coolant capacity SSANGYONG NEW ACTYON SPORTS 2013 Service Manual
[x] Cancel search | Manufacturer: SSANGYONG, Model Year: 2013, Model line: NEW ACTYON SPORTS, Model: SSANGYONG NEW ACTYON SPORTS 2013Pages: 751, PDF Size: 72.63 MB
Page 24 of 751
01-70000-00
1) Service Interval
2) Specification and Capacity
Engine oilSpecification Quality class: Ssangyong genuine engine oil (Total Quartz INEO ECS
5W 30, SK ZIC SY 5W 30) or oil Approved by MB Sheet 229.51
Capacity approx. 6.0 litter
Engine
coolantSpecification Ssangyong genuine coolant Anti-Freeze SYC-1025
Capacity approx. 8.5 litter
Severe condition
Frequent stop-and-go traffic, extended idling, short driving distance below 6 km, driving distance below
16 km when the outside temperature remains below freezing
Driving in a hilly or mountainous terrain, sandy, or dusty area
High load driving such as trailer towing
Taxi, patrol service or delivery service (extended idling and excessive driving with low speed) -
-
-
-
DescriptionDaily
inspectionWeekly
inspectionService interval
Engine oil & oil
filterInspection - EU Change every 20,000 km or 12 months
(The service interval should be shortened
under severe conditions)
General Change every 15,000 km or 12 months
(The service interval should be shortened
under severe conditions)
Coolant Inspection - Change every 200,000 km or 5 years
Air cleaner
element- Inspection Diesel EU Change every 20,000 km (The
service interval should be
shortened under severe
conditions)
General Clean every 7,500 km, change
every 15,000 km (The service
interval should be shortened
under severe conditions)
Gasoline Clean every 15,000 km, replace every
60,000 km (The service interval should be
shortened under severe conditions)
Fuel filter - - EU Change every 40,000 km (Draining water
from fuel filter: whenever replacing the
engine oil)
General Change every 45,000 km (Draining water
from fuel filter: whenever replacing the
engine oil)
Page 141 of 751
08-31520-00
1. SPECIFICATION
Unit Description Specification
Cooling system Type Water cooling, forced circulation
Coolant Capacity approx. 8.5 L
Radiator Core size 555W x 582.4H x 27T (over 326,250mm2)
Flow type Cross flow
Min. cooling capacity over 68,000 kcal/h
Antifreeze Type SYC1025 (Long life coolant)
Mixing ratio
(water:antifreeze)50 : 50
Cooling fan module Type Electric
CapacityØ472 x 400W x 5B
Control type PWM type
Coolant reservoir Capacity over 1.5 L
Circulation Closed roof type
Pressure cap Screw type, 1.4bar
Vacuum valve Screw type, 1.4bar
Thermostat Type Wax pallet type
Opening temperature90˚C
Fully open temperature100˚C
Valve lift 8 mm
Page 229 of 751
15-290000-00
(9) EGR control
A. Overview
The EGR (Electric-Exhaust Gas Recirculation) valve reduces the NOx emission level by recirculating
some of the exhaust gas to the intake system.
To meet Euro-V regulation, the capacity and response rate of E-EGR valve in D20DTR engine have
been greatly improved. The EGR cooler with high capacity reduces the Nox, and the bypass valve
reduces the CO and HC due to EGR gas before warming up.
Also, the engine ECU adjusts the E-EGR opening by using the air mass signal through HFM sensor. If
the exhaust gas gets into the intake manifold when the EGR valve is open, the amount of fresh air
through HFM sensor should be decresed.
B. Components
E-EGR cooler
Accelerator pedal
moduleD20DTR ECU
Coolant
temperature
sensorOxygen sensor
HFM (intake air
temperature)Electric throttle
body
Crankshaft
position sensorE-EGR valve
T-MAP sensor
Page 242 of 751
15-42
Relay box in engine compartment
(13) PTC heater control
A. Overview
The supplementary electrical heater is installed in DI engine equipped vehicle as a basic equipment. The
PTC system is operated according to two temperature values measured at the coolant temperature
sensor and HFM sensor. This device is mounted in the heater air outlet and increase the temperature of
air to the passenger compartment. Because PTC system is heated by electrical power, high capacity
alternator is required. PTC does not operate during engine cranking, while the battery voltage is lower
than 11 V or during preheating process of glow plugs.
B. Components
HFM (intake air
temperature)
Coolant temperature
sensorPTC heater
PTC 2 relay (PTC
heater 2, 3)
PTC heater
3 (40A)
PTC heater
2 (40A)
PTC heater
1 (40A)
D20DTR ECU
PTC 1 relay
(PTC heater 1)
Page 283 of 751
06-32110-01
1. GENERAL SPECIFICATIONS
Application Gasoline engine
Cooling system Type Water cooling forced circulation
Coolant Capacity 11.3L
Thermostat Type Wax Pellet Type
Initial Opening Temp.87℃(188.6℉)
Fully Opening Temp.102℃(215.6℉)
Fully Closing Temp.85℃(187℉)
Stroke 7mm
Cooling fan module Type Electric
CapacityΦ472 x 400W x 5B
Control type PWM type
Coolant reservoir Capacity over 1.5L
Circulation Closed roof type
Pressure cap Screw type, 1.4bar
Vacuum valve Screw type, 1.4bar
Water pump Type Turbo centrifugal
Impeller diameter 65mm
Impeller blades 8
Radiator Core size555W x 582.4H x 27T (over 326,250mm²)
Flow type Cross flow
Min. cooling capacity over 68,000kcal/h
Coolant temperature
gaugeMinimum radiation capability 45,000kcal/h
Resistance(50℃(122℉)) 185.2Ω
Resistance(80℃(176℉)) 47.4Ω
Resistance(105℃(221℉)) 28.2Ω