relay Seat Ibiza 2020 Directive 2014/53/EU Bluetooth
[x] Cancel search | Manufacturer: SEAT, Model Year: 2020, Model line: Ibiza, Model: Seat Ibiza 2020Pages: 406, PDF Size: 9.22 MB
Page 21 of 406

Page 16 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4.5 Explosion
N/A
4.5.1 General N/A
4.5.2 No explosion during normal/abnormal operating
condition N/A
No harm by explosion during single fault conditions N/A
4.6 Fixing of conductors
N/A
Fix conductors not to defeat a safeguard N/A
Compliance is checked by test .............................. : N/A
4.7 Equipment for direct insertion into mains socket – outlets
N/A
4.7.2 Mains plug part complies with relevant standard .. : No direct insertion into m ains
socket - outlets N/A
4.7.3 Torque (Nm) ................................ .......................... : N/A
4.8 Equipment containing coin/button cell batteries
N/A
4.8.1 General No lithium coin/button
batteries are used N/A
4.8.2 Instructional safeguard ................................ .......... : N/A
4.8.3 Battery compartment door/cover construction N/A
Open torque test N/A
4.8.4.2 Stress relief test N/A
4.8.4.3 Battery replacement test N/A
4.8.4.4 Drop test N/A
4.8.4.5 Impact test N/A
4.8.4.6 Crush test N/A
4.8.5 Compliance N/A
30N force test with test probe N/A
20N force test w ith test hook N/A
4.9 Likelihood of fire or shock due to entry of conductive object
N/A
4.10 Component requirements
N/A
4.10.1 Disconnect Device N/A
4.10.2 Switches and relays No such component is used N/A
5 ELECTRICALLY - CAUSED INJURY
P
5.2 Classi fication and limits of electrical energy sources
P
5.2.2 ES1, ES2 and ES3 limits ES1 P
Page 25 of 406

Page 20 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.4.11.1 Exceptions to separation between external circuits
and earth N/A
5.4.11.2 Requirements N/A
SP Ds bridge separation between external circuit
and earth N/A
Rated operating voltage U
op (V) ............................. :
Nominal voltage U
peak (V) ................................ ....... :
Max increase due to variation U
sp ........................ :
Max increase due to ageing U
sa ......................... :
5.4.11.3 Test method and compliance ................................ : N/A
5.4.12 Insulating liquid N/A
5.4.12.1 General requirements N/A
5.4.12.2 Electric strength of an insulating liquid .................. : N/A
5.4.12.3 Compatibility of an insulating liquid ....................... : N/A
5.4.12.4 Container for insulating liquid ................................ : N/A
5.5 Components as saf eguards
N/A
5.5.1 General N/A
5.5.2 Capacitors and RC units No such component N/A
5.5.2.1 General requirement N/A
5.5.2.2 Safeguards against capacitor discharge after
disconnection of a connector ................................ . : N/A
5.5.3 Transformers No transformers N/A
5.5.4 Optocouplers No o ptocouplers N/A
5.5.5 Relays No Relays N/A
5.5.6 Resistors No Resistors N/A
5.5.7 SPDs No SPDs N/A
5.5.8 Insulation between the mains and an external
circuit consisting of a coaxial cable ....................... : N/A
5.5.9 Safeguards for socket - outlets in outdoor equipment N/A
RCD rated residual operating current (mA) ........... :
5.6 Protective conductor
N/A
5.6.2 Requirement for protective conductors N/A
5.6 Protective conductor
N/A
5.6.2 Requirement for protective conductors N/A
Page 38 of 406

Page 33 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
h) Protective conductor current exceeding ES2 limits N/A
i) Graphic symbols used on equipment N/A
j) Permanently connected equipment not provided
with all - pole mains switch N/A
k) Replaceable components or modules providing
safeguard function N/A
l) Equipment containing insulating liquid N/A
m ) Installation instructions for outdoor equipmen t N/A
F.5
Instructional safeguards N/A
G COMPONENTS
N/A
G.1 Switches
N/A
G.1.1 General No such switches are used as
disconnect devices N/A
G.1.2 Ratings, endurance, spacing, maximum load N/A
G.1.3 Test method and compliance N/A
G.2 Relays
N/A
G .2.1 Requirements No such relays are used as
disconnect devices N/A
G.2.2 Overload test N/A
G.2.3 Relay controlling connectors supplying power to
other equipment N/A
G.2.4 Test method and compliance N/A
G.3 Protective devices
N/A
G.3.1 Thermal cut - offs No thermal cut - offs N/A
Thermal cut - outs separately approved according to
IEC 60730 with conditions indicated in a) & b) N/A
Thermal cut - outs tested as part of the equipment as
indicated in c) N/A
G.3.1.2 Test method and compliance N/A
G.3. 2 Thermal links No thermal links N/A
G.3.2.1 a) Thermal links tested separately according to IEC
60691 with specifics N/A
b) Thermal links tested as part of the equipment N/A
G.3.2.2 Test method and compliance N/A
G.3.3 PTC thermistors No PTC ther mistors N/A
G.3.4 Overcurrent protection devices N/A
Page 125 of 406

Page 15 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4.5 Explosion
N/A
4.5.1 General N/A
4.5.2 No explosion during normal/abnormal operating
condition N/A
No harm by explosion during single fault conditions N/A
4.6 Fixing of conductors
N/A
Fix conductors not to defeat a safeguard N/A
Compliance is checked by test .............................. : N/A
4.7 Equipment for direct insertion into mains socket – outlets
N/A
4.7.2 Mains plug part complies with relevant standard .. : No direct insertion into mains
socket - outlets N/A
4.7.3 Torque (Nm) ................................ .......................... : N/A
4.8 Equipment containing coin/button cell batteries
N/A
4.8.1 General No lithium coin/button
batteries are used N/A
4.8.2 Instructional safeguard ................................ .......... : N/A
4.8.3 Battery compartment door/cover construction N/A
Open torque test N/A
4.8.4.2 Stress reli ef test N/A
4.8.4.3 Battery replacement test N/A
4.8.4.4 Drop test N/A
4.8.4.5 Impact test N/A
4.8.4.6 Crush test N/A
4.8.5 Compliance N/A
30N force test with test probe N/A
20N force test with test hook N/A
4.9 Likelihood of fire or shoc k due to entry of conductive object
N/A
4.10 Component requirements
N/A
4.10.1 Disconnect Device N/A
4.10.2 Switches and relays No such component is used N/A
5 ELECTRICALLY - CAUSED INJURY
P
5.2 Classification and limits of electrical energy sources
P
5.2.2 ES1, ES2 and ES3 limits ES1 P
Page 129 of 406

Page 19 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.4.11.1 Exceptions to separation between external circuits
and earth N/A
5.4.11.2 Requirements N/A
SPDs bridge separation between external circuit
and earth N/A
Rated operating voltage U
op (V) ............................. :
Nominal voltage U
peak (V) ................................ ....... :
Max increase due to variation U
sp ........................ :
Max increase due to ageing U
sa ......................... :
5.4.11.3 Test method and compliance ................................ : N/A
5.4.12 Insulating liquid N/A
5.4.12.1 Gener al requirements N/A
5.4.12.2 Electric strength of an insulating liquid .................. : N/A
5.4.12.3 Compatibility of an insulating liquid ....................... : N/A
5.4.12.4 Container for insulating liquid ................................ : N/A
5.5 Components as safeguards
N/A
5.5.1 General N/A
5.5.2 Capacitors and RC units No such component N/A
5.5.2.1 General requirement N/A
5.5.2.2 Safeguards against capacitor discharge after
disconnection of a connector ................................ . : N/A
5.5.3 Transformers No transformers N/A
5.5.4 Optocouplers No o ptocouplers N/A
5.5.5 Relays No Relays N/A
5.5.6 Resistors No Resistors N/A
5.5.7 SPDs No SPDs N/A
5.5.8 Insulation between the mains and an external
circuit consisting of a coaxial cable ....................... : N/A
5.5.9 Safeguards for socket - outlets in outdoor equipment N/A
RCD rated residual operat ing current (mA) ........... :
5.6 Protective conductor
N/A
5.6.2 Requirement for protective conductors N/A
5.6 Protective conductor
N/A
5.6.2 Requirement for protective conductors N/A
Page 142 of 406

Page 32 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
h) Protective conductor current exceeding ES2 limits N/A
i) Graphic symbols used on equipment N/A
j) Permanently connected equipment not provid ed
with all - pole mains switch N/A
k) Replaceable components or modules providing
safeguard function N/A
l) Equipment containing insulating liquid N/A
m ) Installation instructions for outdoor equipment N/A
F.5
Instructional safeguards N/A
G COMP ONENTS
N/A
G.1 Switches
N/A
G.1.1 General No such switches are used as
disconnect devices N/A
G.1.2 Ratings, endurance, spacing, maximum load N/A
G.1.3 Test method and compliance N/A
G.2 Relays
N/A
G.2.1 Requirements No such relays are used as
dis connect devices N/A
G.2.2 Overload test N/A
G.2.3 Relay controlling connectors supplying power to
other equipment N/A
G.2.4 Test method and compliance N/A
G.3 Protective devices
N/A
G.3.1 Thermal cut - offs No thermal cut - offs N/A
Thermal cut - outs separately approved according to
IEC 60730 with conditions indicated in a) & b) N/A
Thermal cut - outs tested as part of the equipment as
indicated in c) N/A
G.3.1.2 Test method and compliance N/A
G.3.2 Thermal links No thermal links N/A
G.3.2.1 a) Thermal links tested separately according to IEC
60691 with specifics N/A
b) Thermal links tested as part of the equipment N/A
G.3.2.2 Test method and compliance N/A
G.3.3 PTC thermistors No PTC thermistors N/A
G.3.4 Overcurrent protection device s N/A
Page 227 of 406

Page 14 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4.5 Explosion
N /A
4.5.1 General N/A
4.5.2 No explosion during normal/abnormal operating
condition N/A
No harm by explosion during single fault conditions N/A
4.6 Fixing of conductors
N/A
Fix conductors not to defeat a safeguard N/A
Compliance is checked by test .............................. : N/A
4.7 Equipment for direct insertion into mains socket – outlets
N/A
4.7.2 Mains plug part complies with relevant standard .. : No direct insertion into mains
socket - outlets N/A
4.7.3 Torque (Nm) ................................ .......................... : N/A
4.8 Equipment containing coin/button cell ba tteries
N/A
4.8.1 General No lithium coin/button
batteries are used N/A
4.8.2 Instructional safeguard ................................ .......... : N/A
4.8.3 Battery compartment door/cover construction N/A
Open torque test N/A
4.8.4.2 Stress relief test N/A
4.8.4.3 Battery replacement tes t N/A
4.8.4.4 Drop test N/A
4.8.4.5 Impact test N/A
4.8.4.6 Crush test N/A
4.8.5 Compliance N/A
30N force test with test probe N/A
20N force test with test hook N/A
4.9 Likelihood of fire or shock due to entry of conductive object
N/A
4.10 Component requirements
N/A
4.10.1 Disconnect Device N/A
4.10.2 Switches and relays No such component is used N/A
5 ELECTRICALLY - CAUSED INJURY
P
5.2 Classification and limits of electrical energy sources
P
5.2.2 ES1, ES2 and ES3 limits ES1 P
Page 231 of 406

Page 18 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.4.11.1 Exceptions to separation between external circuits
and earth N/A
5.4.11.2 Requirements N/A
SPDs bridge separation between external circuit
and earth N/A
Rated operating voltage U
op (V) ............................. :
Nominal voltage U
peak (V) ................................ ....... :
Max increase due to variation U
sp ........................ :
Max increase due to ageing U
sa ......................... :
5.4.11.3 Test method and compliance ................................ : N/A
5.4.12 Insulating liquid N/A
5.4.12.1 General requirements N/A
5.4.12.2 Electric stren gth of an insulating liquid .................. : N/A
5.4.12.3 Compatibility of an insulating liquid ....................... : N/A
5.4.12.4 Container for insulating liquid ................................ : N/A
5.5 Components as safeguards
N/A
5.5.1 General N/A
5.5.2 Capacitors and RC units No such component N/A
5.5.2.1 G eneral requirement N/A
5.5.2.2 Safeguards against capacitor discharge after
disconnection of a connector ................................ . : N/A
5.5.3 Transformers No transformers N/A
5.5.4 Optocouplers No o ptocouplers N/A
5.5.5 Relays No Relays N/A
5.5.6 Resistors No Resistors N/A
5.5.7 SPDs No SPDs N/A
5.5.8 Insulation between the mains and an external
circuit consisting of a coaxial cable ....................... : N/A
5.5.9 Safeguards for socket - outlets in outdoor equipment N/A
RCD rated residual operating current (mA) ........... :
5.6 Protective conduct or
N/A
5.6.2 Requirement for protective conductors N/A
5.6 Protective conductor
N/A
5.6.2 Requirement for protective conductors N/A
Page 244 of 406

Page 31 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
h) Protective conductor current exceeding ES2 limits N/A
i) Graphic symbols used on equipment N/A
j) Permanently connected equipment not provided
with al l - pole mains switch N/A
k) Replaceable components or modules providing
safeguard function N/A
l) Equipment containing insulating liquid N/A
m ) Installation instructions for outdoor equipment N/A
F.5
Instructional safeguards N/A
G COMPONENTS
N/A
G.1 Switches
N/A
G.1.1 General No such switches are used as
disconnect devices N/A
G.1.2 Ratings, endurance, spacing, maximum load N/A
G.1.3 Test method and compliance N/A
G.2 Relays
N/A
G.2.1 Requirements No such relays are used as
disconnect de vices N/A
G.2.2 Overload test N/A
G.2.3 Relay controlling connectors supplying power to
other equipment N/A
G.2.4 Test method and compliance N/A
G.3 Protective devices
N/A
G.3.1 Thermal cut - offs No thermal cut - offs N/A
Thermal cut - outs separatel y approved according to
IEC 60730 with conditions indicated in a) & b) N/A
Thermal cut - outs tested as part of the equipment as
indicated in c) N/A
G.3.1.2 Test method and compliance N/A
G.3.2 Thermal links No thermal links N/A
G.3.2.1 a) Thermal l inks tested separately according to IEC
60691 with specifics N/A
b) Thermal links tested as part of the equipment N/A
G.3.2.2 Test method and compliance N/A
G.3.3 PTC thermistors No PTC thermistors N/A
G.3.4 Overcurrent protection devices N/A
Page 325 of 406

Page 14 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4.5 Explosion
N /A
4.5.1 General N/A
4.5.2 No explosion during normal/abnormal operating
condition N/A
No harm by explosion during single fault conditions N/A
4.6 Fixing of conductors
N/A
Fix conductors not to defeat a safeguard N/A
Compliance is checked by test .............................. : N/A
4.7 Equipment for direct insertion into mains socket – outlets
N/A
4.7.2 Mains plug part complies with relevant standard .. : No direct insertion into mains
socket - outlets N/A
4.7.3 Torque (Nm) ................................ .......................... : N/A
4.8 Equipment containing coin/button cell ba tteries
N/A
4.8.1 General No lithium coin/button
batteries are used N/A
4.8.2 Instructional safeguard ................................ .......... : N/A
4.8.3 Battery compartment door/cover construction N/A
Open torque test N/A
4.8.4.2 Stress relief test N/A
4.8.4.3 Battery replacement tes t N/A
4.8.4.4 Drop test N/A
4.8.4.5 Impact test N/A
4.8.4.6 Crush test N/A
4.8.5 Compliance N/A
30N force test with test probe N/A
20N force test with test hook N/A
4.9 Likelihood of fire or shock due to entry of conductive object
N/A
4.10 Component requirements
N/A
4.10.1 Disconnect Device N/A
4.10.2 Switches and relays No such component is used N/A
5 ELECTRICALLY - CAUSED INJURY
P
5.2 Classification and limits of electrical energy sources
P
5.2.2 ES1, ES2 and ES3 limits ES1 P