYUN WOO
INDUSTRIAL
CO LTD 3 V - 0 UL 796 UL (E131308)
Alternate Interchangeable Interchangeable Min. V - 1 UL 796 UL
- Description: Interchangeability based on specified ratings
LCD Panel LG Display Co.,
Ltd. LA065WV1 6.5 inch ,
( 800 x 480 ) IEC 62368 - 1 Tested in
equipment
Alternate LG Display
(Paju) Co., Ltd. LA065WV3 6.5 inch ,
( 800 x 480 ) IEC 60065 T Ü V - Rh
(JPTUV -
080511)
Alternate Giantplus
Technology Co.,
LTD. GPM1696A0 6.5 inch ,
( 800 x 480 ) IEC 60065 SGS F imko
(FI - 37636)
Mains connector
material KURARAY CO
LTD GN2330(#) V - 0 UL 94 UL (E90350)
Alternate Interchangeable Interchangeable Min. V - 1 UL 94 UL
- Description: Inte rchangeability based on specified ratings
Fuse ST VN5E010MHTR -
E 13A Switch off ISO/TS
16949:2009 9136.STM2
Supplementary information:
1)
Provided evidence ensures the agreed level of compliance. See OD - 2039.
Page 65 of 406

Page 60 of 90 Report No. : 60404487 001
IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
For special national conditions, see Annex ZB.
1 Add the following note:
NOTE Z1 The use of certain substances in electrical and electronic
equipment is restricted within the EU: see Directive 2011/65/EU. P
4.Z1 Add the following new subclause after 4.9:
To protect against excessive current, short - circuits and
earth faults in circuits connected to an a.c. mains ,
protective devices shall be included either as integ ral
parts of the equipment or as parts of the building
installation, subject to the following, a), b) and c):
a) except as detailed in b) and c), protective devices
necessary to comply with the requirements of B.3.1 and
B.4 shall be included as parts of th e equipment;
b) for components in series with the mains input to the
equipment such as the supply cord, appliance coupler,
r.f.i. filter and switch, short - circuit and earth fault
protection may be provided by protective devices in the
building installation ;
c) it is permitted for pluggable equipment type B or
permanently connected equipment , to rely on
dedicated overcurrent and short - circuit protection in the
building installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fu lly
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so state,
except that for pluggable equipment type A the
building installation shall be regarded as provid ing
protection in accordance with the rating of the wall
socket outlet. N/A
5.4.2.3.2.4 Add the following to the end of this subclause:
The requirement for interconnection with external
circuit is in addition given in EN 50491 - 3:2009. N/A
10.2.1 Add th e following to c)
and d)
in table 39:
For additional requirements, see 10.5.1. N/A
Page 70 of 406

Page 65 of 90 Report No. : 60404487 001
IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.5.6 Finland, Norway and Sweden
To the end of the subclause the following is added:
Resistors used as basic safeguard or bridging basic
insulation in class I pluggable equipment type A
shall comply w ith G.10.1 and the test of G.10.2. N/A
5.6.1 Denmark
Add to the end of the subclause
Due to many existing installations where the socket -
outlets can be protected with fuses with higher rating
than the rating of the socket - outlets the protection for
plugg able equipment type A shall be an integral part of
the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse. N/A
5.6.4.2.1 Ireland and United Kingdom
After the indent for pluggable equipment type A , the
foll owing is added:
– the protective current rating is taken to be 13 A, this
being the largest rating of fuse used in the mains plug. N/A
5.6.5.1 To the second paragraph the following is added:
The range of conductor sizes of flexible cords to be
accepted b y terminals for equipment with a rated
current over 10 A and up to and including 13 A is:
1,25 mm 2
to 1,5 mm 2
in cross - sectional area. N/A
5.7.5 Denmark
To the end of the subclause the following is added:
The installation instruction shall be affixed to the
equipment if the protective conductor current
exceeds the limits of 3,5 mA a.c. or 10 mA d.c. N/A
Page 85 of 406

Page 80 of 90 Report No. : 60404487 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5
Modification to 4.Z1
N /A
4.Z1 Add the following new subclause after 4.9:
To protect against excessive current, short - circuits
and earth faults in circuits connected to an a.c.
mains , protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a), b)
and c):
a) except as detailed in b) and c), protective devices
necessary to comply with the requirements of B.3.1
and B.4 shall be included as parts of the equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short - circuit and earth
fault protection may be provided by protective
devices in the building installation;
c) it is permitted for pluggable equipm ent type B or
permanently connected equipment , to rely on
dedicated overcurrent and short - circuit protection in
the building installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fully
specified in the installation instruc tions.
If reliance is placed on protection in the building
installation, the installation instructions shall so state,
except that for pluggable equipment type A the
building installation shall be regarded as providing
protection in accordance with the ra ting of the wall
socket outlet. N/A
6
Modification to 5.4.2.3.2.4
N/A
5.4.2.3.2.4 Add the following to the end of this subclause:
The requirement for interconnection with external
circuit is in addition given in EN 50491 - 3:2009. N/A
7
Modification to 10.2.1
N/A
10.2.1
Add the following to c)
and d)
in table 39:
For additional requirements, see 10.5.1. N/A
Page 89 of 406

Page 84 of 90 Report No. : 60404487 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC62368_1 C
A capacitor classified Y3 according to EN 60384 -
14:2005, may bridge this insulation under
the following conditions:
• the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
60384 - 14, which in addition to the Y3 tes ting, is
tested with an impulse test of 2,5 kV defined in
5.4.11;
• the additional testing shall be performed on all the
test specimens as described in EN 60384 - 14;
the impulse test of 2,5 kV is to be performed before
the endurance test in EN 60384 - 14, in the sequence
of tests as described in EN 60384 - 14.
5.5.2.1 Norway
After the 3rd paragraph the following is added:
Due to the IT power system used, capacitors are
required to be rated for the applicable line - to - line
voltage (230 V). N/A
5.5.6 Finland, Norway and Sweden
To the end of the subclause the following is added:
Resistors used as basic safeguard or bridging
basic insulation in class I pluggable equipment
type A shall comply with G.10.1 and the test of
G.10.2. N/A
5.6.1 Denmark
Add to the end of the subclause
Due to many existing installations where the socket -
outlets can be protected with fuses
with higher rating than the rating of the socket -
outlets the protection for pluggable
equipment type A shall be an integral part of the
equi pment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse. N/A
5.6.4.2.1 Ireland and United Kingdom
After the indent for pluggable equipment type A ,
the following is added:
– the protective current rating is taken t o be 13 A,
this being the largest rating of fuse used in the
mains plug. N/A